This study focuses on techno-economic and environmental feasibility study of a hybrid grid connected wind/PV/biomass energy system for Marmara University Goztepe Campus in Istanbul. HOMER software is used to determine the optimum size of the equipment, based on the geographical and meteorological data of the campus. According to the simulation results, the energy system with the minimum net present cost (NPC) and cost of energy (COE) is chosen as the optimum system. Besides, this study aims to reduce greenhouse gas emissions, polluting the air by using renewable resources. Because of negative impacts of the fossil fuels on human health and environment, all the energy sources for this system are renewable energies which have less pollution. In the simulation, PV, wind, and biomass energy resources are used, but the optimum hybrid energy system is determined as grid connected wind/biomass system consisting of 1000 kW grid, 1000 kW biomass generator, and 1500 kW wind turbine. The NPC of the optimum system is calculated as $5.612.501 while the COE is 0,067$/kW. The system also decreases the emissions of greenhouse gases.
1 April 2019 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
This paper presents a techno-economic analysis of hybrid renewable energy systems to supply the electrical load requirements of the nursing home located in Istanbul, Turkey. The standalone hybrid renewable energy systems (Photovoltaic (PV)/wind/fuel cell/electrolyzer, PV/fuel cell/electrolyzer, and wind/fuel cell/electrolyzer, etc.) considered in the analysis were comprised of different combinations of PV panels, fuel cells, and wind turbines supplemented with hydrogen storage. In this study, the Hybrid Optimization of Multiple Energy Resources (HOMER) software is used as the assessment tool to determine the optimal configuration of hybrid renewable energy systems taking total net present cost and cost of energy into consideration. As a result, it is determined that the optimal system configuration of standalone wind/PV/fuel cell/electrolyzer hybrid renewable energy systems with the lowest total net present cost consists of 30 kW PV panel, 20 kW wind turbine, 20 kW fuel cell, 20 kW power converter, 50 kW electrolyzer, 20 kW rectifier, and 100 kg hydrogen tank. Besides, the net present cost and cost of energy of the optimum configuration are calculated to be $607,298 and $1.306/kWh, respectively. The system is considered as completely renewable. When wind speed and solar radiation values increase, then the cost of energy decrease about $0.979/kWh.
The worldwide use of clean and environmentally friendly renewable energy sources, has been increasing to prevent global warming and climate change. In this study, a hybrid renewable energy system (HRES) including biomass and solar as the source, has been investigated for Mehmet Akif Ersoy University Istiklal Campus in Burdur, Türkiye. The campus has an animal farm consisting of 300 cattle and 200 sheep. Therefore, manure of the animals will be used as the resource for biomass generation. HOMER software is used to simulate the system and to find the size and the quantity of the equipment according to the meteorological and biomass capacity of the campus. The optimum system is determined by means of net present cost (NPC) and the cost of energy (COE). In the simulation, wind energy is also investigated but since the wind speed is not sufficient to produce energy in the region, it is not considered in the optimum system. The optimum system is determined to be grid connected biomass-solar system with 5000 kW PV panels and a 1500 kW biomass generator assisted by the grid of 3000 kW. Also, the NPC of the system is estimated to be USD 18.800.000 and the COE for the system is calculated as 0,107 USD/kWh. The system also reduces the emissions causing the global warming.
Proportional-Integral-Derivative (PID) controllers remain a widely adopted solution in the field of control systems due to their simplicity, flexibility, and ability to control a wide range of processes. Despite their success in various applications, PID tuning remains a persistent challenge during implementation. This challenge becomes even more complex when PID controllers are implemented in discrete form, which is essential for most digital control systems. The discretization of continuous-time PID controllers introduces an additional layer of complexity, generating a wide range of possible discrete PID structures and leading to an inefficient selection process. This study proposes a novel approach for automating the tuning of discrete PID controllers by integrating a generalized discrete PID structure, named FiFNF, with Particle Swarm Optimization (PSO). The generalized structure offers flexibility in discretization, enabling automatic selection from 18 different discrete PID configurations derived from combinations of three discretization methods: Forward Euler Approximation, Backward Euler Approximation, and Trapezoidal Approximation. Instead of manually selecting a discretization method for the integral and derivative components, this approach provides a unified structure that supports versatile and effective discrete PID implementations. Simulation studies in MATLAB and Simulink have been conducted to test and validate the proposed PID design. Moreover, a comparative analysis is presented between FiFNF and the conventional backward PID configuration, with both configurations tuned using PSO.
30 September 2024 in Balkan Journal of Electrical and Computer Engineering
This study explores the integration of renewable energy sources, namely, solar and wind, focusing on strategies to optimize their deployment into the electrical grid, and increasing the resiliency of the grid. Using four-year comprehensive data from Spain, including energy consumption, generation, pricing, and the condition of the weather, advanced statistical analysis, regression models, and optimization methods have been employed. Based on the results, it is clear that solar energy is seasonal, and wind energy is variable, with the weather playing a considerable role in the energy output. The optimization analysis showed that when the renewable capacity was increased to include 30 MW of solar and 120 MW of wind, the energy demand would be met at a significantly lower total system cost of $12.60 per unit. The costs related to operation and emissions would also decrease notably. However, with the regression models giving modest values of R² equal to 0.19 for solar and R² equal to 0.21 for wind, the extent of these developments and prediction can be fairly modest. Still, these results provide a strong backbone for the prediction of energy generation and show that modernization of the grid and adaptive management are of crucial importance. The results of the study could provide a guideline for policymakers and energy managers on how these goals can be achieved.
Somalia–Turkish Training and Research Hospital in Mogadishu, is only powered by diesel generator currently. In this paper, the energy demand of this hospital is utilized by determining the optimum hybrid renewable energy generating system. By HOMER, a sensitivity analysis has been made with emphasis on three significant variables such as average wind speed, present diesel price, and solar radiation. From the results, it can be said that an optimum system is the standalone wind-diesel-battery storage Hybrid Renewable Energy System (HRES) with the configuration of 1,000 kW wind turbine, 350 kW diesel generator, 250 kW power converters, and 300 batteries. Additionally, the net present cost of the optimum system is calculated to be $5,056,700 and its cost of energy is estimated to be 0.191 $/kWh. The present cost of energy for Somalia is 0.5 $/kWh. This shows that the energy cost for the proposed HRES is cheaper than the conventional one. Lastly, according to the results, it is clear that the wind–diesel–battery storage HRES seems more environment friendly than other HRESs.