Emilio Carlos Piesciorovsky

Dr. Emilio Carlos Piesciorovsky

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
EPEmilio Piesciorovsky
Emilio Piesciorovsky
NSNoel N. Schulz
Noel N. Schulz
Utilities have installed distributed generators to improve reliability of the power distribution system. Distributed generators at various sites provide additional circuit paths in case energy provision to the end user is interrupted by a blackout or equipment failure. When the microgrid is working on island and grid‐connected modes, overcurrent protections in power lines must be adjusted to different distributed generator circuit paths and feeder fuses in the microgrid. This study presents an adaptive overcurrent protection that integrates technical and economic advantages of fuses and relays in a microgrid with distributed generators. This fuse relay adaptive overcurrent protection (FRAOP) scheme protects power lines and feeders by grouping identical inverse time overcurrent settings of relays, and logic gates of relay's breakers. Selectivity, reliability, and speed of the FRAOP was verified by a real‐time simulator with relays in‐the‐loop.

3 June 2024 in IEEE Open Journal of the Industrial Electronics Society
Verified
Journal Article
Open access
MFMaximiliano Ferrari
Maximiliano Ferrari
LTLeon M. Tolbert
Leon M. Tolbert
EPEmilio Piesciorovsky
Emilio Piesciorovsky
Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this paper is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line and three-phase electrical faults.

4 August 2023 in Energy Reports
Verified
Journal Article
Open access
EPEmilio Piesciorovsky
Emilio Piesciorovsky
GHGary Hahn
Gary Hahn
RHRaymond Charles Borges Hink
Raymond Charles Borges Hink
AWAaron Werth
Aaron Werth
ALAnnabelle Lee
Annabelle Lee

15 May 2020 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
EPEmilio Piesciorovsky
Emilio Piesciorovsky
TSTravis Smith
Travis Smith
TOThomas Benjamin Ollis
Thomas Benjamin Ollis

30 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
EPEmilio Piesciorovsky
Emilio Piesciorovsky
RHRaymond Charles Borges Hink
Raymond Charles Borges Hink
AWAaron Werth
Aaron Werth
GHGary Hahn
Gary Hahn
ALAnnabelle Lee
Annabelle Lee
YPYarom Polsky
Yarom Polsky
Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small-measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible troubleshooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

26 December 2018 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
EPEmilio Piesciorovsky
Emilio Piesciorovsky
MMMaximiliano F. Ferrari Maglia
Maximiliano F. Ferrari Maglia