In this paper, the micro-channel flat-plate heat pipes-based BIPV/T system has been proposed, which is expected to have the characteristics, e.g. reduced contact thermal resistance, enhanced heat transfer area, improved heat transfer efficiency and building integration. The proposed system was constructed at the laboratory of Guangdong University of Technology (China) to study its performance. The temperatures of the glass cover, PV panel, micro-channel flat-plate heat pipes, and tank water were measured, as well as the ambient temperature. The thermal and electrical efficiency was also calculated for the system operated under the conditions with different simulated radiations and water flow rates. It was found that the proposed system can achieve the maximum average overall efficiency of 50.4% (thermal efficiency of 45.9% and electrical efficiency of 4.5%) for the simulated radiation of 300 W/m 2 and water flow rate of 600 L/h. By comparing the proposed system with the two previous systems employing the conventional heat pipes, the thermal efficiency of the proposed system was clearly improved. The research will develop an innovative BIPV/T technology possessing high thermal conduction capability and high thermal efficiency compared with the conventional BIPV/T system, and helps realise the global targets of reducing carbon emission and saving primary energy in buildings. Practical application: This novel BIPV/T employing micro-channel flat-plate heat pipes will be potentially used in buildings to provide amount of electricity and thermal energy. The generated electricity will be used by the residents for electrical devices, and the thermal energy can be used for hot water, even for space heating and cooling.
In this paper, a solar-powered dehumidification window (SPDW), combining a conventional double-glazed building window with a solid desiccant packed bed and a photovoltaic panel, has been proposed to dehumidify the air supplied to a residential building in an energy-saving way. The solid desiccant packed bed was installed between the double layers of the residential window to achieve the compact building-integrated window-dehumidifying system that could be regenerated by solar energy, and the photovoltaic panel was used to compensate the electricity for the operation of the fans to supply the air to the building. To investigate the dehumidification and regeneration performance of the SPDW, the transient moisture removal, dehumidification efficiency, temperature difference between the building inlet and outlet air, heat transfer characteristics, desiccant temperature, regeneration rate, and the power of the fans and the photovoltaic panel were analysed for different inlet air conditions and simulated solar radiation. It was found that, for the system operated under an inlet air temperature of 19.2 °C and a relative humidity of 86.1% during the dehumidification process, the system performed with a maximum transient moisture removal of 7.1 g/kg, a maximum dehumidification efficiency of 58.60%, a maximum temperature difference between the inlet and outlet air of 10.7 °C, and a maximum released adsorption heat absorbed by the dehumidified air of 89.66%. In the regeneration process, the system performed with a maximum desiccant temperature of 35.3 °C, a maximum regeneration rate of 153 g/h, and a maximum power of the photovoltaic panels of 39.83 W under the simulated solar radiation of 900 W/m2. The results from the established semi-empirical model agreed well with the testing results, and the model could be used to predict the water content ratio of the desiccant modules during the dehumidification process under different conditions, which will be helpful in the analysis and application of the SPDW in the future.
In this paper, a novel solar solid dehumidification/regeneration bed has been proposed, and its three regeneration methods, i.e., simulated solar radiation regeneration, microwave regeneration, and combined regeneration of the microwave and simulated solar radiation, were experimentally investigated and compared, as well as the dehumidification performance. The degree of regeneration of the proposed system under the regeneration method combining both microwave irradiation and simulated solar radiation could reach 77.7%, which was 3.77 times higher than that of the system under the simulated solar regeneration method and 1.05 times higher than that of the system under the microwave regeneration. The maximum energy efficiency of the proposed system under the combined regeneration method was 21.7%, while it was only 19.4% for the system under microwave regeneration. All these proved that the combined regeneration method of the simulated solar and microwave radiation not only improved the regeneration efficiency of the system, but also enhanced the energy efficiency. For the dehumidification performance, the maximum transient moisture removal was 14.1 g/kg, the maximum dehumidification efficiency was 68.0% and the maximum speed of dehumidification was 0.294 g/(kg·s) when the inlet air temperature was at 26.09 °C and the air relative humidity was at 89.23%. By comparing the testing results with the semi-empirical results from the Page model, it was indicated that the Page model can predict the regeneration characteristics of the novel solar solid dehumidification/regeneration bed under the combined method of microwave and simulated solar regeneration. The results of this research should prove useful to researchers and engineers to exploit the potential of solar technologies in buildings worldwide.
In this paper, the solid desiccant adsorption packed bed with a three-stage internal cooling (ICSPB) has been proposed to improve the dehumidification efficiency and make a comparison with that of non-internal cooling. To investigate the performance of the ICSPB, the dehumidification capacity, dehumidification efficiency, water content of solid desiccant, moisture ratio of solid desiccant, temperature of solid desiccant and inlet and outlet air temperature difference were discussed in different conditions of inlet air and supplying water temperature. It was found that the dehumidification performance of the bed with internal cooling could be improved greatly in the low temperature and low humidity conditions, while in the high temperature and humid, the improvement was not obvious. With internal cooling, the dehumidification efficiency and the water content of the solid desiccant could be improved 59.69% and 110.7%, respectively, and the temperature of solid desiccant could be reduced 2.2 °C when the ICSPB operated at the inlet air temperature of 20 °C, inlet humidity of 55%, and water temperature of 14 °C. Moreover, the dehumidification performance at each stage of ICSPB was studied. It was found that, the first stage played the most important role in the dehumidification process. In addition, the calculation models that can be used to predict the moisture ratio and the temperature of solid desiccant were established on the test results.
18 June 2020 in International Journal of Low-Carbon Technologies
In this paper, a novel micro-channel flat loop heat pipe (MC-FLHP) for data center cooling and heat recovery is proposed, which has the following novelties and distinguished advantages, i.e., a tightly attached flat heat pipes array with IT server thus reaching a ‘server level’ cooling for data center, several pre-set micro-grooves which increases the convective heat transfer coefficient, and a separated evaporator-condenser which greatly improves the flexibility of the system’s installation. The proposed system with R134a (filling ratio of 30%) as the working fluid is designed, constructed and tested, and the testing results are used to evaluate its thermal recovery efficiency and its impact factors, i.e., simulated heat load, cooling water inlet temperature and height difference between the evaporator and condenser. Under the range of test conditions (e.g., simulated heat load from 500 W to 3000 W, cooling water inlet temperature from 15°C to 24°C, height difference from 0.6 m to 1.0 m), the overall thermal recovery efficiency is in the range 57.34% to 84.52%. It is found that under the specific operational conditions with the simulated heat load of 500 W, cooling water inlet temperature of 15°C, and height difference between the evaporator and the condenser of 0.8 m, a peak thermal recovery efficiency of 84.52% is achieved. This study can help achieve the global goals of green and sustainable data center, and also save data center energy consumption and thus operational costs.