Libin Zhu

Libin Zhu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2017 in Lipids in Health and Disease
Verified
Journal Article
Open access
PDF file
ZXZhaobo Xia
Zhaobo Xia
YHYijiang Han
Yijiang Han
KWKe Wang
Ke Wang
SGShikun Guo
Shikun Guo
DWDazhou Wu
Dazhou Wu
LZLibin Zhu
Libin Zhu
Propionic acid is a three-carbon short chain fatty acid (SCFA) that has various effects on colonic functions. Although several studies have shown the effects of propionic acid on intestinal mucosal barrier function, studies of the promotion effect during pre-weaning are rare in the literature as far as we know. Pre-weaning male Sprague-Dawley rats 7 days after birth were given an oral 0.2 mL/10 g of 200 mM propionic acid solution in the propionic acid group or normal saline solution in the control group by gavage twice a day for ten days. The proximal colonic contents were used for extraction and determination of propionic acid by gas chromatographic analysis; the transepithelial electrical resistance (TER) of colonic tissue was detected by an Ussing chamber; the alterations of ZO-1, Claudin-1, Claudin-8 and Occludin proteins were analyzed by Western blot and immunohistochemistry; and The activity of ERK and p38 MAPK was determined by the phosphorylation status of ERK1/2 and p38 with Western blot. Our results suggested a higher concentration (23.5 ± 1.9 mmol/kg) of propionic acid compared to the physiological concentration (18.1 ± 0.9 mmol/kg) in colonic contents after oral administration increased the value of TER and the expression of ZO-1, Claudin-1, Claudin-8 and Occludin compared to the control group. Furthermore, the expression levels of phosphorylated ERK1/2 and p38 MAPK were increased in propionic acid group. We concluded that continuous oral administration of propionic acid during lactation may increase its concentration in the proximal colon and promote epithelial barrier function of proximal colon by enhancing the expression of ZO-1, Claudin-8, Claudin-1 and Occludin via increases in the expression of ERK1/2 and p38 MAPK.

21 June 2023 in Photonics
Verified
Journal Article
Open access
PDF file
LZLechao Zhang
Lechao Zhang
YZYao Zhou
Yao Zhou
DHDanfei Huang
Danfei Huang
LZLibin Zhu
Libin Zhu
XCXiaoqing Chen
Xiaoqing Chen
XCXiaojing Chen
Xiaojing Chen
Obtaining adequate resection margins in small intestinal necrotic tissue remains challenging due to the lack of intraoperative feedback. Here, we used hyperspectral imaging (HSI), an imaging technique for objective identification, combined with deep learning methods for automated small intestine tissue classification. As part of a prospective experimental study, we recorded hyperspectral datasets of small intestine biopsies from seven white rabbits. Based on the differences in the spectral characteristics of normal and ischemic necrotic small intestinal tissues in the wavelength range of 400–1000 nm, we applied deep learning techniques to objectively distinguish between these two types of tissues. The results showed that three-dimensional convolutional neural networks were more effective in extracting both spectral and spatial features of small intestine tissue hyperspectral data for classification. The combination of a deep learning model and HSI provided a new idea for the objective identification of ischemic necrotic tissue in the small intestine.

23 April 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
JYJiaXuan Yan
JiaXuan Yan
YXYi Xie
Yi Xie
XCXiaojing Chen
Xiaojing Chen
YYYuShi Yang
YuShi Yang
LZLibin Zhu
Libin Zhu
DHDanfei Huang
Danfei Huang
Multispectral imaging (MSI) systems leverage the differing optical absorption properties of oxygenated and deoxygenated haemoglobin across various wavelengths to enable non-invasive dynamic monitoring of relative blood oxygen saturation. Existing systems struggle to meet demands for portable, efficient monitoring due to high costs and slow response times. This study developed a compact MSI system utilising a multi-band light-emitting diode array as its light source. Combined with a triple-isosbestic point calibration algorithm, it rapidly generates pseudo-colour maps of blood oxygen distribution. The system was validated in human finger and rabbit small intestine ischemia–reperfusion models. Following occlusion, relative blood oxygen saturation in the ischaemic regions decreased to 66.3% (finger) and 29.5% (small intestine), both significantly distinct from normal areas. Post-reperfusion, the ischaemic regions exhibited marked recovery with characteristic reperfusion response patterns. These findings demonstrate the system’s capability to accurately identify hypoxemic zones, indicating its potential for dynamic in vivo blood oxygen monitoring applications.

12 October 2019 in Iranian Journal of Pediatrics
Verified
Journal Article
Open access
PDF file
FSFang Bin Shao
Fang Bin Shao
XBXiao Zhou Bao
Xiao Zhou Bao
JWJun Wang
Jun Wang
ZLZhong Rong Li
Zhong Rong Li
LZLibin Zhu
Libin Zhu
The survival rate of neonatal giant omphaloceles has improved over the past 10 years, but the mortality rate remains at approximately 50% with traditional t ...