donghun Han

Mr. donghun Han

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KLKANG-HEE LEE KANG-HEE LEE
KANG-HEE LEE KANG-HEE LEE
JCJun woo Choi
Jun woo Choi
CPChun Oh Park
Chun Oh Park
DHdonghun Han
donghun Han
MKMin-Soo Kang
Min-Soo Kang
In this study, the development of a deep learning approach for distinguishing cardiomegaly in chest X-ray images and its validation process are presented. Typically, radiologists diagnose cardiomegaly by examining X-ray images. However, their interpretations can vary owing to subjective judgments, and mild cardiomegaly can be missed. For this reason, there is ongoing research into the use of AI-based deep learning algorithms as an adjunct to X-ray interpretation. In this study, radiologists collected 10,000 public images, from which 718 useful images were selected to create a dataset. A DenseNet121 algorithm was then used to develop an AI model for cardiomegaly detection. The results demonstrate an accuracy of 0.95, a recall of 0.91, and an F1 score of 0.94. Additional validation was performed to ensure the accuracy of the cardiomegaly detection model. The validation methods included saliency maps and guided backpropagation, which indicated the significance of the model. In conclusion, this study demonstrates the potential to develop a high-quality AI model with fewer data than previous studies, suggesting its applicability in the medical field.

9 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DHdonghun Han
donghun Han
YJYeong-Hoon Jeong
Yeong-Hoon Jeong
MKMin-Soo Kang
Min-Soo Kang
In this study, we demonstrate the viability of applying artificial intelligence (AI) techniques to conduct inspections at the OLED cell level using simulated data. The implementation of AI technologies necessitates training data, which we addressed by generating an OLED dataset via our proprietary A2G algorithm, integrating the finite element method among concerns over data security. Our A2G algorithm is designed to produce time-dependent datasets and establish threshold conditions for the expansion of dark spots based on OLED parameters and predicted lifespan. We explored the potential integration of AI in the inspection phase, performing cell-based evaluations using three distinct convolutional neural network models. The test results yielded a promising 95% recognition rate when classifying OLED data into pass and fail categories, demonstrating the practical effectiveness of this approach. Through this research, we not only confirmed the feasibility of using simulated OLED data in place of actual data but also highlighted the potential for the automation of manual inspection processes. Furthermore, by introducing OLED defect detection models at the cell level, as opposed to the traditional panel level during inspections, we anticipate higher classification rates and improved yield. This forward-thinking approach underscores significant advancement in OLED inspection processes, indicating a potential shift in industry standards.

8 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MCMyoung-Su Choi
Myoung-Su Choi
DHdonghun Han
donghun Han
JCJun woo Choi
Jun woo Choi
MKMin-Soo Kang
Min-Soo Kang
Sleep apnea has emerged as a significant health issue in modern society, with self-diagnosis and effective management becoming increasingly important. Among the most renowned methods for self-diagnosis, the STOP-BANG questionnaire is widely recognized as a simple yet effective tool for diagnosing and assessing the risk of sleep apnea. However, its sensitivity and specificity have limitations, necessitating the need for tools with higher performance. Consequently, this study aimed to enhance the accuracy of sleep apnea diagnoses by integrating machine learning with the STOP-BANG questionnaire. Research through actual cases was conducted based on the data of 262 patients undergoing polysomnography, confirming sleep apnea with a STOP-BANG score of ≥3 and an Apnea–Hypopnea Index (AHI) of ≥5. The accuracy, sensitivity, and specificity were derived by comparing Apnea–Hypopnea Index scores with STOP-BANG scores. When applying machine learning models, four hyperparameter-tuned models were utilized: K-Nearest Neighbor (K-NN), Logistic Regression, Random Forest, and Support Vector Machine (SVM). Among them, the K-NN model with a K value of 11 demonstrated superior performance, achieving a sensitivity of 0.94, specificity of 0.85, and overall accuracy of 0.92. These results highlight the potential of combining traditional STOP-BANG diagnostic tools with machine learning technology, offering new directions for future research in self-diagnosis and the preliminary diagnosis of sleep-related disorders in clinical settings.

21 November 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
JCJun woo Choi
Jun woo Choi
WRWon Lo Rhee
Won Lo Rhee
DHdonghun Han
donghun Han
MKMin-Soo Kang
Min-Soo Kang
Background/Objectives: This study demonstrates improved generalization in pressure-ulcer stage classification. In medical imaging, training data are often scarce and disease specific. For skin conditions such as pressure ulcers, variation in camera to subject distance, resolution, illumination, and viewpoint across photographers reduces accuracy in clinical use. Methods: We developed a YOLOv7-based pressure ulcer stage classification model by employing a two-phase training strategy. Phase 1 was trained on the full dataset stratified by pressure-ulcer stage. Phase 2 was trained in saliency-guided images augmented with clinically plausible noise, including healing areas and white keratin. The added dataset comprised 296 images obtained by randomly sampling 30% from stages 1 through 3 of the full dataset. Results: The accuracy of the 38 newly acquired hospital images increased from 75% in Phase 1 to 89% in Phase 2. Five-fold cross-validation demonstrated stable performance (mAP@0.5: 86.20% ± 2.28%), confirming reproducibility. This exceeds by more than five percentage points the performance reported for pressure-ulcer staging models in prior studies conducted in clinical deployment settings. Conclusions: These findings suggest that curriculum learning combined with noise-enriched augmentation can improve generalization in clinical environments. Our results demonstrate that clinically informed data augmentation is a key factor in enhancing the model’s clinical generalization. Accordingly, the proposed approach provides a practical path to enhancing clinical usability in data-limited medical imaging.

2 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
SJSang Hyun Jang
Sang Hyun Jang
CIChunhwa Ihm
Chunhwa Ihm
JCJun woo Choi
Jun woo Choi
DHdonghun Han
donghun Han
KBKyunghwa Bae
Kyunghwa Bae
MKMin-Soo Kang
Min-Soo Kang
Background/Objectives: Pressure injury stage classification was performed using object detection models to address inconsistencies in clinical assessment due to variability in nurses’ experience and education levels. Methods: A dataset of 1282 pressure injury images from a medical institution was used to train and compare five representative architectures, YOLOv5x, YOLOv7, YOLOv8x, YOLOv8n, and YOLOv11x, and Faster R-CNN across Stages 1–4, excluding Deep Tissue Injury and unclassified cases. A mobile application incorporating YOLOv7 was deployed at Eulji University Daejeon Medical Center and tested by 10 nurses over 2 weeks, processing 46 cases. Results: YOLOv7 demonstrated superior performance with mAP@0.5 of 0.97 and mAP@0.5:0.95 of 0.68, achieving 93% accuracy for Stage 2 classification, the most challenging diagnostic category. Clinical validation demonstrated 87% diagnostic accuracy, 4.0/5 user satisfaction, and workflow improvement with assessment time reduced from 4–6 min to 1 min. The application proved valuable as both a diagnostic support tool and educational resource for novice nurses, with zero critical misclassifications recorded. Conclusions: This study establishes the practical utility of AI-based pressure injury classification systems in clinical practice and their potential for enhancing nursing competency and workflow efficiency.

25 June 2025 in Korean Journal of Otorhinolaryngology-Head and Neck Surgery
Verified
Journal Article
Open access
PDF file
MKMin-Soo Kang
Min-Soo Kang
DHdonghun Han
donghun Han
MKMin Woo Kim
Min Woo Kim
MCMyoung Su Choi
Myoung Su Choi
Background and Objectives The purpose of this study was to determine whether smartwatch (SW) data measured over several nights at home could effectively predict obstructive sleep apnea (OSA).Subjects and Method Patients suspected of having OSA and scheduled for polysomnography (PSG) were asked to wear a SW at home for 7 nights before undergoing PSG. After obtaining the SW data, it was compared and analyzed with the PSG.Results A total 59 people including 42 OSA patients and 17 normal control were included in the study. The sensitivity and specificity for predicting apnea-hypopnea index (AHI) ≥5/h using the SW lowest oxygen saturation of 85% were 85.7% and 70.6%. The area under curve (AUC) for the receiver operating characteristic (ROC) curve was 0.901 (p<0.001). The sensitivity and specificity for predicting AHI ≥15/h using the SW lowest oxygen saturation of 82% were 80.6% and 67.9%. The AUC for the ROC curve was 0.866 (p<0.001).Conclusion This study showed that the OSA can be predicted fairly accurately using data obtained from wearing a SW for several nights in an environment similar to daily life rather than a hospital laboratory.