SYED ZUBAIRUDDIN AHMED

Dr. SYED ZUBAIRUDDIN AHMED

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
KAKhalid Almulhim
Khalid Almulhim
MSMariam Raza Syed
Mariam Raza Syed
NANorah AlQahtani
Norah AlQahtani
MAMarwah Alamoudi
Marwah Alamoudi
MKMaria Khan
Maria Khan
Abdul Samad KhanAbdul Samad Khan
Abdul Samad Khan
Over time, much attention has been given to the use of bioceramics for biomedical applications; however, the recent trend has been gaining traction to apply these materials for dental restorations. The bioceramics (mainly bioactive) are exceptionally biocompatible and possess excellent bioactive and biological properties due to their similar chemical composition to human hard tissues. However, concern has been noticed related to their mechanical properties. All dental materials based on bioactive materials must be biocompatible, long-lasting, mechanically strong enough to bear the masticatory and functional load, wear-resistant, easily manipulated, and implanted. This review article presents the basic structure, properties, and dental applications of different bioactive materials i.e., amorphous calcium phosphate, hydroxyapatite, tri-calcium phosphate, mono-calcium phosphate, calcium silicate, and bioactive glass. The advantageous properties and limitations of these materials are also discussed. In the end, future directions and proposals are given to improve the physical and mechanical properties of bioactive materials-based dental materials.

8 June 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Abdul Samad KhanAbdul Samad Khan
Abdul Samad Khan
YAYasmin Alhamdan
Yasmin Alhamdan
HAHala Alibrahim
Hala Alibrahim
KAKhalid Almulhim
Khalid Almulhim
MNMuhammad Nawaz
Muhammad Nawaz
ISIntisar Ahmad Siddiqui
Intisar Ahmad Siddiqui
This study aimed to evaluate the incorporation of zirconia/silver phosphate nanoparticles to develop experimental dental adhesives and to measure their physical and mechanical properties. The nanoparticles were synthesized by the sonication method, and the phase purity, morphological pattern, and antibacterial properties with Staphylococcus aureus and Pseudomonas aeruginosa were assessed. The silanized nanoparticles were incorporated (0, 0.15, 0.25, and 0.5 wt.%) into the photoactivated dimethacrylate resins. The degree of conversion (DC) was assessed, followed by the micro-hardness and flexural strength/modulus test. Long-term color stability was investigated. The bond strength with the dentin surface was conducted on days 1 and 30. The transmission electron microscopy and X-ray diffractogram confirmed the nano-structure and phase purity of the particles. The nanoparticles showed antibacterial activities against both strains and inhibited biofilm formation. The DC range of the experimental groups was 55–66%. The micro-hardness and flexural strength increased with the concentration of nanoparticles in the resin. The 0.5 wt.% group showed significantly high micro-hardness values, whereas a non-significant difference was observed between the experimental groups for flexural strength. The bond strength was higher on day 1 than on day 30, and a significant difference was observed between the two periods. At day 30, the 0.5 wt.% showed significantly higher values compared to other groups. Long-term color stability was observed for all the samples. The experimental adhesives showed promising results and potential to be used for clinical applications. However, further investigations such as antibacterial, penetration depth, and cytocompatibility are required.

22 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Abdul Samad KhanAbdul Samad Khan
Abdul Samad Khan
BABashayer Ghazi AlDahlan
Bashayer Ghazi AlDahlan
NMNusaybah Hamza Maghrabi
Nusaybah Hamza Maghrabi
HAHind Waleed Albilali
Hind Waleed Albilali
SYED ZUBAIRUDDIN AHMEDSYED ZUBAIRUDDIN AHMED
SYED ZUBAIRUDDIN AHMED
ATAhmed Talal
Ahmed Talal

24 August 2024 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
FNFayez Hussain Niazi
Fayez Hussain Niazi
BABadi Alotaibi
Badi Alotaibi
AAAnshad M. Abdulla
Anshad M. Abdulla
SASarah AbdulRahman AlTowayan
Sarah AbdulRahman AlTowayan
SYED ZUBAIRUDDIN AHMEDSYED ZUBAIRUDDIN AHMED
SYED ZUBAIRUDDIN AHMED
NLNorhayati Luddin
Norhayati Luddin
To assess the effect of CAD surface conditioners and their effect on Ra and SBS of tooth-colored filling material adhered to CAD surface with adhesive modified with 1 % Sep-NPs. Also, the DC of modified EA and its effect on the rheological properties. Ninety human molars with carious extension up to the middle third of occlusal dentin were included. The teeth were then arbitrarily allocated into three groups based on the type of surface conditioning received (n = 30) Group 1 (PA), Group 2 (FS laser), and Group 3 (Ery PS). Ten samples from each group underwent Ra analysis using a stylus profiler. Twenty samples from each cohort were distributed into two subcategories based on the application of unmodified EA (A) and Sep-infiltrated EA (B). Composite restoration was built followed by SBS and failure mode analysis. Scanning electron microscopy and Energy dispersive X-ray EDX were assessed of sepiolite NPs. Degree of conversion (DC) and rheological analysis of the modified adhesive and unmodified adhesive were also performed. One-way analysis of variance (ANOVA) and the Tukey post hoc test were employed to conduct comparisons between the different groups. The highest score of Ra and bond strength were displayed by Group 1B (PA + Sep-NPs filled EA) (17.32 ± 1.43 MPa) samples. Nevertheless, the lowest values were established by Group 3A (Ery-PS + EA) (13.45 ± 0.80 MPa) treated teeth. An increase in Ra resulted in a rise in SBS.DC decreased with the incorporation of 1 % Sep-NPs in EA compared to unmodified EA. Conditioning of CAD with PA and FS laser shows high surface roughness and favorable adhesion to experimental adhesive modified with 1 % Sep-NPs. Modified adhesive with 1 % Sep-NPs decreases DC and rheological properties.

5 November 2024 in Microscopy Research and Technique
Verified
Journal Article
Closed access
SYED ZUBAIRUDDIN AHMEDSYED ZUBAIRUDDIN AHMED
SYED ZUBAIRUDDIN AHMED
AKAbdul Samad Khan
Abdul Samad Khan
WNWejdan Waleed Nasser
Wejdan Waleed Nasser
MAMethayel Abdulrahman Alrushaid
Methayel Abdulrahman Alrushaid
ZAZahrah Mohammed Alfaraj
Zahrah Mohammed Alfaraj
MHMohamed Ibrahim Abu Hassan
Mohamed Ibrahim Abu Hassan

13 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
Abdul Samad KhanAbdul Samad Khan
Abdul Samad Khan
AAAlaa Alshaia
Alaa Alshaia
AAAlAnood AlDubayan
AlAnood AlDubayan
SASundus Alarifi
Sundus Alarifi
AAAbdulaziz Alamri
Abdulaziz Alamri
SRSuriya Rehman
Suriya Rehman
This study aimed to fabricate nano-hydroxyapatite (nHA) grafted/non-grafted E-glass-fiber-based (nHA/EG) and E-glass fiber (EG) orthodontic retainers and to compare their properties with commercially available retainers. Stainless-steel (SS) retainers and everStick Ortho (EST) were used as control groups. The retainers were evaluated with Raman spectroscopy and bonded to bovine teeth. The samples were fatigued under cyclic loading (120,000 cycles) followed by static load testing. The failure behavior was evaluated under an optical microscope and scanning electron microscope. The strain growth on the orthodontic retainers was assessed (48h and 168h) by an adhesion test using Staphylococcus aureus and Candida albicans. The characteristic peaks of resin and glass fibers were observed, and the debonding force results showed a significant difference among all of the groups. SS retainers showed the highest bonding force, whereas nHA/EG retainers showed a non-significant difference from EG and EST retainers. SS retainers’ failure mode occurred mainly at the retainer–composite interface, while breakage occurred in glass-fiber-based retainers. The strains’ adhesion to EST and EG was reduced with time. However, it was increased with nHA/EG. Fabrication of nHA/EG retainers was successfully achieved and showed better debonding force compared to other glass-fiber-based groups, whereas non-linear behavior was observed for the strains’ adhesion.