qing liu

Dr. qing liu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
SZShiqi Zheng
Shiqi Zheng
QLqing liu
qing liu
HFhan fengxia
han fengxia
SLShan Liu
Shan Liu
THTong Han
Tong Han
HYHao Yan
Hao Yan
To protect the environment and reduce the consumption of natural resources, this study investigated the performance of self-compacting concrete (SCC) utilizing aeolian sand (AS) as a replacement for fine aggregate and recycled coarse aggregate (RCA) as a replacement for natural coarse aggregate. Twelve mixing ratios were prepared, with AS replacement ratios at 0, 20%, 40%, and 60% and RCA replacement ratios at 0, 25%, and 50%. The evaluation primarily focused on workability, uniaxial compressive strength, split tensile strength, stress–strain curve, modulus of elasticity, and axial compressive strength. The results indicated that both AS and RCA can enhance the performance of SCC at appropriate replacement ratios, and a 20% AS and 50% RCA replacement ratio significantly improved the performance of SCC. In addition, the effects of AS and RCA replacements on SCC were evaluated by several performance indexes, which provides a basis for subsequent experimental studies and demonstrates the feasibility of incorporating AS and RCA into SCC.

25 September 2023 in Materials
Verified
Journal Article
Open access
PDF file
HYHao Yan
Hao Yan
QLqing liu
qing liu
HFhan fengxia
han fengxia
SLShan Liu
Shan Liu
THTong Han
Tong Han
BHBowen He
Bowen He
Aeolian sand (AS) and recycled coarse aggregate (RCA) can be reasonably utilized as green materials for concrete modification. The paucity of natural sand and gravel in the construction industry is anticipated to be remedied by the use of these two eco-friendly concrete ingredients. This is incredibly important for environmental protection. Study on the damage law of self-compacting concrete with the addition of AS and RCA (ARSCC) under severely cold conditions is of great significance for the promotion and implementation of this material. In this study, 12 groups of ARSCC specimens were prepared for freeze–thaw cycle experiments, with AS substitution rates of 0, 20%, 40%, and 60% as well as RCA replacement rates of 0, 25%, and 50%. Then, the degradation mechanism of ARSCC freeze–thaw damage was discussed from both macroscopic and microscopic perspectives via mass loss rate (Wn), relative dynamic modulus of elasticity (Pn), bubble spacing factor, and SEM analysis. Finally, the response surface method was utilized to determine the damage variable. A freeze–thaw damage model for ARSCC was developed based on the Weibull distribution and Grey theories. The results showed that the Pn could reflect the evolution law of the internal structure of ARSCC. Appropriate addition of AS to fill the large, harmful pores in RCA would inhibit freeze–thaw damage of ARSCC. The optimum substitution rates of AS and RCA were determined to be 20–40% and 25–50%, respectively. In addition, the values obtained from theoretical damage modeling and experiments were in good agreement. The acquired damage model had the potential to predict ARSCC damage under freeze–thaw cycles.

22 November 2023 in Materials
Verified
Journal Article
Open access
PDF file
SZShiqi Zheng
Shiqi Zheng
QLqing liu
qing liu
HFhan fengxia
han fengxia
SLShan Liu
Shan Liu
GZGuoxing Zhang
Guoxing Zhang
JZJiayan Zhu
Jiayan Zhu
Self-compacting concrete has seen extensive application in both engineering and construction. In order to save building resources, aeolian sand—recycled coarse aggregate self-compacting concrete (ARSCC) is created by partially substituting recycled coarse aggregates (RCA) and aeolian sand (AS) for natural coarse aggregates. For ten groups with different mechanical and durable properties, this study examined the effects of sulfate erosion, chloride penetration resistance, and related impermeability, as well as AS replacement ratios of 20%, 40%, and 60% and RCA replacement ratios of 25%, 50%, and 75% in ARSCC and a control group (A0-R0). According to the study’s findings, after sulfate attack, the highest relative dynamic elastic modulus and corrosion resistance factor were obtained with the 20% AS replacement ratio and 50% RCA replacement ratio (A20-R50). The highest impermeability grade and lowest electric flux were obtained with the 20% AS replacement ratio and 25% RCA replacement ratio (A20-R25). X-ray diffraction (XRD) and mercury intrusion porosimetry (MIP) revealed that the addition of aeolian sand and recycled coarse aggregates improved the pore structure of the SCC and increased the densification of the self-compacting concrete, particularly following sulfate attack. This study highlights the importance of recycled aggregates and aeolian sand in engineering applications and the sustainable growth of the concrete industry, both of which support resource conservation and environmental protection.

22 May 2024 in Materials
Verified
Journal Article
Open access
PDF file
XYXiang Yuanhang
Xiang Yuanhang
HFhan fengxia
han fengxia
QLqing liu
qing liu
This study examined the impact of sulfate and sulfate–chloride dry–wet cyclic erosion on the mechanical properties and microscopic pore structure of engineered cementitious composite (ECC) with recycled fine aggregate (RA). Uniaxial tensile tests and four-point bending tests were conducted to evaluate the mechanical properties of RAECC, while the resonance frequency ratio was used to assess the integrity of the specimens. Finally, X-ray computed tomography (X-CT) reconstruction was employed to analyze the erosion effects on the microscopic pore structure. The results showed that the uniaxial tensile strength and flexural strength of the RAECC specimens in corrosive solution first increased and then decreased, and the 5% Na2SO4 solution caused the most serious erosion of the specimens. The resonance frequency ratio of the specimens reached the peak value when they were subjected to dry–wet cycles 15 times in the 5% Na2SO4 solution. During the erosion process, the pore space of the specimen first decreased and then increased, and the number of pores increased. The erosion process is the result of the erosion products continuously filling and eventually destroying the pores, and the erosion damage produces a large number of new pores and poor sphericity, leading to a decline in mechanical properties.

26 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XZXiaojian Zhang
Xiaojian Zhang
SZShiyi Zhao
Shiyi Zhao
AJAlipujiang Jierula
Alipujiang Jierula
QLqing liu
qing liu
To investigate the influence of different connection configurations of viscous dampers on seismic mitigation performance, this study conducts a numerical simulation analysis of a 10-story inpatient building in Bazhou People’s Hospital, comparing the energy dissipation efficacy of viscous dampers under three connection types: diagonal bracing, chevron bracing, and wall-mounted connections. The results demonstrate that both chevron and wall-mounted configurations exhibit superior seismic mitigation performance compared to diagonal bracing. Specifically, chevron bracing is more suitable for mid- to high-rise structures, while wall-mounted connections achieve marginally better performance in low-rise buildings. However, the latter’s efficacy diminishes in mid- to high-rise structures due to the influence of wall self-weight. This study provides practical insights for optimizing the arrangement and application of viscous dampers in engineering projects.

15 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YNYanfeng Niu
Yanfeng Niu
HFhan fengxia
han fengxia
QLqing liu
qing liu
XYXu Yang
Xu Yang
Xinjiang is in northwest China and has abundant desert sand. Replacing natural sand with sand from deserts is an urgent need and could be used in making polyethylene fiber−engineered cementitious composite (PE−ECC). The interfacial bonding properties of desert sand PE−ECC (DSPE−ECC) were made using the optimal mix proportion (30% desert sand content, 2% fiber volume) and the laboratory’s previous research results. Normal sand PE−ECC (NSPE−ECC) and DSPE−ECC at different test ages (3, 7, 14, and 28 days) were subjected to uniaxial tensile tests, and a method for determining bonding properties is proposed. Scanning electron microscopy and X-ray diffraction were used to analyze the development of PE−ECC fiber and matrix and the formation of hydration products. The results indicated that the cracking loads of the DSPE−ECC at 3, 7, 14, and 28 days increased by 16.72%, 28%, 23.23%, and 10.05%, respectively. Desert sand had low water content and high water absorption, which slowed down the rate of C2S, C3S combining with water molecules to form C−S−H, and had a great influence on the bonding properties of ECC at 3 days. However, the bonding properties of DSPE−ECC were only slightly less than those of NSPE−ECC at 28 days, and the bonding properties had gradually stabilized. Therefore, the addition of desert sand enhanced the fiber/matrix’s bonding properties, and the bonding properties stablized with the increase in curing ages.