Alipujiang Jierula

Dr. Alipujiang Jierula

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AJAlipujiang Jierula
Alipujiang Jierula
CWCong Wu
Cong Wu
AKAbudusaimaiti Kali
Abudusaimaiti Kali
ZFZhixuan Fu
Zhixuan Fu
Acoustic emission (AE) source localization technology, since the early application to one-dimensional structures, has been extended to a wide range of applications to two-dimensional (2D) structures, including isotropic and anisotropic materials, which are currently the most widely studied and the most mature. With the development of AE source localization technology, more and more significant challenges have arisen for three-dimensional (3D) structures, which are mostly anisotropic and have complex propagation paths. This paper summarizes and discusses the AE source localization methods in different dimensions as well as their applications, including the main methods for 2D AE source localization, such as the triangulation method, beam forming, strain rosette technique, modal AE, artificial neural network, optimization and the time reversal technique, as well as state-of-the-art AE source localization methods in isotropic and anisotropic structures utilizing these methods. Recent advances in AE source localization in complex 3D structures are also reviewed.

7 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
AJAlipujiang Jierula
Alipujiang Jierula
HLHaodong Li
Haodong Li
YCYang Chen
Yang Chen
CWCong Wu
Cong Wu
潇吴潇 吴
潇 吴
涵尹涵林 尹
涵林 尹
In this paper, we study the influence of density and the water–cement (W/C) ratio on the slurry fluidity, compressive strength, and water absorption of foamed concrete (FC) and its mechanism of action, with the aim of proposing an optimal mix ratio for FC to reduce cement usage and carbon emissions in the construction industry and ensure the good overall performance of FC. In this experiment, two groups of experiments were designed using the control variable method. Fluidity and uniaxial compression tests showed that when the density was 600 kg/m3 and the W/C ratio was 0.6, the FC slurry had maximum fluidity, but its mechanical properties were poor and it collapsed easily. Conversely, by analyzing the uniaxial compressive strength/cement (UCS/C) ratio, it was observed that the mix ratio had a maximum cement utilization rate (W/C ratio) of 0.5 and a density of 1000 kg/m3. Nondestructive testing methods were used to measure the ultrasonic pulse velocity (UPV) and rebound value of the FC test block, and the strength and durability of FC were analyzed. The water absorption rate of the FC test block was tested, and the final analysis showed that the optimal mix ratio of FC in this test was W/C = 0.5, with a density of 1000 kg/m3.

8 August 2024 in Materials
Verified
Journal Article
Open access
PDF file
AJAlipujiang Jierula
Alipujiang Jierula
CWCong Wu
Cong Wu
ZFZhixuan Fu
Zhixuan Fu
HNHushitaer Niyazi
Hushitaer Niyazi
HLHaodong Li
Haodong Li
Recycled concrete is a new and environmentally friendly material for future construction. When applying recycled concrete to cold and severe regions, it is necessary to consider the freeze–thaw resistance of recycled concrete. Using an indoor freeze–thaw cycle test system, the rapid freezing method was used to conduct rapid freeze–thaw tests on recycled concrete specimens under set freeze–thaw cycle conditions. Relevant parameters (such as compressive strength, quality loss rate, rebound value) were tested on recycled concrete specimens that completed the set number of freeze–thaw cycles. The influence of various factors (freeze–thaw cycle number, replacement rate of recycled aggregates) on the compressive strength, quality loss rate, and rebound value of recycled concrete was analyzed. The results indicate that with the increase of freeze–thaw cycles and recycled aggregate content, the workability, rebound value, and compressive strength of the specimens decrease, and the quality loss rate increases. The changes in workability of concrete are sharp, with a slump difference of 21 mm between concrete with 100% recycled coarse aggregate and concrete using natural coarse aggregate. The rebound value of the specimen shows a decreasing trend overall, but the rebound value varies for different measuring points on the same specimen. The attenuation of compressive strength is significant. When fully using recycled aggregates to prepare concrete, the compressive strength after 30 freeze–thaw cycles decreases by 49.42% compared to the compressive strength after 0 freeze–thaw cycles. The overall quality loss rate shows a decreasing trend, but the quality loss is not severe.

2 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AJAlipujiang Jierula
Alipujiang Jierula
HLHaodong Li
Haodong Li
TOTae-Min Oh
Tae-Min Oh
XLXiaolong Li
Xiaolong Li
JWJin Wu
Jin Wu
YCYang Chen
Yang Chen
This study aims to enhance the performance of an innovative steel slag–ceramsite foam concrete (SSCFC) to advance sustainable green building materials. An eco-friendly composite construction material was developed by integrating industrial by-product steel slag (SS) with lightweight ceramsite. Employing a three-factor, three-level orthogonal experimental design at a fixed density of 800 kg/m3, 12 mix proportions (including a control group) were investigated with the variables of water-to-cement (W/C) ratio, steel slag replacement ratio, and ceramsite replacement ratio. The governing mechanisms of the W/C ratio, steel slag replacement level, and ceramsite replacement proportion on the SSCFC’s fluidity and compressive strength (CS) were elucidated. The synergistic application of range analysis and analysis of variance (ANOVA) quantified the significance of factors on target properties, and partial least squares regression (PLSR)-based prediction models were established. The test results indicated the following significance hierarchy: steel slag replacement > W/C ratio > ceramsite replacement for fluidity. In contrast, W/C ratio > ceramsite replacement > steel slag replacement governed the compressive strength. Verification showed R2 values exceeding 65% for both fluidity and CS predictions versus experimental data, confirming model reliability. Multi-criteria optimization yielded optimal compressive performance and suitable fluidity at a W/C ratio of 0.4, 10% steel slag replacement, and 25% ceramsite replacement.

26 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XZXiaojian Zhang
Xiaojian Zhang
SZShiyi Zhao
Shiyi Zhao
AJAlipujiang Jierula
Alipujiang Jierula
QLqing liu
qing liu
To investigate the influence of different connection configurations of viscous dampers on seismic mitigation performance, this study conducts a numerical simulation analysis of a 10-story inpatient building in Bazhou People’s Hospital, comparing the energy dissipation efficacy of viscous dampers under three connection types: diagonal bracing, chevron bracing, and wall-mounted connections. The results demonstrate that both chevron and wall-mounted configurations exhibit superior seismic mitigation performance compared to diagonal bracing. Specifically, chevron bracing is more suitable for mid- to high-rise structures, while wall-mounted connections achieve marginally better performance in low-rise buildings. However, the latter’s efficacy diminishes in mid- to high-rise structures due to the influence of wall self-weight. This study provides practical insights for optimizing the arrangement and application of viscous dampers in engineering projects.

18 January 2026 in Construction and Building Materials
Verified
Journal Article
Closed access
CWCong Wu
Cong Wu
AJAlipujiang Jierula
Alipujiang Jierula
Fujian TangFujian Tang
Fujian Tang
JWJin Wu
Jin Wu
TOTae-Min Oh
Tae-Min Oh