Xin Wang

Dr. Xin Wang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Xin WangXin Wang
Xin Wang
DLDekang Li
Dekang Li
QZQi Zhang
Qi Zhang
TLTian Li
Tian Li
ZCZhiyin Cao
Zhiyin Cao
FWFei Wang
Fei Wang
Oily fine particles are an important air pollutant in industrial environments. Workers exposed to oil mist for a long time face great health risks. Particle growth pretreatment is a technical principle to increase particle size and improve purification efficiency. Acoustic waves are commonly used to acheive particle growth, and a large number of acoustic wave agglomeration experiments have been carried out on non-oil fog. However, studies on oily particles are few. On the basis of previous studies on acoustic agglomeration of non-oily particles, this experiment designed a set of experimental equipment to compare the agglomeration effect of oily and non-oily particles. It was found that the agglomeration effect ratio of oily and non-oily particles to φ1oiliness/φ1non-oily particles was greater than 1. Therefore, the agglomeration effect of oily particles under stationary acoustic waves was more obvious. Results clearly show that oily particles have a higher agglomeration ability. In this study, a traditional ventilation and purification technology was expanded to include sound agglomeration technology into the pretreatment stage of purification and dust removal, thereby demonstrating feasibility of improved purification efficiency of an oily fine particle purification system, and laying a foundation for engineering applications.

FWFei Wang
Fei Wang
QMqinpeng meng
qinpeng meng
CLChengjie Lin
Chengjie Lin
Xin WangXin Wang
Xin Wang
WWWenbing Weng
Wenbing Weng
The widespread use of metal working fluids (MWFs) in machining processes leads to the production of a large number of harmful oil particles, which may pose serious health hazards to workers. The oil particle concentration has an inhomogeneous distribution in large spaces under displacement ventilation (DV) system, and the supply air volume required to maintain a low particle concentration under a DV system may be less than that needed under a mixing ventilation system. In this study, computational fluid dynamics (CFD) was used to study the particle concentration distribution rules and characteristics under various particle sizes in a large-space machine workshop with a DV system. Several distribution indices, such as the inhomogeneity factor and stratification height were utilized to analyze the inhomogeneous distribution of particle concentration; furthermore, sensitivity analyses were conducted for these indices. We found that the particle concentration shows a similar inhomogeneity factor distribution rule along the vertical direction under an air change rate of 2–6 in the DV system. The workspace inhomogeneity factor of particles smaller than 5 μm is less than 0.25, whereas that of 10-μm particles declines with an increase in air supply volume. Approximately double the supply air volume is required to keep the 10-μm particle concentration at the same level as particles smaller than 5 μm. The workspace inhomogeneity factor of small particles (5 μm) is more sensitive to the supply air volume than other parameters. The results of this study can be applied for the design and control of displacement ventilation systems in large-space machining workshops.

21 October 2023 in Building and Environment
Verified
Journal Article
Closed access
RZRuiyan Zhang
Ruiyan Zhang
ZLZiying Li
Ziying Li
Xin WangXin Wang
Xin Wang
FWFei Wang
Fei Wang
Lingjie ZengLingjie Zeng
Lingjie Zeng
ZLZhenhai Li
Zhenhai Li

18 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YLYilin Li
Yilin Li
YLYang Lu
Yang Lu
JSJie Sun
Jie Sun
TWTianhang Wang
Tianhang Wang
SZShiji Zong
Shiji Zong
Xin WangXin Wang
Xin Wang
With the increase in application of solar PV systems, it is of great significance to develop and investigate direct current (DC)-powered equipment in buildings with flexible operational strategies. A promising piece of building equipment integrated in PV-powered buildings, DC inverter heat pump systems often operate with strategies either focused on the power supply side or on the building demand side. In this regard, the aim of this study was to investigate the operational strategy of a DC inverter heat pump system for application in an office building with a PV power system. Firstly, the PV power fluctuation and demand-side load characteristics were analyzed. Then, a series of heat transfer and heat pump system models were developed. A reference building model was developed for simulating the performance of the system. A control logic of the DC inverter heat pump was proposed with a certain level of flexibility and capability considering both the characteristics of the PV power generation and the demand-side heating load. MATLAB/Simulink 2021 software was used for simulation. The simulation results show that the DC inverter heat pump is able to regulate its own power according to the change signal of the bus voltage such that the DC distribution network can achieve power balance and thus provide enough energy for a room. This study can provide a reference for developing flexible operational strategies for DC inverter heat pump systems. The proposed strategy can also help to improve the systems’ performance when they are applied in buildings with distributed PV systems.

1 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CLChao Li
Chao Li
HLHao Li
Hao Li
MZMinwei Zhang
Minwei Zhang
Xin WangXin Wang
Xin Wang
CHCui Huang
Cui Huang
Existing research of non-unidirectional cleanrooms generally suggests that lower-side return air outlets provide better control effect on indoor particle concentration. As a result, there has been relatively less focus on return air outlets. However, installing return air outlets oriented towards operators as particle emission sources can reduce the impact on process layout and improve space utilization, while also provide less impact from upper particle emission sources on the workbench area. To investigate the characteristics of return air outlet for operators (abbreviated asH), this study compared the particle concentration distribution, non—uniformity, and purification efficiency of return air oultetHand the traditional lower-side (abbreviated asL) return air outlets by experiments and CFD simulations. Based on the theory of mass conservation, the expression of required air supply volume under equivalent cleanroom conditions was derived. Under corresponding experimental and simulation conditions, the particle concentration differences range from 2.0% to 12.7% for return air outletHand from 12.4% to 33.2% for return air outletL, and these differences gradually decrease with the air exchange rate (ACH) increases. The results show that ACH = 20 is sufficient for cleanliness requirements with return air outletHwhen there is one person in the cleanroom, while a higher rate of ACH = 35 is needed when there are two persons. Although lower-side return air outlets have certain potential for reducing particle concentration in the cleanroom, increasing the air exchange rate remains the most effective method to control indoor particle concentration. Compared to the traditional lower-side return air outletL, the ranges of the non-uniformity coefficients for return air outletHandLare 0.50 to 0.67 and 0.45 to 0.53, respectively. The average non-uniformity coefficient differs by 11.9%, and there is not a significant difference in uniformity with more than 20 air changes per hour. The use of return air outletsHonly requires an additional 11% of air supply volume to achieve the same cleanliness, demonstrating its effectiveness in controlling particle concentration. It is suitable for cleanrooms with higher requirements for workbenches and for cleanrooms with restricted floor usage or requiring flexible layouts. The study also explores the impact of width of return air outlet oriented towards operators as particle emission sources, the results show that the larger-sized outlets facilitate the particle discharge and control the particle distribution inside the room.

1 February 2016 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
Xin WangXin Wang
Xin Wang
CHChen Huang
Chen Huang
ZZZhijun Zou
Zhijun Zou
Reasonable test, diagnosis, and analysis are meaningful for building energy efficiency retrofit and management. Energy consumption and greenhouse gas emission of a large-scale commercial building are described in this article. Basic information about energy consumption equipment is included in the investigation. Further diagnoses about the operational state of air-conditioning water systems, and ducted systems were implemented. Energy consumption decreased 200 kWh/m2 per year from 2007 to 2009 after energy-saving reconstruction in 2006. Next, a carbon audit was carried out; this comprised CO2 emission statistics associated with the energy use and categorization and structural analysis (categorization refers to energy categorization and structural analysis means the composition and its proportion relationship of all kinds of primary energy and secondary energy in energy production or consumption). Greenhouse gas emissions could be less than 150 kg/m2 per year from 2007 to 2009. An analysis of the correlation between CO2 emissions, building gross domestic product, and energy efficiency is also presented. This article makes an analysis on the energy utilization and energy-saving reconstruction of a public commercial building in Shanghai and then makes an analysis of carbon audit about greenhouse gas emissions related to energy utilization (it analyzes the status of building’s energy utilization and greenhouse gas emissions), to have a more comprehensive understanding on the internal relationship between energy consumption and its greenhouse gas emissions and provide researchful reference data for the development with reduction strategies of greenhouse gas emission in future building.