Gábor Orbán

Dr. Gábor Orbán

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
MBMárton Boga
Márton Boga
FSFerenc Imre Suhai
Ferenc Imre Suhai
GOGábor Orbán
Gábor Orbán
ZSZoltán Salló
Zoltán Salló
VNVivien Kaludia Nagy
Vivien Kaludia Nagy
NSNándor Szegedi
Nándor Szegedi
Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter–tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.

1 February 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
NSNándor Szegedi
Nándor Szegedi
ZSZoltán Salló
Zoltán Salló
VNVivien Kaludia Nagy
Vivien Kaludia Nagy
IOIstván Osztheimer
István Osztheimer
IHIstvan Hizoh
Istvan Hizoh
LGLászló Gellér
László Gellér
BACKGROUND: High-power short-duration ablation has shown impressive efficacy and safety for pulmonary vein isolation (PVI); however, initial efficacy results with very high power short-duration ablation were discouraging. This study compared the long-term durability of PVI performed with a 90- versus 50-W power setting. METHODS: Patients were randomized 1:1 to undergo PVI with the QDOT catheter using a power setting of 90 or 50 W. Three months after the index procedure, patients underwent a repeat electrophysiology study to identify pulmonary vein reconnections. Patients were followed for 12 months to detect AF recurrences. RESULTS: We included 46 patients (mean age, 64 years; women, 48%). Procedure (76 versus 84 minutes; P =0.02), left atrial dwell (63 versus 71 minutes; P =0.01), and radiofrequency (303 versus 1040 seconds; P <0.0001) times were shorter with 90- versus 50-W procedures, while the number of radiofrequency applications was higher with 90 versus 50 W (77 versus 67; P =0.01). There was no difference in first-pass isolation (83% versus 82%; P =1.0) or acute reconnection (4% versus 14%; P =0.3) rates between 90 and 50 W. Forty patients underwent a repeat electrophysiology study. Durable PVI on a per PV basis was present in 72/78 (92%) versus 68/77 (88%) PVs in the 90- and 50-W energy setting groups, respectively; effect size: 72/78−68/77=0.040, lower 95% CI=−0.051 (noninferiority limit=−0.1, ie, noninferiority is met). No complications occurred. There was no difference in 12-month atrial fibrillation-free survival between the 90- and 50-W groups ( P =0.2). CONCLUSIONS: Similarly high rates of durable PVI and arrhythmia-free survival were achieved with 90 and 50 W. Procedure, left atrial dwell, and radiofrequency times were shorter with 90 W compared with 50 W. The sample size is too small to conclude the safety and long-term efficacy of the high and very high-power short-duration PVI; further studies are needed to address this topic. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05459831.

7 July 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
ZSZoltán Salló
Zoltán Salló
PPPéter Perge
Péter Perge
BBBernadett Balogi
Bernadett Balogi
GOGábor Orbán
Gábor Orbán
KPKatalin Piros
Katalin Piros
NSNándor Szegedi
Nándor Szegedi
Introduction: High-power short-duration (HPSD) radiofrequency ablation has been proposed to produce rapid and effective lesions for pulmonary vein isolation (PVI). We aimed to evaluate the procedural characteristics and the first-pass isolation (FPI) rate of HPSD and very high-power short-duration (vHPSD) ablation compared to the low-power long-duration (LPLD) ablation technique.Methods: One hundred fifty-six patients with atrial fibrillation (AF) were enrolled and assigned to LPLD, HPSD, or vHPSD PVI. The energy setting was 30, 50, and 90 W in the LPLD, HPSD, and vHPSD groups, respectively. In the vHPSD group, 90 W/4 s energy delivery was used in the QMODE+ setting. In the other groups, ablation index-guided applications were delivered with 30 W (LPLD) or 50 W (HPSD).Results: Bilateral PVI was achieved in all cases. Compared to the LPLD group, the HPSD and vHPSD groups had shorter procedure time [85 (75–101) min, 79 (65–91) min, and 70 (53–83) min], left atrial dwelling time [61 (55–70) min, 53 (41–56) min, and 45 (34–52) min], total RF time [1,567 (1,366–1,761) s, 1,398 (1,021–1,711) s, and 336 (247–386) s], but higher bilateral FPI rate (57, 78, and 80%) (all p-values < 0.01). The use of HPSD (OR = 2.72, 95% CI 1.15–6.44, p = 0.023) and vHPSD (OR = 2.90, 95% CI 1.24–6.44, p = 0.014) ablation techniques were associated with a higher probability of bilateral FPI. The 9-month AF-recurrence rate was lower in case of HPSD and vHPSD compared to LPLD ablation (10, 8, and 36%, p = 0.0001). Moreover, the presence of FPI was associated with a lower AF-recurrence rate at 9-month (OR = 0.09, 95% CI 0.04–0.24, p = 0.0001).Conclusion: Our prospective, observational cohort study showed that both HPSD and vHPSD RF ablation shortens procedure and RF time and results in a higher rate of FPI compared to LPLD ablation. Moreover, the use of HPSD and vHPSD ablation increased the acute and mid-term success rate. No safety concerns were raised for HPSD or vHPSD ablation in our study.

15 February 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
NSNándor Szegedi
Nándor Szegedi
JSJudit Simon
Judit Simon
BSBalint Szilveszter
Balint Szilveszter
ZSZoltán Salló
Zoltán Salló
SHSzilvia Szív- és Érgyógyászati Herczeg
Szilvia Szív- és Érgyógyászati Herczeg
LGLászló Gellér
László Gellér
Introduction: The role of the spatial relationship between the left superior pulmonary vein (LSPV) and left atrial appendage (LAA) is unknown. We sought to evaluate whether an abutting LAA and LSPV play a role in AF recurrence after catheter ablation for paroxysmal AF.Methods: Consecutive patients, who underwent initial point-by-point radiofrequency catheter ablation for paroxysmal AF at the Heart and Vascular Center of Semmelweis University, Budapest, Hungary, between January of 2014 and December of 2017, were enrolled in the study. All patients underwent pre-procedural cardiac CT to assess left atrial (LA) and pulmonary vein (PV) anatomy. Abutting LAA-LSPV was defined as cases when the minimum distance between the LSPV and LAA was less than 2 mm.Results: We included 428 patients (60.7 ± 10.8 years, 35.5% female) in the analysis. AF recurrence rate was 33.4%, with a median recurrence-free time of 21.2 (8.8–43.0) months. In the univariable analysis, female sex (HR = 1.45; 95%CI = 1.04–2.01; p = 0.028), LAA flow velocity (HR = 1.01; 95%CI = 1.00–1.02; p = 0.022), LAA orifice area (HR = 1.00; 95%CI = 1.00–1.00; p = 0.028) and abutting LAA-LSPV (HR = 1.53; 95%CI = 1.09–2.14; p = 0.013) were associated with AF recurrence. In the multivariable analysis, abutting LAA-LSPV (adjusted HR = 1.55; 95%CI = 1.04–2.31; p = 0.030) was the only independent predictor of AF recurrence.Conclusion: Abutting LAA-LSPV predisposes patients to have a higher chance for arrhythmia recurrence after catheter ablation for paroxysmal AF.

9 February 2022 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
MBMelinda Boussoussou
Melinda Boussoussou
BSBálint Szilveszter
Bálint Szilveszter
BVBorbála Vattay
Borbála Vattay
MKMárton Kolossváry
Márton Kolossváry
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
NSNándor Szegedi
Nándor Szegedi
Nowadays, a novel contact-force guided ablation technique is used for enclosing pulmonary veins in patients with atrial fibrillation (AF). We sought to determine whether left atrial (LA) wall thickness (LAWT) and pulmonary vein (PV) dimensions, as assessed by cardiac CT, could influence the success rate of first-pass pulmonary vein isolation (PVI). In a single-center, prospective study, we enrolled consecutive patients with symptomatic, drug-refractory AF who underwent initial radiofrequency catheter ablation using a modified CLOSE protocol. Pre-procedural CT was performed in all cases. Additionally, the diameter and area of the PV orifices were obtained. A total of 1034 LAWT measurements and 376 PV area measurements were performed in 94 patients (mean CHA2DS2-VASc score 2.1 ± 1.5, mean age 62.4 ± 12.6 years, 39.5% female, 38.3% persistent AF). Mean procedure time was 81.2 ± 19.3 min. Complete isolation of all PVs was achieved in 100% of patients. First-pass isolation rate was 76% and 71% for the right-sided PVs and the left-sided PVs, respectively. No difference was found regarding comorbidities and imaging parameters between those with and without first-pass isolation. LAWT (mean of 11 regions or separately) had no effect on the acute procedural outcome on logistic regression analysis (all p ≥ 0.05). Out of all assessed parameters, only RSPV diameter was associated with a higher rate of successful right-sided first pass isolation (OR 1.01, p = 0.04). Left atrial wall thickness does not have an influence on the acute procedural success of PVI using ablation index and a standardized ablation protocol. RSPV diameter could influence the probability of right sided first-pass isolation.

13 July 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
GOGábor Orbán
Gábor Orbán
ZSZoltán Salló
Zoltán Salló
PPPéter Perge
Péter Perge
PÁPál Ábrahám
Pál Ábrahám
KPKatalin Piros
Katalin Piros
NSNándor Szegedi
Nándor Szegedi
Introduction: Pulmonary vein isolation is the cornerstone of rhythm-control therapy for atrial fibrillation (AF). The very high-power, short-duration (vHPSD) radiofrequency (RF) ablation is a novel technology that favors resistive heating while decreasing the role of conductive heating. Our study aimed to evaluate the correlations between contact force (CF), power, impedance drop (ID), and temperature; and to assess their role in lesion formation with the vHPSD technique.Methods: Consecutive patients who underwent initial point-by-point RF catheter ablation for AF were enrolled in the study. The vHPSD ablation was performed applying 90 W for 4 s with an 8 ml/min irrigation rate.Results: Data from 85 patients [median age 65 (59–71) years, 34% female] were collected. The median procedure time, left atrial dwelling time, and fluoroscopy time were 70 (60–90) min, 49 (42–58) min, and 7 (5–11) min, respectively. The median RF time was 312 (237-365) sec. No steam pop nor major complications occurred. A total of 6,551 vHPSD RF points were analyzed. The median of CF, maximum temperature, and ID were 14 (10–21) g, 47.6 (45.1–50.4) °C, and 8 (6–10) Ohms, respectively. CF correlated significantly with the maximum temperature (p < 0.0001). A CF of 5 g and above was associated with a significantly higher temperature compared to those lesions with a CF below 5 grams (p < 0.0001). Bilateral first-pass isolation rate was 84%. The 6-month AF-recurrence rate was 7%.Conclusion: The maximum temperature and CF significantly correlate with each other during vHPSD applications. A CF ≥ 5 g leads to better tissue heating and thus might be more likely to result in good lesion formation, although this clinical study was unable to assess actual lesion sizes.