Zoltán Salló

Zoltán Salló

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
MBMárton Boga
Márton Boga
FSFerenc Imre Suhai
Ferenc Imre Suhai
GOGábor Orbán
Gábor Orbán
ZSZoltán Salló
Zoltán Salló
VNVivien Kaludia Nagy
Vivien Kaludia Nagy
NSNándor Szegedi
Nándor Szegedi
Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter–tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.

1 February 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
NSNándor Szegedi
Nándor Szegedi
ZSZoltán Salló
Zoltán Salló
VNVivien Kaludia Nagy
Vivien Kaludia Nagy
IOIstván Osztheimer
István Osztheimer
IHIstvan Hizoh
Istvan Hizoh
LGLászló Gellér
László Gellér
BACKGROUND: High-power short-duration ablation has shown impressive efficacy and safety for pulmonary vein isolation (PVI); however, initial efficacy results with very high power short-duration ablation were discouraging. This study compared the long-term durability of PVI performed with a 90- versus 50-W power setting. METHODS: Patients were randomized 1:1 to undergo PVI with the QDOT catheter using a power setting of 90 or 50 W. Three months after the index procedure, patients underwent a repeat electrophysiology study to identify pulmonary vein reconnections. Patients were followed for 12 months to detect AF recurrences. RESULTS: We included 46 patients (mean age, 64 years; women, 48%). Procedure (76 versus 84 minutes; P =0.02), left atrial dwell (63 versus 71 minutes; P =0.01), and radiofrequency (303 versus 1040 seconds; P <0.0001) times were shorter with 90- versus 50-W procedures, while the number of radiofrequency applications was higher with 90 versus 50 W (77 versus 67; P =0.01). There was no difference in first-pass isolation (83% versus 82%; P =1.0) or acute reconnection (4% versus 14%; P =0.3) rates between 90 and 50 W. Forty patients underwent a repeat electrophysiology study. Durable PVI on a per PV basis was present in 72/78 (92%) versus 68/77 (88%) PVs in the 90- and 50-W energy setting groups, respectively; effect size: 72/78−68/77=0.040, lower 95% CI=−0.051 (noninferiority limit=−0.1, ie, noninferiority is met). No complications occurred. There was no difference in 12-month atrial fibrillation-free survival between the 90- and 50-W groups ( P =0.2). CONCLUSIONS: Similarly high rates of durable PVI and arrhythmia-free survival were achieved with 90 and 50 W. Procedure, left atrial dwell, and radiofrequency times were shorter with 90 W compared with 50 W. The sample size is too small to conclude the safety and long-term efficacy of the high and very high-power short-duration PVI; further studies are needed to address this topic. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05459831.

16 September 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NSNándor Szegedi
Nándor Szegedi
ZSZoltán Salló
Zoltán Salló
PPPéter Perge
Péter Perge
KPKatalin Piros
Katalin Piros
VNVivien Klaudia Nagy
Vivien Klaudia Nagy
LGLászló Gellér
László Gellér
Introduction: Our pilot study aimed to evaluate the role of local impedance drop in lesion formation during pulmonary vein isolation with a novel contact force sensing ablation catheter that records local impedance as well and to find a local impedance cut-off value that predicts successful lesion formation. Materials and methods: After completing point-by-point radiofrequency pulmonary vein isolation, the success of the applications was evaluated by pacing along the ablation line at 10 mA, 2 ms pulse width. Lesions were considered successful if loss of local capture was achieved. Results: Out of 645 applications, 561 were successful and 84 were unsuccessful. Compared to the unsuccessful ablation points, the successful applications were shorter (p = 0.0429) and had a larger local impedance drop (p<0.0001). There was no difference between successful and unsuccessful applications in terms of mean contact force (p = 0.8571), force-time integral (p = 0.0699) and contact force range (p = 0.0519). The optimal cut-point for the local impedance drop indicating successful lesion formation was 21.80 Ohms on the anterior wall [AUC = 0.80 (0.75–0.86), p<0.0001], and 18.30 Ohms on the posterior wall [AUC = 0.77 (0.72–0.83), p<0.0001]. A local impedance drop larger than 21.80 Ohms on the anterior wall and 18.30 Ohms on the posterior wall was associated with an increased probability of effective lesion creation [OR = 11.21, 95%CI 4.22–29.81, p<0.0001; and OR = 7.91, 95%CI 3.77–16.57, p<0.0001, respectively]. Conclusion: The measurement of the local impedance may predict optimal lesion formation. A local impedance drop > 21.80 Ohms on the anterior wall and > 18.30 Ohms on the posterior wall significantly increases the probability of creating a successful lesion.

7 July 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
ZSZoltán Salló
Zoltán Salló
PPPéter Perge
Péter Perge
BBBernadett Balogi
Bernadett Balogi
GOGábor Orbán
Gábor Orbán
KPKatalin Piros
Katalin Piros
NSNándor Szegedi
Nándor Szegedi
Introduction: High-power short-duration (HPSD) radiofrequency ablation has been proposed to produce rapid and effective lesions for pulmonary vein isolation (PVI). We aimed to evaluate the procedural characteristics and the first-pass isolation (FPI) rate of HPSD and very high-power short-duration (vHPSD) ablation compared to the low-power long-duration (LPLD) ablation technique.Methods: One hundred fifty-six patients with atrial fibrillation (AF) were enrolled and assigned to LPLD, HPSD, or vHPSD PVI. The energy setting was 30, 50, and 90 W in the LPLD, HPSD, and vHPSD groups, respectively. In the vHPSD group, 90 W/4 s energy delivery was used in the QMODE+ setting. In the other groups, ablation index-guided applications were delivered with 30 W (LPLD) or 50 W (HPSD).Results: Bilateral PVI was achieved in all cases. Compared to the LPLD group, the HPSD and vHPSD groups had shorter procedure time [85 (75–101) min, 79 (65–91) min, and 70 (53–83) min], left atrial dwelling time [61 (55–70) min, 53 (41–56) min, and 45 (34–52) min], total RF time [1,567 (1,366–1,761) s, 1,398 (1,021–1,711) s, and 336 (247–386) s], but higher bilateral FPI rate (57, 78, and 80%) (all p-values < 0.01). The use of HPSD (OR = 2.72, 95% CI 1.15–6.44, p = 0.023) and vHPSD (OR = 2.90, 95% CI 1.24–6.44, p = 0.014) ablation techniques were associated with a higher probability of bilateral FPI. The 9-month AF-recurrence rate was lower in case of HPSD and vHPSD compared to LPLD ablation (10, 8, and 36%, p = 0.0001). Moreover, the presence of FPI was associated with a lower AF-recurrence rate at 9-month (OR = 0.09, 95% CI 0.04–0.24, p = 0.0001).Conclusion: Our prospective, observational cohort study showed that both HPSD and vHPSD RF ablation shortens procedure and RF time and results in a higher rate of FPI compared to LPLD ablation. Moreover, the use of HPSD and vHPSD ablation increased the acute and mid-term success rate. No safety concerns were raised for HPSD or vHPSD ablation in our study.

15 February 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
NSNándor Szegedi
Nándor Szegedi
JSJudit Simon
Judit Simon
BSBalint Szilveszter
Balint Szilveszter
ZSZoltán Salló
Zoltán Salló
SHSzilvia Szív- és Érgyógyászati Herczeg
Szilvia Szív- és Érgyógyászati Herczeg
LGLászló Gellér
László Gellér
Introduction: The role of the spatial relationship between the left superior pulmonary vein (LSPV) and left atrial appendage (LAA) is unknown. We sought to evaluate whether an abutting LAA and LSPV play a role in AF recurrence after catheter ablation for paroxysmal AF.Methods: Consecutive patients, who underwent initial point-by-point radiofrequency catheter ablation for paroxysmal AF at the Heart and Vascular Center of Semmelweis University, Budapest, Hungary, between January of 2014 and December of 2017, were enrolled in the study. All patients underwent pre-procedural cardiac CT to assess left atrial (LA) and pulmonary vein (PV) anatomy. Abutting LAA-LSPV was defined as cases when the minimum distance between the LSPV and LAA was less than 2 mm.Results: We included 428 patients (60.7 ± 10.8 years, 35.5% female) in the analysis. AF recurrence rate was 33.4%, with a median recurrence-free time of 21.2 (8.8–43.0) months. In the univariable analysis, female sex (HR = 1.45; 95%CI = 1.04–2.01; p = 0.028), LAA flow velocity (HR = 1.01; 95%CI = 1.00–1.02; p = 0.022), LAA orifice area (HR = 1.00; 95%CI = 1.00–1.00; p = 0.028) and abutting LAA-LSPV (HR = 1.53; 95%CI = 1.09–2.14; p = 0.013) were associated with AF recurrence. In the multivariable analysis, abutting LAA-LSPV (adjusted HR = 1.55; 95%CI = 1.04–2.31; p = 0.030) was the only independent predictor of AF recurrence.Conclusion: Abutting LAA-LSPV predisposes patients to have a higher chance for arrhythmia recurrence after catheter ablation for paroxysmal AF.

27 May 2024 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
PTPatrik Tóth
Patrik Tóth
BABence Arnóth
Bence Arnóth
FKFerenc Komlosi
Ferenc Komlosi
NSNándor Szegedi
Nándor Szegedi
ZSZoltán Salló
Zoltán Salló
MGmembers of the SU EP Study Group
members of the SU EP Study Group
Introduction: According to current guidelines, pulmonary vein isolation as first‐line therapy should be considered for patients with atrial fibrillation (AF), however, optimal timing of the procedure is still unknown in patients with heart failure (HF). We aimed to evaluate the effect of early catheter ablation (CA) in patients with HF and left ventricular ejection fraction (LVEF) below 50%.Methods: We analyzed data from a structured registry comprising 227 patients with paroxysmal or persistent AF and HF with LVEF < 50% who underwent radiofrequency CA between 2015 and 2022. Early CA was defined as a procedure performed within 12 months of AF diagnosis. The median follow‐up duration was 1748 (1176.3–2353.5) days, with a minimum follow‐up of 365 days. Our endpoints were AF recurrence after a 3‐months blanking period and all‐cause mortality.Results: Among the 227 patients with a median age of 64.3 years, 97 (42.7%) experienced AF recurrence and 55 (24.2%) died during the follow‐up period. The median LVEF was 40% for early CA and 38% for delayed CA (p = .053). Early CA significantly reduced AF recurrence (HR = 0.25 [0.15–0.42], p < .001), however, the timing of procedure did not affect all‐cause mortality (p = .16). These findings were consistent regardless of AF subtype or the burden of comorbidities, as assessed by the CHA2DS2‐VASc score.Conclusion: The timing of CA of AF appears to be an important factor in patients with HF. Early CA reduced AF recurrence, although it does not impact all‐cause mortality. We found similar results regardless of AF subtype or burden of comorbidities.