Silicon carbide (SiC) is a wide band-gap semiconductor material with many excellent properties, showing great potential in fusion neutron detection. The radiation resistance of 4H-SiC Schottky diode detectors was studied experimentally by carefully analyzing the detectors’ properties before and after deuterium-tritium fusion neutron irradiation with the total fluence of 1.31 × 1014 n/cm2 and 7.29 × 1014 n/cm2 at room temperature. Significant degradation has been observed after neutron irradiation: reverse current increased greatly, over three to thirty fold; Schottky junction was broken down; significant lattice damage was observed at low temperature photoluminescence measurements; the peaks of alpha particle response spectra shifted to lower channels and became wider; the charge collection efficiency (CCE) decreased by about 7.0% and 22.5% at 300 V with neutron irradiation fluence of 1.31 × 1014 n/cm2 and 7.29 × 1014 n/cm2, respectively. Although the degradation exists, the SiC detectors successfully survive intense neutron radiation and show better radiation resistance than silicon detectors.
Silicon carbide (SiC) detectors of an Ni/4H-SiC Schottky diode structure and with sensitive areas of 1–4 cm2 were fabricated using high-quality lightly doped epitaxial 4H-SiC material, and were tested in the detection of alpha particles and pulsed X-rays/UV-light. A linear energy response to alpha particles ranging from 5.157 to 5.805 MeV was obtained. The detectors were proved to have a low dark current, a good energy resolution, and a high neutron/gamma discrimination for pulsed radiation, showing the advantages in charged particle detection and neutron detection in high-temperature and high-radiation environments.
1 December 2017 in Review of Scientific Instruments
Silicon carbide radiation detectors are attractive in the measurement of the total numbers of pulsed fast neutrons emitted from nuclear fusion and fission devices because of high neutron-gamma discrimination and good radiation resistance. A fast-neutron detection system was developed based on a large-area 4H–SiC Schottky diode detector and a 235U fission target. Excellent pulse-height spectra of fission fragments induced by mono-energy deuterium-tritium (D-T) fusion neutrons and continuous energy fission neutrons were obtained. The detector is proven to be a good candidate for pulsed fast neutron detection in a complex radiation field.
30 March 2021 in IEEE Transactions on Nuclear Science
Silicon carbide (SiC) detectors have great potential in nuclear fusion diagnosis and intense irradiation field measurement due to their outstanding irradiation resistance, high charge collection efficiency (CCE), and fast pulse response time. However, the irradiation resistance and the performance degradation of SiC detectors as a result of He ion irradiation remains unclear. In this article, SiC detectors based on 4H-type material with the p-i-n junction structure were prepared, and their I-V characteristics, α-particle spectra, and linearity of energy response were evaluated before and after He ion irradiation at fluences ranging from 1×10 12 to 3 ×10 15 cm -2 . The preirradiated SiC detector exhibited low dark current (<; 1 nA), high CCE (98.5%), and good energy resolution (0.87%). At an He ion irradiation fluence of 1 ×10 12 cm -2 , detector performance degradation was negligible, with no increase of dark current, CCE decreased to 85%, and a 2.2% degradation of energy resolution. At a fluence of 3 ×10 15 cm -2 , CCE decreased to 19.3%, with an 8.57% degradation in energy resolution, but the dark current was still lower than 2 nA, with good spectra measurement capabilities and high linearity of energy response. These results indicate that the He ion irradiation resistance of 4H-SiC detectors is 10 4 times greater than silicon (Si) detectors.