In this paper, commercially 1200 V asymmetric and double trench silicon carbide (SiC) metal-oxide-semiconductor-field-effect transistors (MOSFETs) from two manufacturers are investigated by experiment and finite-element simulation under single-pulse unclamped inductive switching (UIS) stress. The variation in avalanche time with MOSFET avalanche energy and temperatures dependence of critical avalanche energy and maximum power dissipation are evaluated. It is found that the two failure mechanisms are identified, i.e. thermal runaway and gate oxide rupture. For asymmetric trench SiC MOSFETs, the failure mode are all thermal runaway at various temperatures. However, the failure mode of double trench SiC MOSFETs is thermal runaway or gate oxide rupture, which indicates an instable avalanche robustness under UIS stress. The variations of DC parameters are recorded to evaluate external features of device failure. Furthermore, finite-element simulation is used to reveal the electro-thermal stress inside the device during avalanche. Finally, failed devices are decapsulated to verify the location of failure point from the perspective of the semiconductor die.
Silicon carbide (SiC) detectors of an Ni/4H-SiC Schottky diode structure and with sensitive areas of 1–4 cm2 were fabricated using high-quality lightly doped epitaxial 4H-SiC material, and were tested in the detection of alpha particles and pulsed X-rays/UV-light. A linear energy response to alpha particles ranging from 5.157 to 5.805 MeV was obtained. The detectors were proved to have a low dark current, a good energy resolution, and a high neutron/gamma discrimination for pulsed radiation, showing the advantages in charged particle detection and neutron detection in high-temperature and high-radiation environments.
18 April 2025 in IEEE Transactions on Nuclear Science
This study investigated the impact of latent damage induced by heavy ions on the gate reliability of 1200 V SiC MOSFETs. Irradiation was conducted using Kr and Ta ions, with linear energy transfer (LET) of 38.85 MeV·cm²/mg and 86.03 MeV·cm²/mg, respectively. Devices exhibiting latent damage underwent a 1000-hour assessment at a gate voltage of 20 V. The findings revealed a significant increase in gate leakage current after the assessment, which is presumed to be caused by trap-assisted tunneling effects. Furthermore, latent damage resulted in a reduction of gate breakdown voltage by approximately 50%. The research also indicated that latent damage did not significantly affect the threshold voltage and transfer characteristics of the devices, suggesting that they retained a degree of gate control capability. Two potential explanations are proposed, providing new insights into the long-term reliability evaluation of SiC MOSFETs post-irradiation.
26 September 2024 in IEEE Transactions on Device and Materials Reliability
A SiC trench junction barrier Schottky diode with multiple P-shield layers and an embedded N+ region (MPNT-JBS) is proposed and investigated for enhancing single-event burnout (SEB) tolerance. The Schottky contact at the sidewall of the trench and the embedded N+ region in MPNT-JBS accelerate the extraction and recombination of holes. The mitigated accumulation of holes contributes to the reduction of the strong electric field near the metal/SiC interface, thus favoring a decrease in the high temperature. Under 50% of the rated voltage (VCathode = 600 V), the maximum temperature near the metal/SiC interface in MPNT-JBS decreases by 78% and 71% compared to SiC JBS diode with multilayer N-buffer (MB-JBS), corresponding to the instances when heavy ions with a linear energy transfer (LET) value of 0.53 pC/lm strike the middle of the Schottky contact and the P+ region, respectively. In addition, the multilayer P-shield of MPNT-JBS suppresses the peak temperature near the PN junction by enlarging the energy dissipation area and lowering the transient heat power near the PN junction. Compared to MB-JBS, the maximum temperature near the PN junction in MPNT-JBS decreases from 1890 K to 1454 K when heavy ions strike the middle of the P+ region (VCathode = 600 V). These results indicate that MPNT-JBS provides potential for enhancing SEB tolerance.
A two-terminal npn device based on 4H-SiC has been employed as a radiation detector for the first time. This device was designed as a vertical npn structure with a sensitive area of up to 1 cm2, and the thickness of the sensitive layer was about $30~\mu $ m. The detector exhibited a low dark current of $\sim ~0.12$ nA $\cdot $ cm $^{-{2}}$ with a fully depleted sensitive region at 200 V. The sensitivity of unit area of the detector achieved $36.67~\mu $ C $\cdot $ Gy $^{-{1}} \cdot $ cm $^{-{2}}$ ( $28.09~\mu $ A @ 0.766 Gy/s) to X-ray illumination (generated by bremsstrahlung with a tungsten target with tube voltage 30 kV) at 200 V, which was attributed to the amplification mechanism of the npn structure. Compared with the response characteristics of a SiC-PiN detector with the same sensitive volume, the gain of the two-terminal SiC npn detector was estimated to be 11.46 at 200 V. Specifically, the internal gain of the detector increased with the X-ray dose rate, where the X-ray photocurrent worked as the base current in the BJT devices. The internal gain also increased with the bias voltage due to the Early effect. Moreover, the two-terminal SiC npn detectors had a good switching response to X-rays and showed great potential in the applications of radiation detection.
In this letter, the gate oxide degradation of SiC MOSFETs induced by dynamic gate stress under total ionizing dose irradiation is investigated to accurately evaluate the impact of the gate oxide reliability on the real device operating conditions. The threshold voltage (Vth) drift of SiC MOSFETs under dynamic gate voltage (Vgs) is only 0.21 V when the irradiation dose reaches 1 Mrad, whereas negative Vth drifts of 1.80 V and 0.68 V are observed under constant Vgs of +15 V and -5 V, respectively. This indicates that a conventional constant gate bias test will overestimate the instability of the Vth during irradiation. Meanwhile, it is also found that the oxide breakdown time at the electrical field of 9.5 MV/cm is decreased from 5280 s (Vgs = +15 V), 4400 s (Vgs = -5 V) to 430 s (dynamic gate bias) after the irradiation dose of 1 Mrad. The poor reliability of gate oxide and the relatively weak degradation of electrical properties after irradiation is mainly due to more electrons and holes trapped by oxide traps when a dynamic gate bias is applied. Based on the TDDB defect percolation model, widely distributed oxide charges can form potential conductive paths that accelerate defect percolation and gate oxide breakdown under high electric fields.