The evaluation of the efficacy of incorporation of quercetin in nanoparticles is crucial, both for the development and quality control of pharmaceutical formulations. The validation of analytical methods for the precise quantification of quercetin is useful for the evaluation of various potential quercetin delivery systems and quercetin pharmacokinetics. This work aimed to validate a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for quercetin detection and quantification in nanoparticles. Different mobile phase conditions and detection wavelengths (254 and 368 nm) were tested, and the major validation parameters were assessed (precision, accuracy, linearity, sensitivity, stability, and selectivity). The best peak resolution was obtained when quercetin was analyzed at 368 nm with a mobile phase of 1.5% acetic acid and a water/acetonitrile/methanol ratio of 55:40:5. Under these conditions, quercetin also eluted rapidly (retention time of 3.6 min). The method proved to be linear (R2 > 0.995), specific, and repeatable (variation coefficient between 2.4% and 6.7%) and presented intermediate precision (variation coefficient between 7.2% and 9.4%). The accuracy of the analysis ranged between 88.6% and 110.7%, and detection and quantification limits were 0.046 and 0.14 µg/mL, respectively. Quercetin solutions were more stable when stored at 4 °C than at room temperature or −20 °C. This validated method satisfied more parameters of bias assessment than most recent methods for quercetin determination and presented itself as more sensitive and efficient than general spectrophotometric methods. The method was successfully used for the analysis of quercetin incorporation in nanoparticles and will be evaluated in the future for its adequacy for the determination of quercetin in more complex matrices.
Major depressive disorder is a widespread condition with antidepressants as the main pharmacological treatment. However, some patients experience concerning adverse reactions or have an inadequate response to treatment. Analytical chromatographic techniques, among other techniques, are valuable tools for investigating medication complications, including those associated with antidepressants. Nevertheless, there is a growing need to address the limitations associated with these techniques. In recent years, electrochemical (bio)sensors have garnered significant attention due to their lower cost, portability, and precision. Electrochemical (bio)sensors can be used for various applications related to depression, such as monitoring the levels of antidepressants in biological and in environmental samples. They can provide accurate and rapid results, which could facilitate personalized treatment and improve patient outcomes. This state-of-the-art literature review aims to explore the latest advancements in the electrochemical detection of antidepressants. The review focuses on two types of electrochemical sensors: Chemically modified sensors and enzyme-based biosensors. The referred papers are carefully categorized according to their respective sensor type. The review examines the differences between the two sensing methods, highlights their unique features and limitations, and provides an in-depth analysis of each sensor.
25 July 2023 in Journal of Oncology Pharmacy Practice
Pharmacy professionals that manipulate cytotoxic drugs need to undergo educational programs, adopt the most convenient practices, and use appropriate equipment to avoid, as far as possible, occupational exposure to cytotoxic drugs. The main goal of this work is to characterize the education, technical practices, and attitudes towards cytotoxic drugs, of Portuguese pharmacy technicians. A questionnaire comprising eleven questions deemed pertinent was elaborated and subsequently validated by a pilot test. The anonymous, web-based survey was conducted between December 2022 and January 2023, by graduated pharmacy technicians that had manipulated cytotoxic drugs between 2017 and 2022. A total of 77 pharmacy technicians responded to the survey. Although sixty-six pharmacy technicians (86%) had been trained before beginning to manipulate cytotoxic drugs, the promotion of regular post-admission training by the institutions is sparse – only assumed by 53% of the pharmacy technicians ( n = 41). All participants reported using gloves and gown during manipulation and the use of double gloves was common (99%; n = 76). Compliances with the recommended limit time for uninterrupted manipulation activity (82%; n = 63) and systematic double-checking (86%; n = 66) were high, but the regular use of sterile gauze around syringe connection sites 58% ( n = 45), was less frequent. None of the surveyed pharmacy technicians used closed-system transfer devices (CSTD) and 41 (53%) of those who used spikes did not thoughtfully use these devices. The implementation of regular training programs in manipulating cytotoxic drugs should be fostered, to promote the more judicious use of engineering controls and transversal adoption of the safest technical practices.
Quercetin (QUE) is the most widely used flavonoid for therapeutic purposes. To improve the available knowledge about the properties of some natural products, determining the amount of QUE is crucial. The main objective of this systematic review is to identify the analytical methods validated for detecting and quantifying QUE in different matrices and characterize their sensitivity. A search was conducted until 30 June 2023 in the PubMed database for experimental studies that addressed the validation of chromatographic analytical methods to detect and quantify QUE from consumable natural products. Only studies published between 2018 and 2022, written in English, were included. The risk of bias was assessed by emphasizing methods of comparison according to previously published studies. Descriptive statistics were used to depict the obtained results. The studies were analyzed based on the type of QUE source, chromatographic method, and validation parameters. A total of 17 studies were included in this review. Plants were the most commonly analyzed source of QUE. Among the detection methods, spectrophotometry proved to be the most widely used, surpassing mass spectrometry (MS). After analyzing the bias, all the included studies mentioned/presented, totally or partially, at least four of the eight parameters.