Noha Ibrahim Shaaban

Dr. Noha Ibrahim Shaaban

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2023 in Separations
Verified
Journal Article
Open access
PDF file
HFHanan Farouk
Hanan Farouk
HEhager mohamed ebrahim
hager mohamed ebrahim
HSHeba Sonbol
Heba Sonbol
MMMonika Malak
Monika Malak
MKMaha Kamal
Maha Kamal
Samy EmaraSamy Emara
Samy Emara
Despite the fact that strong routine separation methodologies can give reliable specificity and validity at usual working pharmaceutical concentrations, they may fail at very low concentration levels. This poses considerable challenges for researchers investigating product purity and therapeutic drug monitoring. Sensitivity enhancement procedures are thus required to maximize the performance of separation techniques. Solid-phase extraction/solid-phase enrichment (SPE/SPEn) and pre-, post-, and in-column derivatization, as well as the use of sensitive detection devices, are the simplest strategies for improving sensitivity of separation-based analytical techniques. Large-volume injection of samples with online SPE/SPEn coupled with separation techniques increased sensitivity and improved detection as well as quantification limits without affecting peak shape and system performance. Although the primary purpose of derivatization is to improve sensitivity and selectivity, greener derivatization is growing in popularity and should be considered in analytical chemistry. In general, two strategies are essential for accomplishing greener derivatization goals. The first is the search for and use of ecologically acceptable derivatizing reagents, solvents, and reaction conditions. The second is miniaturization and automation of analytical methods. This review discusses significant advances in separation-based analytical techniques, specifically enrichment approaches and detector signal improvement for pharmaceutical quantification in various matrices at very low concentration levels. As a result of improved analytical systems setup in drug assays, the possibility of high-throughput analyses was also highlighted.

23 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AMabdelrahman Nabil maghraby
abdelrahman Nabil maghraby
HHHassan A Hendawy
Hassan A Hendawy
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
RARasha Ahmed
Rasha Ahmed
ASAhmed Shawky
Ahmed Shawky
NSNoha Ibrahim Shaaban
Noha Ibrahim Shaaban
A new green-validated and highly sensitive electrochemical method for the determination of molnupiravir (MOV) has been developed using cyclic voltammetry. The proposed analytical platform involves the use of a disposable laboratory-made screen-printed reduced graphene oxide 2.5% modified electrode (rGO-SPCE 2.5%) for the first time to measure MOV with high specificity. The surface morphology of the sensor was investigated by using a scanning electron microscope armed with an energy-dispersive X-ray probe. The fabricated sensor attained improved sensitivity when sodium dodecyl sulfate (SDS) surfactant (3 µM) was added to the supporting electrolyte solution of 0.04 M Britton–Robinson buffer at pH 2. The electrochemical activity of rGO-SPCE was examined in comparison with two different working electrodes in order to demonstrate that it was the most competitive sensor for MOV monitoring. The method was validated using differential pulse voltammetry according to ICH guidelines, resulting in good precision, accuracy, specificity, and robustness over a concentration range of 0.152–18.272 µM, with a detection limit of 0.048 µM. The stability investigation demonstrated that rGO-SPCE 2.5% can provide high-stability behavior towards the analyte throughout a six-week period under refrigeration. The fabricated rGO-SPCE 2.5% was successfully employed for the measurement of MOV in pharmaceutical capsules and human biofluids without the interference of endogenous matrix components as well as the commonly used excipient.

4 May 2021 in Pharmaceutical Chemistry Journal
Verified
Journal Article
Closed access
PDF file
SHSaid A. Hassan
Said A. Hassan
NSNoha Ibrahim Shaaban
Noha Ibrahim Shaaban
EEEman S. Elzanfaly
Eman S. Elzanfaly
AGAhmed E. El Gendy
Ahmed E. El Gendy


30 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
AMabdelrahman Nabil maghraby
abdelrahman Nabil maghraby
HHHassan A Hendawy
Hassan A Hendawy
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
RARasha Ahmed
Rasha Ahmed
ASAhmed Shawky
Ahmed Shawky
NSNoha Ibrahim Shaaban
Noha Ibrahim Shaaban
A new green-validated and highly sensitive electrochemical method for the determination of molnupiavir (MOV) has been developed using cyclic voltammetry. The proposed analytical platform involves the use of disposable screen-printed reduced graphene oxide 2.5% electrode (SPrGOE 2.5%) for the first time to measure MOV with high specificity. The surface morphology of the sensor was investigated by using a scanning electron microscope armed with an energy-dispersive X-ray probe. The fabricated sensor attains improved sensitivity when sodium dodecyl sulfate (SDS) surfactant was added to the supporting electrolyte solution. Thus, various factors were investigated in order to select the best supporting electrolyte for voltammetric determination of MOV, and the optimum conditions were achieved by employing 0.04 M Britton-Robinson at pH 2, 10-4 M SDS, and SPrGOE 2.5%. Well-defined MOV oxidation peaks were obtained with no reduction peaks in cyclic voltammetry using diffusion-controlled pathways. The method was validated using differential pulse voltammetry according to ICH guidelines, providing it to be precise, accurate, specific, and robust with linearity over a concentration range of 50-6017 ng/mL. The incorporation of the reduced graphene nanoparticles supported the in situ interaction between electrode surface and MOV, improved the selectivity, and reduced the detection limit to the concentration level of 15.98 ng/mL. The stability investigation demonstrated that SPrGOE 2.5% can provide high-stability behavior throughout a three-month period under refrigeration. The fabricated SPrGOE 2.5% was successfully employed for the measurement of MOV in pharmaceutical capsules and human bio-fluids without the interference of endogenous matrix components as well as the commonly used excipient.

8 May 2023 in Preprints.org
Verified
Preprint
Open access
HFHanan Farouk
Hanan Farouk
HEhager mohamed ebrahim
hager mohamed ebrahim
HSHeba Sonbol
Heba Sonbol
MMMonika Malak
Monika Malak
MKMaha Kamal
Maha Kamal
Samy EmaraSamy Emara
Samy Emara
Despite the fact that strong routine separation methodologies can give reliable specificity and validity at usual working pharmaceuticals concentrations, they may fail at very low concentration levels. This poses considerable challenges for researchers inves-tigating product purity and therapeutic drug monitoring. Sensitivity enhancement pro-cedures are thus required to maximize the performance of separation techniques. Large volume injection, solid phase extraction/solid phase enrichment (SPE/SPEn), pre-, post-, and in-column derivatization, as well as the use of sensitive detection devices are the simplest strategies for improving sensitivity of the separation-based analytical techniques. Large volume injection of samples with online SPE/SPEn coupled with separation techniques increased sensitivity and improved detection as well as quantification limits without affecting peak shape and system performance. Although the primary purpose of derivatization is to improve sensitivity and selectivity, greener derivatization is growing in popularity and should be considered in analytical chemistry. In general, two strategies are essential for accomplishing greener derivatization goals. The first is the search for and use of ecologically acceptable derivatizing reagents, solvents, and reaction conditions. The second is miniaturization and automation of analytical methods. This review discusses significant advances in separation-based analytical techniques, specifically enrichment approaches and detector signal improvement for pharmaceutical quantification in various matrices at very low concentration levels. As a result of improved analytical systems setup in drug assays, the possibility of high-throughput analyses was also highlighted.