Randa Ali Abdel Salam Moussa

Prof. Dr. Randa Ali Abdel Salam Moussa

Department of Pharmaceutical analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia 41522, Egypt
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
MAMohamed A. Abdelshakour
Mohamed A. Abdelshakour
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
GHGhada M. Hadad
Ghada M. Hadad
DADina M. Abo-ElMatty
Dina M. Abo-ElMatty
EHEMAN ALI. Abdel Hameed
EMAN ALI. Abdel Hameed
In recent times, the counterfeiting of pharmaceuticals has been considered a serious trouble especially in developing countries that acquire poor inspection programs. Sildenafil, vardenafil and tadalafil (phosphodiesterase type 5 inhibitors) products have gained wide popularity in treating sexual disorders, for which they are subjected to counterfeiting. For this purpose, a simple, rapid, and novel HPLC method with ultraviolet detection has been simply developed for the simultaneous determination of vardenafil, sildenafil, and tadalafil, and their counterfeits (dapoxetine, paroxetine, citalopram, tramadol and yohimbine) in pharmaceutical dosage forms and counterfeit products such as instant coffee and honey. The separation was carried out on a C18 column, with acetonitrile and an aqueous 0.05% formic acid solution as the mobile phase with a gradient program and at a flow rate of 1 mL min−1. UV detection was accurately set at 230 nm. The total run time was 11 min for elution of these eight drugs. A UPLC-MS/MS method was also developed, by which compounds were separated in only 6 min, and it was used as a confirmatory tool for studied compounds by identification of their mass spectra. Proposed methods were validated by following ICH guidelines. Both methods were found to be linear, specific, precise and accurate, and they were efficiently applied to analyze 50 commercial products including honey sachets, instant coffee and pharmaceutical products marketed as aphrodisiacs and suspected to contain PDE5-inhibitors.

23 April 2012 in Journal of Chromatographic Science
Verified
Journal Article
Open access
PDF file
GHGhada M. Hadad
Ghada M. Hadad
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
Samy EmaraSamy Emara
Samy Emara
A high-performance liquid chromatographic method was optimized and validated for the determination of desacetyl nitazoxanide (tizoxanide), the main active metabolite of nitazoxanide in human plasma, urine and breast milk. The proposed method used a CN column with mobile phase consisting of acetonitrile–12mM ammonium acetate–diethylamine in the ratio of 30:70:0.1 (v/v/v) and buffered at pH 4.0 with acetic acid, with a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 260 nm using nifuroxazide as internal standard. A simplified direct injection of urine samples without extraction in addition to the urinary excretion pattern were calculated using the proposed method. Also, the effectiveness of protein precipitation and a clean-up procedure were investigated for biological plasma and human breast milk samples. The validation study of the proposed method was successfully carried out in an assay range between 0.2 and 20 µg/mL.

28 February 2008 in Journal of Separation Science
Verified
Journal Article
Closed access
PDF file
AEAlaa El‐Gindy
Alaa El‐Gindy
SSShehab Sallam
Shehab Sallam
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa

23 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AMabdelrahman Nabil maghraby
abdelrahman Nabil maghraby
HHHassan A Hendawy
Hassan A Hendawy
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
RARasha Ahmed
Rasha Ahmed
ASAhmed Shawky
Ahmed Shawky
NSNoha Ibrahim Shaaban
Noha Ibrahim Shaaban
A new green-validated and highly sensitive electrochemical method for the determination of molnupiravir (MOV) has been developed using cyclic voltammetry. The proposed analytical platform involves the use of a disposable laboratory-made screen-printed reduced graphene oxide 2.5% modified electrode (rGO-SPCE 2.5%) for the first time to measure MOV with high specificity. The surface morphology of the sensor was investigated by using a scanning electron microscope armed with an energy-dispersive X-ray probe. The fabricated sensor attained improved sensitivity when sodium dodecyl sulfate (SDS) surfactant (3 µM) was added to the supporting electrolyte solution of 0.04 M Britton–Robinson buffer at pH 2. The electrochemical activity of rGO-SPCE was examined in comparison with two different working electrodes in order to demonstrate that it was the most competitive sensor for MOV monitoring. The method was validated using differential pulse voltammetry according to ICH guidelines, resulting in good precision, accuracy, specificity, and robustness over a concentration range of 0.152–18.272 µM, with a detection limit of 0.048 µM. The stability investigation demonstrated that rGO-SPCE 2.5% can provide high-stability behavior towards the analyte throughout a six-week period under refrigeration. The fabricated rGO-SPCE 2.5% was successfully employed for the measurement of MOV in pharmaceutical capsules and human biofluids without the interference of endogenous matrix components as well as the commonly used excipient.

4 May 2023 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
PDF file
AMAziza E. Mostafa
Aziza E. Mostafa
MEMaya S Eissa
Maya S Eissa
AEAhmed Elsonbaty
Ahmed Elsonbaty
Khaled AttalaKhaled Attala
Khaled Attala
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
MAMohamed A Abdelshakour
Mohamed A Abdelshakour
Computationally-designed molecular imprinted polymers (MIP) incorporation into electrochemical sensors has many advantages to the performance of the designed sensors. The innovative self-validated ensemble modeling (SVEM) approach is a smart machine learning-based technique that enabled the design of more accurate predictive models utilizing smaller data sets. The novel SVEM experimental design methodology is exploited here exclusively to optimize the composition of four eco-friendly PVC membranes augmented by a computationally designed magnetic molecularly imprinted polymer to quantitatively determine drotaverine hydrochloride in its combined dosage form and human plasma. Besides, the application of hybrid computational simulations such as molecular dynamics and quantum mechanical calculations (MD/QM) is a time-saving and eco-friendly provider for the tailored design of the MIP particles. Here, for the first time, the predictive power of machine learning is assembled with computational simulations to develop four PVC-based sensors decorated by computationally designed MIP particles utilizing four different experimental designs known as central composite, SVEM-LASSO, SVEM-FWD, and SVEM-PFWD. The pioneering Agree approach further assessed the greenness of the analytical methods, proving their eco-friendliness. The proposed sensors showed decent Nernstian responses towards drotaverine hydrochloride in the range of (58.60—59.09 mV/decade) with a linear quantitative range of (1 x 10−7—1 x 10−2 M) and limits of detection in the range of (9.55 x 10−8 – 7.08 x 10−8 M). Moreover, the proposed sensors showed ultimate eco-friendliness and selectivity for their target in its combined dosage form and spiked human plasma. The proposed sensors were validated as per IUPAC recommendations proving their sensitivity and selectivity for drotaverine determination in dosage form and human plasma. This work presents the first ever application of both the innovative SVEM designs and MD/QM simulations in the optimization and fabrication of drotaverine-sensitive and selective MIP-decorated PVC sensors.

2 May 2023 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
ARAya Roshdy
Aya Roshdy
Randa Ali Abdel Salam MoussaRanda Ali Abdel Salam Moussa
Randa Ali Abdel Salam Moussa
GHGhada Hadad
Ghada Hadad
FBFathallah Belal
Fathallah Belal
HEHeba El-Mansi
Heba El-Mansi
For the simultaneous estimation of two co-formulated antihistaminic drugs (Bilastine and Montelukast), a novel and eco-friendly reversed-phase HPLC approach with both diode array and fluorescence detection modes was designed. Rather than using the routine methodology, the Quality by Design (QbD) approach was adopted to speed up the method development and to test robustness of the method. To evaluate the effect of variable factors on chromatographic response, a full factorial design was used. The chromatographic separation was performed using isocratic elution on the C18 column. The mobile phase consists of 92% methanol, 6% acetonitrile, and 2% phosphate buffer with 0.1 (v/v) triethylamine adjusted to pH 3, it was pumped at a flow rate of 0.8 mL/min with an injection volume of 20 μL. The developed stability indicating HPLC approach was used to assess the stability of montelukast (MNT). It was subjected to a variety of stress conditions, including hydrolytic (acid–base), oxidative, thermal, and photolytic stress conditions. All of these conditions were found to have relevant degradation pathways. Under the described experimental conditions, MNT degradation followed pseudo-first-order kinetics. The kinetic parameters of its degradation (rate constant and t1/2) were calculated and a proposal for the degradation pathway was postulated.