Małgorzata Śmiałek-Telega

Dr. Małgorzata Śmiałek-Telega


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2016 in Cancer Nanotechnology
Verified
Journal Article
Open access
PDF file
KHKaspar Haume
Kaspar Haume
SRSoraia Rosa
Soraia Rosa
SGSophie Grellet
Sophie Grellet
Małgorzata Śmiałek-TelegaMałgorzata Śmiałek-Telega
Małgorzata Śmiałek-Telega
Karl ButterworthKarl Butterworth
Karl Butterworth
NMNigel J. Mason
Nigel J. Mason
Radiotherapy is currently used in around 50% of cancer treatments and relies on the deposition of energy directly into tumour tissue. Although it is generally effective, some of the deposited energy can adversely affect healthy tissue outside the tumour volume, especially in the case of photon radiation (gamma and X-rays). Improved radiotherapy outcomes can be achieved by employing ion beams due to the characteristic energy deposition curve which culminates in a localised, high radiation dose (in form of a Bragg peak). In addition to ion radiotherapy, novel sensitisers, such as nanoparticles, have shown to locally increase the damaging effect of both photon and ion radiation, when both are applied to the tumour area. Amongst the available nanoparticle systems, gold nanoparticles have become particularly popular due to several advantages: biocompatibility, well-established methods for synthesis in a wide range of sizes, and the possibility of coating of their surface with a large number of different molecules to provide partial control of, for example, surface charge or interaction with serum proteins. This gives a full range of options for design parameter combinations, in which the optimal choice is not always clear, partially due to a lack of understanding of many processes that take place upon irradiation of such complicated systems. In this review, we summarise the mechanisms of action of radiation therapy with photons and ions in the presence and absence of nanoparticles, as well as the influence of some of the core and coating design parameters of nanoparticles on their radiosensitisation capabilities.

9 January 2012 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
Małgorzata Śmiałek-TelegaMałgorzata Śmiałek-Telega
Małgorzata Śmiałek-Telega
MHM.-J. Hubin-Franskin
M.-J. Hubin-Franskin
JDJ. Delwiche
J. Delwiche
DDD. Duflot
D. Duflot
NMN. J. Mason
N. J. Mason
PLPaulo LIMÃO-VIEIRA
Paulo LIMÃO-VIEIRA
Electronic state spectroscopy of limonene has been investigated using vacuum ultraviolet photoabsorption spectroscopy in the energy range 5.0–10.8 eV. The availability of a high resolution photon beam (∼0.075 nm) enabled detailed analysis of the vibrational progressions and allowed us to propose, for the first time, new assignments for several Rydberg series. Excited states located in the 7.5–8.4 eV region have been studied for the first time. A He(I) photoelectron spectrum has also been recorded from 8.2 to 9.5 eV and compared to previous low resolution works. A new value of 8.521 ± 0.002 eV for the ground ionic state adiabatic ionisation energy is proposed. Absolute photoabsorption cross sections were derived in the 10–26 eV range from electron scattering data. All spectra presented in this paper represent the highest resolution data yet reported for limonene. These experiments are complemented by new ab initio calculations performed for the three most abundant conformational isomers of limonene, which we then used in the assignment of the spectral bands.

24 June 2013 in Physical Review E
Verified
Journal Article
Closed access
Małgorzata Śmiałek-TelegaMałgorzata Śmiałek-Telega
Małgorzata Śmiałek-Telega
NJNykola C. Jones
Nykola C. Jones
SHSøren Vrønning Hoffmann
Søren Vrønning Hoffmann
NMNigel J. Mason
Nigel J. Mason
In order to determine a proper value for the density of dry DNA films we have used a method based upon the measurement of interference effects in transmission spectra of thin DNA layers. Our results show that the methodology is effective and the density of DNA in this state, 1.407 g/cm${}^{3}$, is much lower than the commonly used 1.7 g/cm${}^{3}$. Obtaining accurate values for the DNA film density will allow the optical constants for DNA to be recalculated, which were previously obtained assuming a higher DNA density. Furthermore, since our recent investigations have shown a strong dependence of the sample composition on DNA film formation and thus on its density, such a method will be important in characterizing particle interactions with DNA film and their dose dependence.

25 February 2016 in The European Physical Journal D
Verified
Journal Article
Open access
PDF file
Małgorzata Śmiałek-TelegaMałgorzata Śmiałek-Telega
Małgorzata Śmiałek-Telega
MMMichael A. MacDonald
Michael A. MacDonald
SPSylwia Ptasińska
Sylwia Ptasińska
LZLucia Zuin
Lucia Zuin
NMNigel J. Mason
Nigel J. Mason
The pyridine molecule has been examined by the means of photoelectron and threshold photoelectron spectroscopies. Ionization energies were determined for b

1 November 2009 in Radiation Research
Verified
Journal Article
Closed access
Małgorzata Śmiałek-TelegaMałgorzata Śmiałek-Telega
Małgorzata Śmiałek-Telega
SMSharon A. Moore
Sharon A. Moore
NMNigel J. Mason
Nigel J. Mason
DSDavid E. G. Shuker
David E. G. Shuker
To accurately quantify the number of single-strand breaks (SSBs) induced in plasmid DNA molecules after irradiation, a new type of assay methodology has been explored. The new method is based on the TUNEL (terminal deoxynucleotide transferase dUTP nick end-labeling) assay that was adopted for use under ELISA (enzyme-linked immunosorbent assay) conditions. The assay was found to both improve the quantification and reduce the uncertainties in measurement of SSBs compared with the commonly used agarose gel electrophoresis (AGE) method. Together with AGE, the new method can provide the additional data necessary for an accurate analysis of both SSB and double-strand break (DSB) formation in DNA molecules after irradiation. Furthermore, since only small amounts of DNA are required, the ELISA method can be used to quantify the damage in samples of DNA that are smaller than those required for AGE analysis. As an example of the data obtainable using the new method, plasmid DNA samples were irradiated with vacuum-ultraviolet (VUV) light in an aqueous solution at 170 nm and subsequently analyzed by ELISA. The results were compared directly with those from AGE analysis. The ELISA gave results for SSBs that were an order of magnitude higher than those from AGE and suggested that DSBs are more likely to be the result of two SSBs rather than a single event and that a damaged molecule is more likely to be susceptible to VUV light than an undamaged one.

30 March 2010 in The European Physical Journal D
Verified
Journal Article
Closed access
PDF file
Małgorzata Śmiałek-TelegaMałgorzata Śmiałek-Telega
Małgorzata Śmiałek-Telega
RBR. Balog
R. Balog
NJN. C. Jones
N. C. Jones
DFD. Field
D. Field
NMN. J. Mason
N. J. Mason