To incorporate the effects of low energy electrons and positrons into radiation interaction models. The simulation method proposed here was based on experimental and theoretical cross section data and energy loss spectra we have previously derived. After a summary of the main techniques used to obtain reliable input data, the basis of a Low Energy Particle Track Simulation (LEPTS) procedure was established. The programme is specifically designed to describe electron and positron interactions below 10 keV, down to thermal energies. Single electron and positron tracks in water are presented and the possibility of using these results to develop tools for nanodosimetry is discussed. Standard approximations based on high incident energies, such as the Born-Bethe theory, are not suitable to simulate electron and positron tracks below 10 keV. Prior to the inclusion of low-energy effects in a radiation model, an appropriate study is required to determine both the interaction cross sections and the energy loss spectra.
15 April 2014 in IEEE Transactions on Biomedical Engineering
We present the modeling efforts on antenna design and frequency selection to monitor brain temperature during prolonged surgery using noninvasive microwave radiometry. A tapered log-spiral antenna design is chosen for its wideband characteristics that allow higher power collection from deep brain. Parametric analysis with the software HFSS is used to optimize antenna performance for deep brain temperature sensing. Radiometric antenna efficiency (η) is evaluated in terms of the ratio of power collected from brain to total power received by the antenna. Anatomical information extracted from several adult computed tomography scans is used to establish design parameters for constructing an accurate layered 3-D tissue phantom. This head phantom includes separate brain and scalp regions, with tissue equivalent liquids circulating at independent temperatures on either side of an intact skull. The optimized frequency band is 1.1–1.6 GHz producing an average antenna efficiency of 50.3% from a two turn log-spiral antenna. The entire sensor package is contained in a lightweight and low-profile 2.8 cm diameter by 1.5 cm high assembly that can be held in place over the skin with an electromagnetic interference shielding adhesive patch. The calculated radiometric equivalent brain temperature tracks within 0.4 °C of the measured brain phantom temperature when the brain phantom is lowered 10 °C and then returned to the original temperature (37 °C) over a 4.6-h experiment. The numerical and experimental results demonstrate that the optimized 2.5-cm log-spiral antenna is well suited for the noninvasive radiometric sensing of deep brain temperature.
In this paper, we report on total electron tetrahydrofuran scattering cross-section measurements for energies in the range from 50 to 5000 eV with experimental errors of about 5%. In addition, integral elastic and inelastic cross sections have been calculated over a broad energy range , with an optical potential method assuming a screening-corrected independent atom representation. Partial and total ionization cross sections have been also obtained by combining simultaneous electron and ion measurements with a time-of-flight analysis of the ionic induced fragmentation. Finally, an average energy distribution of secondary electrons has been derived from these measurements in order to provide data for modeling electron-induced damage in biomolecular systems.