Zigmārs Zundāns

Mr. Zigmārs Zundāns

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2023 in Buildings
Verified
Journal Article
Open access
PDF file
RFRitvars Freimanis
Ritvars Freimanis
RVRuta Vanaga
Ruta Vanaga
VBViesturs Balodis
Viesturs Balodis
ZZZigmārs Zundāns
Zigmārs Zundāns
ABAndra Blumberga
Andra Blumberga
Energy efficiency renovation of building stock is an essential aspect of the climate change mitigation strategies in many countries. A large proportion of building stock is historical buildings. For this building stock, developing technology for safe internal insulation of external walls is crucial, preventing possible moisture damage to the building structures. Internal insulation is a risky technique as it has a high impact on the hygrothermal behavior of the wall. This study assesses the hygrothermal performance of massive masonry walls with 17 interior insulation systems exposed to different external boundary conditions, including a steady-state cycle, dynamic dry cycle, wind-driven cycle, and drying cycle. During the steady state cycle, the highest increase of moisture was observed under capillary active materials ranging from 39 to 119% increase in absolute moisture, with the exception of cellulose with an increase of only 7%. All the vapor-tight insulation systems showed no increase in absolute moisture during the steady-state cycle, with the exception being mineral wool in combination with a vapor barrier that showed a 30% increase in ablute humidity. In addition, relative moisture changes in masonry were measured. Results show that tested insulation systems exhibit similar thermal performance while having different moisture performance. Vapor-tight and vapor-open insulation systems exhibit different hygrothermal behavior under various test cycles depending on material vapor diffusion resistance. Numerical simulations are sensitive to the hygrothermal properties of materials.

7 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
RVRuta Vanaga
Ruta Vanaga
JNJānis Narbuts
Jānis Narbuts
RFRitvars Freimanis
Ritvars Freimanis
ZZZigmārs Zundāns
Zigmārs Zundāns
ABAndra Blumberga
Andra Blumberga
To meet the 2050 EU decarbonization goals, there is a need for new and innovative ideas to increase energy efficiency, which includes reducing the energy consumption of buildings and increasing the use of on-site renewable energy sources. One possible solution for achieving efficient thermal energy transition in the building sector is to assign new functionalities to the building envelope. The building envelope can function as a thermal energy storage system, which can help compensate for irregularities in solar energy availability. This can be accomplished by utilizing phase change materials as the energy storage medium in the building envelope. In this paper, two phase change materials with different melting temperatures of 21 °C and 28 °C are compared for their application in a dynamic solar building envelope. Both experimental and numerical studies were conducted within the scope of this study. The laboratory testing involved simulating the conditions of the four seasons through steady-state and dynamic experiments. The performance of the phase change materials was evaluated using a small-scale PASLINK test stand that imitates indoor and outdoor conditions. A numerical model of a small-scale building envelope was created using data from laboratory tests. The purpose of this model was to investigate how the tested phase change materials perform under different climate conditions. The experimental findings show that RT21HC is better at storing thermal energy in the PCM and releasing it into the indoor area than RT28HC. On the other hand, the numerical simulation results demonstrate that RT28HC has an advantage in terms of thermal storage capacity in climates found in Southern Europe, as it prevents overheating of the room.

13 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
GBGirts Bohvalovs
Girts Bohvalovs
AKAntra Kalnbaļķīte
Antra Kalnbaļķīte
IPIeva Pakere
Ieva Pakere
RVRuta Vanaga
Ruta Vanaga
VKVladimirs Kirsanovs
Vladimirs Kirsanovs
ABAndra Blumberga
Andra Blumberga
A vital component of achieving climate neutrality in the future involves bolstering energy efficiency measures in educational institutions and improving the overall knowledge on sustainable solutions. To achieve fruitful outcomes, the active involvement of various stakeholders, such as managers, teaching staff, and students, is indispensable. By implementing energy-efficient building systems, advancing the use of renewable energy sources, and incorporating sustainable practices into the curriculum, educational institutions can decrease their environmental impact and conserve resources for future generations. Active participation from all stakeholders, including managers, teaching staff, and students, is essential for the success of these efforts. Providing students with a comprehensive education on sustainability equips them to apply this knowledge in their future professions, thus contributing to a more sustainable society. To gain insights into the existing state of sustainability within educational systems, a comprehensive study of educational institutions was undertaken. To assess and compare schools’ sustainability, a composite indicator was developed. The study’s findings reveal that the implementation of mandatory and optional measures can lead to a substantial reduction in primary energy consumption by 39% and greenhouse gas emissions by 34% in educational institutions. The average abandonment costs for mandatory measures are 5.87 EUR/kgCO2/year, but the average value for optional measures is 33.80 EUR/kgCO2/year. It is suggested demonstration projects be implemented in institutions where specialists in RE, mechatronics, building engineering systems, and environmental technologies are trained by showcasing technologies needed for the transition to climate neutrality.

6 October 2023 in Buildings
Verified
Journal Article
Open access
PDF file
RFRitvars Freimanis
Ritvars Freimanis
ABAndra Blumberga
Andra Blumberga
RVRuta Vanaga
Ruta Vanaga
ZZZigmārs Zundāns
Zigmārs Zundāns
Energy consumption in historic building stock is high compared to current energy efficiency standards. The heritage value of the façade and the limited space on the external surface in densely populated urban streets limit the application of external insulation. Internal insulation can be applied instead. However, it is considered to be a riskier technology due to moisture-related damage. In addition to mold growth and wood rot, frost damage should be considered in cold climates. This study aims to assess the impact of a vapor-open capillary-active calcium silicate internal insulation system with and without adhesive glue on the hygrothermal behavior of masonry from various historic bricks in cold climates by performing numerical simulations in the software Delphin. Test results of hygrothermal properties of 40 historic brick samples were used in numerical experiments to assess the impact of a brick type, the quality of the application of calcium silicate (with or without adhesive), and the impact of cold climate on the hygrothermal behavior. Results show that temperature behavior is similar to all wall types whereas a large difference is observed in moisture behavior. The application of adhesive glue tends to reduce moisture spikes caused by rain events when compared to the same samples without adhesive. Findings only partly correspond to other studies on factors affecting moisture behavior.