Ritvars Freimanis

Mr. Ritvars Freimanis

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2023 in Buildings
Verified
Journal Article
Open access
PDF file
RFRitvars Freimanis
Ritvars Freimanis
RVRuta Vanaga
Ruta Vanaga
VBViesturs Balodis
Viesturs Balodis
ZZZigmārs Zundāns
Zigmārs Zundāns
ABAndra Blumberga
Andra Blumberga
Energy efficiency renovation of building stock is an essential aspect of the climate change mitigation strategies in many countries. A large proportion of building stock is historical buildings. For this building stock, developing technology for safe internal insulation of external walls is crucial, preventing possible moisture damage to the building structures. Internal insulation is a risky technique as it has a high impact on the hygrothermal behavior of the wall. This study assesses the hygrothermal performance of massive masonry walls with 17 interior insulation systems exposed to different external boundary conditions, including a steady-state cycle, dynamic dry cycle, wind-driven cycle, and drying cycle. During the steady state cycle, the highest increase of moisture was observed under capillary active materials ranging from 39 to 119% increase in absolute moisture, with the exception of cellulose with an increase of only 7%. All the vapor-tight insulation systems showed no increase in absolute moisture during the steady-state cycle, with the exception being mineral wool in combination with a vapor barrier that showed a 30% increase in ablute humidity. In addition, relative moisture changes in masonry were measured. Results show that tested insulation systems exhibit similar thermal performance while having different moisture performance. Vapor-tight and vapor-open insulation systems exhibit different hygrothermal behavior under various test cycles depending on material vapor diffusion resistance. Numerical simulations are sensitive to the hygrothermal properties of materials.

12 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
ABAndra Blumberga
Andra Blumberga
RFRitvars Freimanis
Ritvars Freimanis
EBEdite Biseniece
Edite Biseniece
AKAgris Kamenders
Agris Kamenders
In most cases, internal insulation is the only solution to improve the energy efficiency of historic buildings. However, it is one of the most challenging and complex energy efficiency measures due to changes in boundary conditions and hygrothermal behavior of the wall, particularly in cold climates. This study presents the long-term monitoring of the hygrothermal performance of an internally insulated historic stone wall building. The study aimed to assess the hygrothermal behavior of the dolomite wall if mineral wool insulation is applied internally on the north-east wall in the rooms with and without high internal moisture load. The measurements included temperature, relative humidity, water content, and heat flux. Monitoring results are compared with 1D hygrothermal simulations and a building energy consumption simulation. The in situ measurement results and hygrothermal assessment shows energy consumption decreased by 55% with relative humidity under the insulation staying belove 60% for most of the time, with short periods of increase over 80%. Energy consumption simulation shows an energy saving potential of up to 72% in the case of proper energy management.

1 March 2018 in Environmental and Climate Technologies
Verified
Journal Article
Open access
EBEdite Biseniece
Edite Biseniece
RFRitvars Freimanis
Ritvars Freimanis
RPReinis Purvins
Reinis Purvins
AGArmands Gravelsins
Armands Gravelsins
APAivars Pumpurs
Aivars Pumpurs
ABAndra Blumberga
Andra Blumberga
Being an important contributor to the final energy consumption, historic buildings built before 1945 have high specific heating energy consumption compared to current energy standards and norms. However, they often cannot be insulated from the outside due to their heritage and culture value. Internal insulation is an alternative. However internal insulation faces challenges related to hygrothermal behaviour leading to mold growth, freezing, deterioration and other risks. The goal of this research is to link hygrothermal simulation results with experimental results for internally insulated historic brick masonry to assess correlation between simulated and measured data as well as the most influential parameters. The study is carried out by both a mathematical simulation tool and laboratory tests of historic masonry with internal insulation with four insulation materials (mineral wool, EPS, wood fiber and granulated aerogel) in a cold climate (average 4000 heating degree days). We found disparity between measured and simulated hygrothermal performance of studied constructions due to differences in material parameters and initial conditions of materials. The latter plays a more important role than material parameters. Under a steady state of conditions, the condensate tolerating system varies between 72.7 % and 80.5 % relative humidity, but in condensate limiting systems relative humidity variates between 73.3 % and 82.3 %. The temperature between the masonry wall and all insulation materials has stabilized on average at +10 °C. Mold corresponding to Mold index 3 was discovered on wood fiber mat.

7 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
RVRuta Vanaga
Ruta Vanaga
JNJānis Narbuts
Jānis Narbuts
RFRitvars Freimanis
Ritvars Freimanis
ZZZigmārs Zundāns
Zigmārs Zundāns
ABAndra Blumberga
Andra Blumberga
To meet the 2050 EU decarbonization goals, there is a need for new and innovative ideas to increase energy efficiency, which includes reducing the energy consumption of buildings and increasing the use of on-site renewable energy sources. One possible solution for achieving efficient thermal energy transition in the building sector is to assign new functionalities to the building envelope. The building envelope can function as a thermal energy storage system, which can help compensate for irregularities in solar energy availability. This can be accomplished by utilizing phase change materials as the energy storage medium in the building envelope. In this paper, two phase change materials with different melting temperatures of 21 °C and 28 °C are compared for their application in a dynamic solar building envelope. Both experimental and numerical studies were conducted within the scope of this study. The laboratory testing involved simulating the conditions of the four seasons through steady-state and dynamic experiments. The performance of the phase change materials was evaluated using a small-scale PASLINK test stand that imitates indoor and outdoor conditions. A numerical model of a small-scale building envelope was created using data from laboratory tests. The purpose of this model was to investigate how the tested phase change materials perform under different climate conditions. The experimental findings show that RT21HC is better at storing thermal energy in the PCM and releasing it into the indoor area than RT28HC. On the other hand, the numerical simulation results demonstrate that RT28HC has an advantage in terms of thermal storage capacity in climates found in Southern Europe, as it prevents overheating of the room.

1 January 2020 in Environmental and Climate Technologies
Verified
Journal Article
Open access
PDF file
DJDzintars Jaunzems
Dzintars Jaunzems
IPIeva Pakere
Ieva Pakere
SASigne Allena-Ozoliņa
Signe Allena-Ozoliņa
RFRitvars Freimanis
Ritvars Freimanis
ABAndra Blumberga
Andra Blumberga
GBGatis Bazbauers
Gatis Bazbauers
National energy sector management differs from country to country. Therefore, it is important to develop country-specific energy models to analyse the energy demand, structure and potential policy instruments. The paper presents a pathway for adaption and improvement of the standard TIMES model structure to the specific country requirements. The analysis is based on a three-sector (industrial, commercial and residential) case study of Latvia. Literature review presents experience of other research when developing different energy models as well as adapting the TIMES model structure. The main results show a distribution of the final energy consumption and the validation of the obtained results of the sectors studied. Method and intermediate results presented in the paper are part of an ongoing modelling process of Latvia’s energy sector.

1 January 2021 in Environmental and Climate Technologies
Verified
Journal Article
Open access
PDF file
JNJanis Narbuts
Janis Narbuts
RVRuta Vanaga
Ruta Vanaga
RFRitvars Freimanis
Ritvars Freimanis
ABAndra Blumberga
Andra Blumberga
Buildings are linked to a significant untapped energy saving potential, accounting for 40 % of European Union’s (EU) final energy and 36 % of CO2 emissions. Energy efficient building envelopes plays the key role to achieve decarbonization of the EU’s building stock by 2050. Active building envelopes are emerging and novel trend offering the paradigm shift in perception of building enclosures. Paper presents study of active solar façade containing phase change material for energy storage. Study seeks for optimisation of solar façade module by introducing dynamic component and variating in the composition of module itself to ensure faster energy harvesting and minimise the heat losses at discharging phase. Comparative tests were carried out in laboratory, in controlled heating and cooling conditions to evaluate impact of dynamic component. The dynamic component has reflective inner coating that focuses solar radiation on the element in heating phase and aerogel insulation filling in the blades that decreases heat loss in the cooling phase. Varying components in the design were used– thickness of aerogel insulation, Fresnel lens and width of concentrating cone diameter. Wide range of phase change material average temperature was observed 24 °C in setups with full aerogel filling to 50 °C in setup Fresnel lens. Average temperature in phase change material was reached higher in all setups with dynamic component compared to identical setups without dynamic component. Temperature differences were in the range from 1 °C in aerogel filled setups till 6 °C in setups with Fresnel lens.