We investigate the generation of high repetition frequency electron beam from vacuum arc plasma source, which consists of Cu cathode and hollow anode. The frequency and pulse width of the extraction pulse power supply based on MOSFET can be adjusted continuously. A self-trigger circuit is designed to immediately reignite DC arc after its extinguishment and guarantee the discharge duration time and stability. The experimental results show that the repletion frequency and pulse width of the electron beam are controlled by the extraction pulse voltage parameters. With a certain discharge current, the beam current increases with the increasing extraction voltage and shows a saturation limit up to 1A. However, the extraction voltage with too high pulse frequency or pulse width is not conducive to the stability of the beam current.
Under light load conditions, the phase-shifted full-bridge (PSFB) converter often has difficulty in realizing the zero-voltage switching (ZVS) of the lagging-leg by relying on the energy of its resonant inductor; however, for the series-parallel PSFB converter applied in high-power applications, the lagging-leg still has the problem of difficult realization of ZVS. Based on this, the paper analyzes the reasons why the series-parallel PSFB converter has difficulty in achieving ZVS for the lagging-leg under light and heavy loads. Under interleaved control, the ZVS of the lagging-leg over the full load range is realized by adding an auxiliary LC branch at the midpoint of the lagging-leg of both submodules. Based on the double-bridge input-parallel-output-series (IPOS) PSFB converter, analyzing the working principle of the circuit after adding the auxiliary LC branch and extending it to the series-parallel PSFB converter. The design requirements of the LC auxiliary branch of the dual-bridge series-parallel PSFB converter are given and the effects of the LC auxiliary branch on the module operating state and device stress are analyzed. On this basis, an extension is carried out to give the working principle and design method of the auxiliary LC branch of the N-bridge series-parallel PSFB converter. Finally, a 100 kW Matlab/Simulink simulation model verifies the superior performance of the proposed LC auxiliary branch to realize the lagging-leg ZVS of the series-parallel PSFB converter under light and heavy loads and achieves a 1.09% peak efficiency improvement at rated load.
Against the background of carbon peak and carbon neutralization, in order to solve the problem of poor flexibility of integrated energy systems and wind power consumption while improving the potential of hydrogen energy emission reduction, this study proposes an integrated energy system that takes into account the coupling of concentrating solar power (CSP), hydrogen-doped combustion, and power-to-gas (P2G) conversion. Firstly, a mathematical model of a CSP-CHP unit is established by introducing a CSP power station, aiming at the defect of the “heat to power” mode in the CHP system. Secondly, the energy consumption of P2G hydrogen energy production is satisfied by surplus wind power. The utilization stage of hydrogen energy is divided into supply CHP combustion and CO2 methanation, forming a CSP-P2G-HCHP collaborative framework and establishing an IES low-carbon economic dispatch model with CSP-P2G-HCHP. At the same time, the carbon trading mechanism is introduced to constrain the carbon emissions of the system. Finally, an optimization strategy with the minimum sum of the operation and maintenance cost, the energy purchase cost, the wind curtailment cost, and the carbon emission cost as the objective function is proposed, and the CPLEX solver is used to solve and carry out multi-case analysis. The simulation results show that the carbon emissions are reduced by 6.34%, the wind curtailment cost is reduced by 52.2%, and the total cost is reduced by 1.67%. The model takes into account the carbon reduction effect and operating efficiency and effectively improves the new energy consumption capacity.
Parasitic oscillations in the rectifier diode voltage of phase-shifted-full-bridge (PSFB) converters limit their application in high-voltage and high-power situations. The conventional analysis method for parasitic oscillation in rectifier diode voltage in PSFB converters treats the filter inductor as a constant current source and fails to consider the impact of changes in filter inductor current on the rectifier diode’s parasitic oscillation. Consequently, this approach does not apply when analyzing the rectifier diode voltage’s parasitic oscillations in high-power PSFB converters employing an input-parallel output-series (IPOS) configuration with interleaved drive. This research paper introduces an innovative equivalent circuit model for analyzing the parasitic oscillations of rectifier diode voltage in IPOS high-power PSFB converters. The model takes into account the mutual influence of rectifier diode voltage oscillations between submodules under interleaved control, considering the influence of changes in filter inductor current on rectifier diode parasitic oscillation. Based on the circuit model, we explain the mechanism of multiple oscillations of the rectifier diode voltage and the reason for the high peak of the first oscillation. Consequently, the interplay of rectifier diode voltage oscillations in IPOS high-power k-module PSFB converters under interleaved control is analyzed. To mitigate the adverse effects of rectifier diode voltage parasitic oscillation, a buffering strategy involving the connection of a resistor capacitor diode (RCD) circuit in parallel after the rectifier bridge is adopted, considering the structure of the IPOS high-power PSFB converter. The study provides a detailed analysis of the circuit’s operation mechanism upon incorporating the RCD buffer circuit and establishes the relationship between buffer capacitance, resistance, and spike voltage. Furthermore, a design method for buffer capacitors and discharge resistors in buffer circuits is presented. Finally, a 100 kW prototype is tested to verify the rectifier diode voltage oscillation mechanism of the IPOS high-power PSFB converter and the rationality of the buffer capacitor and discharge resistor design method under the interleaved drive approach.
Single-phase grounding is the dominant fault type in urban power distribution networks. Because the total magnetic flux would not change around the cable under a single-phase grounding fault, ferromagnetic zero-sequence current sensors cannot distinguish the faulted phase of belted cables, which are the main type in 10 kV distribution networks. To fill this gap, a two-step methodology is proposed using an annular TMR magnetic sensor to measure the magnetic field intensity at six points on the cable surface and to distinguish the faulted phase using the magnetic field intensity differences between the TMRs. The first step is calculating the rotation angles between the six magnetic sensors and the three cable cores after installation. A differential evolution algorithm is used to calculate the rotation angles in the sensing model. The second step is to detect the fault phase under a single-phase grounding fault transient, with the magnetic field intensity difference taken as the criterion. The methodology is verified through simulation and experiment. The results show that the relative errors of the rotation angles are all less than 1%. Under a single-phase grounding fault, the faulted phase can be accurately identified. The proposed method can effectively identify the faulted phase of 10 kV three-core cables under single-phase grounding and has significant engineering application value.