Martin Zeilinger

Dr. Martin Zeilinger

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2020 in European Radiology
Verified
Journal Article
Open access
PDF file
MZMartin Zeilinger
Martin Zeilinger
MWMarco Wiesmüller
Marco Wiesmüller
CFChristoph Forman
Christoph Forman
MSMichaela Schmidt
Michaela Schmidt
CMCamila Munoz
Camila Munoz
WWWolfgang Wuest
Wolfgang Wuest
Objectives: To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. Material and methods: Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI. Overall subjective image quality, LGE pattern and extent, diagnostic confidence for detection of LGE, and scan time were evaluated and compared to standard 2D LGE imaging. Robustness of Dixon fat suppression was evaluated for 3D Dixon LGE imaging. For statistical analysis, the non-parametric Wilcoxon rank sum test was performed. Results: LGE was rated as ischemic in 9 patients and non-ischemic in 11 patients while it was absent in 20 patients. Image quality and diagnostic confidence were comparable between both techniques (p = 0.67 and p = 0.66, respectively). LGE extent with respect to segmental or transmural myocardial enhancement was identical between 2D and 3D (water-only and in-phase). LGE size was comparable (3D 8.4 ± 7.2 g, 2D 8.7 ± 7.3 g, p = 0.19). Good or excellent fat suppression was achieved in 93% of the 3D LGE datasets. In 6 patients with pericarditis, the 3D sequence with Dixon fat suppression allowed for a better detection of pericardial LGE. Scan duration was significantly longer for 3D imaging (2D median 9:32 min vs. 3D median 10:46 min, p = 0.001). Conclusion: The 3D LGE sequence provides comparable LGE detection compared to 2D imaging and seems to be superior in evaluating the extent of pericardial involvement in patients suspected with pericarditis due to the robust Dixon fat suppression. Key Points: • Three-dimensional LGE imaging provides high-resolution detection of myocardial scarring. • Robust Dixon water-fat separation aids in the assessment of pericardial disease. • The 2D image navigator technique enables 100% respiratory scan efficacy and permits predictable scan times.

20 February 2022 in European Radiology
Verified
Journal Article
Open access
PDF file
MZMartin Zeilinger
Martin Zeilinger
KKKarl-Philipp Kunze
Karl-Philipp Kunze
CMCamila Munoz
Camila Munoz
RNRadhouene Neji
Radhouene Neji
MSMichaela Schmidt
Michaela Schmidt
CPClaudia Prieto
Claudia Prieto
Objectives: To investigate the efficacy of an in-line non-rigid motion-compensated reconstruction (NRC) in an image-navigated high-resolution three-dimensional late gadolinium enhancement (LGE) sequence with Dixon water–fat separation, in a clinical setting. Methods: Forty-seven consecutive patients were enrolled prospectively and examined with 1.5 T MRI. NRC reconstructions were compared to translational motion-compensated reconstructions (TC) of the same datasets in overall and different sub-category image quality scores, diagnostic confidence, contrast ratios, LGE pattern, and semiautomatic LGE quantification. Results: NRC outperformed TC in all image quality scores (p < 0.001 to 0.016; e.g., overall image quality 5/5 points vs. 4/5). Overall image quality was downgraded in only 23% of NRC datasets vs. 53% of TC datasets due to residual respiratory motion. In both reconstructions, LGE was rated as ischemic in 11 patients and non-ischemic in 10 patients, while it was absent in 26 patients. NRC delivered significantly higher LGE-to-myocardium and blood-to-myocardium contrast ratios (median 6.33 vs. 5.96, p < 0.001 and 4.88 vs. 4.66, p < 0.001, respectively). Automatically detected LGE mass was significantly lower in the NRC reconstruction (p < 0.001). Diagnostic confidence was identical in all cases, with high confidence in 89% and probable in 11% datasets for both reconstructions. No case was rated as inconclusive. Conclusions: The in-line implementation of a non-rigid motion-compensated reconstruction framework improved image quality in image-navigated free-breathing, isotropic high-resolution 3D LGE imaging with undersampled spiral-like Cartesian sampling and Dixon water–fat separation compared to translational motion correction of the same datasets. The sharper depictions of LGE may lead to more accurate measures of LGE mass. Key Points: • 3D LGE imaging provides high-resolution detection of myocardial scarring. • Non-rigid motion correction provides better image quality in cardiac MRI. • Non-rigid motion correction may lead to more accurate measures of LGE mass.

1 December 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
TSTilo Schlittenbauer
Tilo Schlittenbauer
MZMartin Zeilinger
Martin Zeilinger
ENEmeka Nkenke
Emeka Nkenke
SKSebastian Kreißel
Sebastian Kreißel
MWMatthias C. Wurm
Matthias C. Wurm
MBMichael Beck
Michael Beck

29 November 2023 in La radiologia medica
Verified
Journal Article
Open access
PDF file
MZMartin Zeilinger
Martin Zeilinger
DGDaniel Giese
Daniel Giese
MSMichaela Schmidt
Michaela Schmidt
MMMatthias Stefan May
Matthias Stefan May
RJRolf Janka
Rolf Janka
CTChristoph Treutlein
Christoph Treutlein
Objectives: To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta. Materials and methods: Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale. Results: All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07–0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08–0.94). Conclusion: The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.

7 January 2019 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
RHRebecca A. Hammon
Rebecca A. Hammon
HSHannes Seuss
Hannes Seuss
MHMatthias Hammon
Matthias Hammon
CGChristian Grillhösl
Christian Grillhösl
RHRafael Heiss
Rafael Heiss
OROliver Rompel
Oliver Rompel
Peripherally inserted central catheters (PICCs) provide secure intravenous access for the delivery of life-sustaining medications and nutrition. They are commonly used in pediatrics. Confirmation of correct central catheter tip position is crucial. Verification is usually done by a radiograph. The aim of this study is to evaluate the ability of Fractional Multiscale image Processing (FMP) to detect PICC tips on the digital chest radiographs of neonates. A total of 94 radiographs of 47 patients were included in the study. 29 patients were male, 18 were female. The mean age of all examined children was 9.2 days (range 0–99 days). In total, six readers (two radiologists, two residents in radiology, one last year medical student, one neonatologist) evaluated 94 unprocessed and catheter-enhanced radiographs using a 5-point Likert scale (1 = poor catheter tip visualization, 5 = excellent catheter tip visualization). Additionally, the two radiologists evaluated the diagnostic confidence for chest pathologies using a 5-point Likert scale (1 = poor diagnostic confidence, 5 = excellent diagnostic confidence). Radiographs were evaluated on a dedicated workstation. In all cases, the catheter-enhanced radiograph rated higher than (n = 471), or equal (n = 93) to, the unprocessed radiograph when visualizing catheter tips. 87% of the catheter-enhanced radiographs obtained a rating of 4 or higher, while only 42% of unprocessed radiographs received 4 or more points. Regarding diagnostic confidence for chest pathologies one radiologist rated two catheter-enhanced radiographs higher than the unprocessed radiographs, while all other 186 evaluations rated the catheter-enhanced radiographs equal to (n = 78) or lower than (n = 108) the unprocessed radiographs. Only 60% of the catheter-enhanced radiographs yielded a diagnostic confidence of 4 or higher, while 90% of the unprocessed images received 4 or more points. Catheter-enhanced digital chest radiographs demonstrate improved visualization of low contrast PICC tips in neonates compared to unprocessed radiographs. Furthermore, they enable detection of accompanying chest pathologies. However, definitive diagnosis of chest pathologies should be made on unprocessed radiographs.

23 October 2024 in Investigative Radiology
Verified
Journal Article
Open access
IWInes Md Willershausen
Ines Md Willershausen
SEStefania Dds Evangeliou
Stefania Dds Evangeliou
HFHans-Peter Fautz
Hans-Peter Fautz
PAPatrick Amarteifio
Patrick Amarteifio
Matthias MayMatthias May
Matthias May
MKMarkus Kopp
Markus Kopp
Objectives: This study sought to elucidate the diagnostic performance of 0.55 T magnetic resonance imaging (MRI) for pediatric dental imaging, specifically in terms of the image quality (IQ) for detecting ectopic and/or supernumerary teeth, compared with routine ultra-low-dose computed tomography (ULD-CT) of the jaw. Materials and Methods: A total of 16 pediatric patients (mean age: 12.4 ± 2.6 years, range: 9–17 years) with ectopic and/or supernumerary teeth screened from January 2023 to January 2024 were enrolled in this prospective, single-center study. All patients underwent ULD-CT as the clinical reference standard and 0.55 T MRI as the study scan on the same day. A 0.6-mm isotropic 3-dimensional T1w FLASH sequence was developed with a dedicated field of view of the upper and lower jaws. ULD-CT was performed using a new single-source computed tomography (CT) scanner equipped with a tin filter (Sn100, slice thickness: 1 mm, quality reference mAs: 24). The IQ for the tooth axis, the tooth length, the tooth root, root resorptions, cysts, the periodontal ligament space, and the mandibular canal was evaluated twice by 3 senior readers using a 5-point Likert scale (LS) (LS score of 1: insufficient, 3: reduced IQ but sufficient for clinical use, and 5: perfect) and compared between both methods. Subsequently, the results were dichotomized into nonvalid (LS score of ≤2) and valid (LS score of ≥3) for clinical use. Results: A total of 49 ectopic and/or supernumerary teeth in 16 pediatric patients were investigated using ULD-CT (CTDI: 0.43 ± 0.09 mGy) and 0.55 T MRI. The mean MRI acquisition time was 9:45 minutes. Motion artifacts were nonsignificantly different between 0.55 T MRI and ULD-CT (P = 0.126). The IQ for the tooth axis, the tooth root, root resorptions, and cysts was similar between the methods. The IQ for the periodontal ligament space and tooth length favored ULD-CT by 14% (confidence interval [CI]: 4.3%–24%) and 7.5% (CI: 1.8%–13%), respectively, whereas that for the mandibular canal favored 0.55 T MRI by −35% (CI: −54%–16%). Sufficient IQ was found especially for cystic lesions (CT: 100% sufficient, MRI: 95% sufficient), the tooth root (CT: 100%, MRI: 98%), root resorptions (CT: 94%; MRI: 85%), the tooth axis (CT: 100%; MRI: 98%), and the tooth length (CT: 99%; MRI: 91%). Conclusions: The findings indicate that 0.55 T MRI is a feasible, radiation-free technique for delineating ectopic and/or supernumerary teeth in pediatric patients. Nevertheless, to date, 0.55 T MRI has not yet been able to provide an optimal IQ for all anatomical tooth and jaw structures. In cases of advanced clinical indications that require optimal spatial resolution, high-resolution CT or cone-beam CT may still be necessary.