Matthias C. Wurm

Matthias C. Wurm

Auto-generated profile, based on publicly available information

Matthias C. Wurm

Department of Cranio- and Maxillofacial Surgery, Paracelsus Medical University Nuremberg, Breslauer Straße 201, 90471 Nuremberg, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2019 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
PDF file
KPKara K. Poon
Kara K. Poon
MWMatthias C. Wurm
Matthias C. Wurm
DEDonald Evans
Donald Evans
MEMari‐Ann Einarsrud
Mari‐Ann Einarsrud
RLRainer Lutz
Rainer Lutz
JGJulia Glaum
Julia Glaum
Total joint replacement implants are generally designed to physically mimic the biological environment to ensure compatibility with the host tissue. However, implant instability exposes patients to long recovery periods, high risk for revision surgeries, and high expenses. Introducing electrical stimulation to the implant site to accelerate healing is promising, but the cumbersome nature of wired devices is detrimental to the implant design. We propose a novel strategy to stimulate cells at the implant site by utilizing piezoelectric ceramics as electrical stimulation sources. The inherent ability of these materials to form electric surface potentials under mechanical load allows them to act as internal power sources. This characteristic is commonly exploited in non‐biomedical applications such as transducers or sensors. We investigate calcium/zirconium‐doped barium titanate (BCZT) ceramics in an in vitro environment to determine their potential as implant materials. BCZT exhibits low cytotoxicity with human osteoblast and endothelial cells as well as high piezoelectric responses. Microstructural adaptation was identified as a route for optimizing piezoelectric behavior. Our results show that BCZT is a promising system for biomedical applications. Its characteristic ability to autonomously generate electric surface potentials opens the possibility to functionalize existing bone replacement implant designs to improve implant ingrowth and long‐term stability.

1 August 2018 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
MWMatthias C. Wurm
Matthias C. Wurm
TBTessa K. Behrends
Tessa K. Behrends
WWWolfgang Wüst
Wolfgang Wüst
MWMarco Wiesmüller
Marco Wiesmüller
AWAndre Wilkerling
Andre Wilkerling
TSTilo Schlittenbauer
Tilo Schlittenbauer

1 January 2019 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
MWMatthias C. Wurm
Matthias C. Wurm
JHJulia Hagen
Julia Hagen
ENEmeka Nkenke
Emeka Nkenke
FNFriedrich Wilhelm Neukam
Friedrich Wilhelm Neukam
TSTilo Schlittenbauer
Tilo Schlittenbauer

1 December 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
TSTilo Schlittenbauer
Tilo Schlittenbauer
MZMartin Zeilinger
Martin Zeilinger
ENEmeka Nkenke
Emeka Nkenke
SKSebastian Kreißel
Sebastian Kreißel
MWMatthias C. Wurm
Matthias C. Wurm
MBMichael Beck
Michael Beck

5 March 2023 in Tomography
Verified
Journal Article
Open access
PDF file
JTJuergen Taxis
Juergen Taxis
LULena Ungerboeck
Lena Ungerboeck
MGMika Ruben Gehrking
Mika Ruben Gehrking
CMConstantin Motel
Constantin Motel
MWMatthias Wurm
Matthias Wurm
SSSteffen Spoerl
Steffen Spoerl
Orbital floor fractures represent a common fracture type of the midface and are standardly diagnosed clinically as well as radiologically using linear measurement methods. The aim of this study was to evaluate the accuracy of diagnostic measurements of isolated orbital floor fractures based on two-dimensional (2D) and three-dimensional (3D) measurement techniques. A cohort of 177 patients was retrospectively and multi-centrically evaluated after surgical treatment of an orbital floor fracture between 2010 and 2020. In addition to 2D and 3D measurements of the fracture area, further fracture-related parameters were investigated. Calculated fracture areas using the 2D measurement technique revealed an average area of 287.59 mm2, whereas the 3D measurement showed fracture areas with a significantly larger average value of 374.16 mm2 (p < 0.001). On average, the 3D measurements were 1.53-fold larger compared to the 2D measurements. This was observed in 145 patients, whereas only 32 patients showed smaller values in the 3D-based approach. However, the process duration of the 3D measurement took approximately twice as long as the 2D-based procedure. Nonetheless, 3D-based measurement of orbital floor defects provides a more accurate estimation of the fracture area than the 2D-based procedure and can be helpful in determining the indication and planning the surgical procedure.