Kris Scicluna

Dr. Kris Scicluna

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KSKris Scicluna
Kris Scicluna
CSCyril Spiteri Staines
Cyril Spiteri Staines
Reiko RauteReiko Raute
Reiko Raute

1 October 2017
Verified
Conference Paper
Open access
KSKris Scicluna
Kris Scicluna
CSC. Spiteri Staines
C. Spiteri Staines
Reiko RauteReiko Raute
Reiko Raute
This paper presents the design and implementation of a current controlled Rotor Flux Oriented PMSM for automotive steer-by-wire applications. The development of a realistic torque feedback reference is carried out by monitoring the steering torque while driving a commercial vehicle. The paper shall discuss the torque dynamics of the PMSM drive with respect to position demands replicating a driver at the handwheel.

20 October 2016
Verified
Conference Paper
Closed access
KSKris Scicluna
Kris Scicluna
CSCyril Spiteri Staines
Cyril Spiteri Staines
Reiko RauteReiko Raute
Reiko Raute
This paper shall present the design and implementation of a MATLAB/Simulink Model for the sensorless control of a PMSM in a steer-by-wire application. Simulation results for position, speed and current loops in both open-loop and closed-loop sensorless modes are shown. The sensorless method is based on the tracking of saliencies by high frequency injection.

1 October 2017
Verified
Conference Paper
Closed access
MMM. Mariano
M. Mariano
KSKris Scicluna
Kris Scicluna
JSJeremy Scerri
Jeremy Scerri
This paper presents the modelling and simulation of a low-power Brushless DC machine in a Rotor Flux Oriented mode in MATLAB/Simulink. The modelling of the machine is presented in the synchronous dq frame. Using this model suitable Proportional Integral controllers have been designed for the Rotor Flux Oriented speed and current loops. Sensorless simulation estimates obtained from a back-emf observer for both electrical angle and rotor speed are presented. The dynamic response of the model is also shown in sensorless closed-loop whereby the estimates obtained are used for control purposes. The error in the estimated position and speed during closed-loop are kept below 1.9 % and 0.1 % respectively such that the speed controlled system is stable throughout a wide range of speeds.

1 October 2017
Verified
Conference Paper
Closed access
KSKris Scicluna
Kris Scicluna
CSC. Spiteri Staines
C. Spiteri Staines
RRR. Raute
R. Raute
This paper shall present the design, simulation and implementation of a sensorless observer for three-phase permanent magnet synchronous machines which can be used for automotive steer-by-wire applications. The observer tracks steering transients enabling the sensorless speed/position estimates to be used for backup in case of encoder failure. The sensorless method is based on a high frequency injection approach which estimates speed/position from machine saliencies. The simulation/experimental test scenarios were designed so as to emulate actual steering conditions studied as part of this research project.

1 November 2018
Verified
Conference Paper
Closed access
CSClive Seguna
Clive Seguna
ABAdrian von Brockdorff
Adrian von Brockdorff
JSJeremy Scerri
Jeremy Scerri
KSKris Scicluna
Kris Scicluna
Electromyography (EMG) signals are commonly used by researchers to study kinesiology, which can then be used to control prosthetic arms, hands and limbs [1]. Additionally, EMG signals are used in the field of Bio Robotics for gesture control applications. The aim of this work is to implement a set of affordable active electrodes for the classification of finger movement via time-domain analysis. The electromyography signals are received through the Ag-AgCI electrodes, which are conductive materials used for gathering and transferring the muscle activation potential. The proposed paper focuses on presenting a new low-cost based system for the classification of human finger movement using auto-gain adjustment active electrodes. Different people will have different EMG amplitudes; therefore, it is difficult to determine the gain required prior performing further signal processing. In this work the implementation of an auto-adjustable gain amplifier was used. This circuit monitors the maximum EMG signal amplitude and adjusts the gain stage accordingly, without any user interaction. This ensures that the gain is always automatically adjusted to get the most effective performance from the data acquisition or analogue to digital converter (ADC) module since the signal will be neither too low in amplitude to cause inefficient use of the ADC resolution, not too high to cause saturation of the signal. Additionally, the instrumentation amplifier is directly interfaced near the Ag-AgCI electrodes. Through extensive experiments, our sEMG sensor outperforms a widely used commercially available product and when tested under ten different persons our low cost EMG data acquisition system achieves reproducible and repeatable results for the detection and classification of finger movements.