ANAND B

Dr. ANAND B


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2017 in IEEE/CAA Journal of Automatica Sinica
Verified
Journal Article
Open access
KJK. Jagatheesan
K. Jagatheesan
ABANAND B
ANAND B
SSSourav Samanta
Sourav Samanta
Nilanjan DeyNilanjan Dey
Nilanjan Dey
AAAmira Ashour
Amira Ashour
Valentina Emilia BalasValentina Emilia Balas
Valentina Emilia Balas
Essentially, it is significant to supply the consumer with reliable and sufficient power. Since, power quality is measured by the consistency in frequency and power flow between control areas. Thus, in a power system operation and control, Automatic Generation Control (AGC) plays a crucial role. In this paper, multi-area (Five areas: area 1, area 2, area 3, area 4 and area 5) reheat thermal power systems are considered with Proportional-Integral-Derivative (PID) controller as a supplementary controller. Each area in the investigated power system is equipped with appropriate governor unit, turbine with reheater unit, generator and speed regulator unit. The PID controller parameters are optimized by considering nature bio-inspired Firefly Algorithm (FFA). The experimental results demonstrated the comparison of the proposed system performance (FFA-PID) with optimized PID controller based Genetic Algorithm (GA) (GAPID) and Particle Swarm Optimization (PSO) technique (PSOPID) for the same investigated power system. The results proved the efficiency of employing the Integral Time Absolute Error (ITAE) cost function with one percent Step Load Perturbation (1% SLP) in area 1. The proposed system based FFA achieved the least settling time compared to using the GA or the PSO algorithms, while, it attained good results with respect to the peak overshoot/undershoot. In addition, the FFA performance is improved with the increased number of iterations which outperformed the other optimization algorithms based controller.

28 January 2023 in Technologies
Verified
Journal Article
Open access
PDF file
BDBoopathi Dhanasekaran
Boopathi Dhanasekaran
JKJagatheesan Kaliannan
Jagatheesan Kaliannan
ABANAND B
ANAND B
Nilanjan DeyNilanjan Dey
Nilanjan Dey
Joao Manuel R.S. TavaresJoao Manuel R.S. Tavares
Joao Manuel R.S. Tavares
The performance of load frequency control (LFC) for isolated multiple sources of electric power-generating units with a proportional integral derivative (PID) controller is presented. A thermal, hydro, and gas power-generating unit are integrated into the studied system. The PID controller is proposed as a subordinate controller to stabilize system performance when there is a sudden demand on the power system. The particle swarm optimization (PSO) algorithm is used to obtain optimal gain values of the proposed PID controller. Various cost functions, mainly integral time absolute error (ITAE), integral absolute error (IAE), integral squared error (ISE), and integral time squared error (ITSE) were used to optimize controller gain parameters. Furthermore, the enhancement of the PSO technique is proven by the performance comparison of conventional, differential evolution (DE) algorithm- and genetic algorithm (GA)-based PID controllers for the same system. The results show the PSO-PID controller delivers a faster settled response and the percentage improvement of the proposed technique over the conventional method is 79%, over GA is 55%, and over DE is 24% in an emergency in a power system.

28 August 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MMMohamed Ahmed Ebrahim Mohamed
Mohamed Ahmed Ebrahim Mohamed
JKJagatheesan Kaliannan
Jagatheesan Kaliannan
ABANAND B
ANAND B
This article presents frequency regulation of an interconnected three-area power system (Thermal + Wind + Hydro). Fractional Order PID (FOPID) and Proportional-Integral-Derivative (PID) controllers are applied as subsidiary regulators to control the electrical power interconnected system at the time of sudden load variation. To accomplish this study, Genetic Algorithm (GA), Grey Wolf Optimizer (GWO), Sine Cosine Inspired Algorithm (SCIA) and Atom Search Inspired Algorithm (ASIA) are implemented to optimize the secondary regulators' gains (PID and FOPID) by considering various cost functions such as Integral Absolute Error (IAE), Integral Time Absolute Error (ITAE), Integral Square Error (ISE), and Integral Time Square Error (ITSE). Performance analysis in this work is conducted using various cost functions based on GA, GWO, SCIA and ASIA. The comparative analysis of the attained results reveals that GWO-PID and ASIA–PID settle at (83.83 s) and (30.31 s), respectively and ASIA-FOPID at (25.12 s). The controllers based on ITSE as a cost function outperform the comptrollers with other cost functions (ISE, IAE and ITAE). In addition, the ISE-based GA–PID and SCIA–PID settle at (113.92 s) and (35.1 s), respectively and SCIA-FOPID at (24.78 s). The ISE-based regulators yield improved response equated to other cost functions (ITSE, IAE and ITAE) optimized controllers. The robustness test also is carried out to validate the effectiveness of the proposed optimization techniques by changing the system parameters within ± 25% and ± 50% from their nominal values as well as changing the load pattern.

30 May 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
DBDhanasekaran Boopathi
Dhanasekaran Boopathi
JKJagatheesan Kaliannan
Jagatheesan Kaliannan
ABANAND B
ANAND B
SSSourav Samanta
Sourav Samanta
Nilanjan DeyNilanjan Dey
Nilanjan Dey
The primary goal of this article is to design and implement a secondary controller with which to control the system frequency in a networked microgrid system. The proposed power system comprises of Renewable energy sources (RESs), energy-storing units (ESUs), and synchronous generator. RESs include photovoltaic (PV) and wind turbine generator (WTG) units. The ESU is composed of a flywheel and a battery. Because renewable energy sources are not constant in nature, their values fluctuate from time to time, causing an effect on system frequency and power flow variation in the tie line. The nonlinear output from the RESs is balanced with the support of ESUs. In order to address this situation, a proportional integral derivative (PID) controller based on the Mayfly algorithm (MA) is proposed and built. Comparing the responses of controllers based on the genetic algorithm (GA), differential evolution (DE), and particle swarm optimization (PSO) technique-optimized to demonstrate the superiority of the MA-tuned controller.. The results of the validation comparisons reveal that the implemented MA-PID controller delivers and is capable of regulating system frequency under various load demand changes and renewable energy sources. A robustness analysis test was also performed in order to determine the effectiveness of the suggested optimization technique (1%, 2%, 5%, and 10%) step load perturbation (SLP) with ±25% and ±50% variation from the nominal governor and reheater time constant).


1 April 2021 in International Journal of Applied Evolutionary Computation
Verified
Journal Article
Closed access
PDF file
BDBoopathi Dhanasekaran
Boopathi Dhanasekaran
SSS. Saravanan
S. Saravanan
JKJagatheesan Kaliannan
Jagatheesan Kaliannan
ABANAND B
ANAND B
This paper proposes the particle swarm optimization (PSO) technique-based proportional integral derivative (PID) controller suggested for frequency regulation of a micro grid (MG) system. MG system integrates with thermal power generating units, renewable energy sources (RES) like photovoltaic (PV), wind energy generators (WTG), and Energy storage systems (ESS) such as fuel cell (FC) and battery energy storage system (BESS). Indentifying the supremacy of proposed technique-based controller and supremacy is examined with three objective functions (integral absolute error [IAE], integral time absolute error [ITAE], and integral squared error [ISE]). The results of the system are compared with conventional PID controller results. From the comparison, it is clearly evident that PSO-PID controller gives better performance over conventional methods in terms of various time domain specific parameters such as settling time, peak overshoot, and undershoot. In both methods, ITAE objective function used controller produce more effective response in MG under sudden load demand situation.