The use of fuzzy logic controllers in refrigeration and air conditioning systems, RACs, has as main objective to maintain certain thermal and comfort conditions. In this sense, fuzzy controllers have proven to be a viable option for use in RACs due to their ease of implementation and their ability to integrate with other control systems and control improvements, as well as their ability to achieve potential energy savings. In this document, we present a review of the application of fuzzy controls in RACs based on vapor compression technology. Application information is discussed for each type of controller, according to its application in chillers, air conditioning systems, refrigerators, and heat pumps. In addition, this review provides detailed information on controller design, focusing on the potential to achieve energy savings; this design discusses input and output variables, number and type of membership functions, and inference rules. The future perspectives on the use of fuzzy control systems applied to RACs are shown as well. In other words, the information in this document is intended to serve as a guide for the creation of controller designs to be applied to RACs.
Maintaining adequate temperatures for preserving food in a domestic refrigerator is a task that is affected by several factors, including the daily use of the appliance. In this sense, this work presents the development of a novel control system based on fuzzy logic that considers usage habits such as the amount of food entering the refrigerator and the frequency of opening doors. Thus, the control comprises input variables corresponding to the internal temperatures of both compartments, the thermal load entered, and the refrigerator door-opening signal. By simulating the usage habits of a refrigerator with a variable-speed compressor, the control performance was evaluated. The results showed that implementing fuzzy control using usage habits was robust enough to maintain adequate thermal conditions within the compartments and a lower thermal fluctuation concerning the reference control of the refrigerator (factory control). In terms of energy, the fuzzy control resulted in an energy saving of 3.20% with the refrigerator empty (without thermal load) compared to the reference control. On the other hand, the individual integration of the thermal load in the fuzzy control resulted in 2.08% energy savings and 5.45% for the integration of the thermal load compared to the reference control. Finally, considering the combination of usage habits, the fuzzy control presented a higher energy consumption than the reference control, around 9.7%. In this case, the fuzzy control maintained more favorable thermal conditions in both compartments, whereas the reference control presented a warmer thermal condition in the freezer.
In the field of domestic refrigeration, it is important to look for methods that can be used to simulate, and, thus, improve the thermal behavior of the fresh food compartment. In this sense, this study proposes some methods to model the thermal behavior of this compartment when the shelves’ positions are changed. Temperature measurements at specific locations in this compartment were obtained. Several shelf position combinations were performed to use three 2D interpolation methods in order to simulate the temperature mean and the temperature variance. The methods used were: Lagrange’s interpolation, cubic spline interpolation and bilinear interpolation. Two validation points were chosen to verify the proposed methods. By comparing the experimental results with the computer simulations, it was possible to conclude that the method of Lagrange’s interpolation provided values that were not close to the real measured values. On the other hand, it was observed that the method of bilinear interpolation offered the best results, estimating values which were very close to the actual experimental measurements. These interpolation methods were used to build color thermal graphs that can be used to find some of the most appropriate shelf position combinations in this type of refrigerator. By inspection of these thermal graphs, it can be seen that the lowest average temperature was obtained when one shelf was located at 24.5 cm while the second shelf was located at 29.5 cm measured from the top of the compartment. In the same way, it can be seen that the minimum temperature variance was obtained when only one shelf was inside the compartment and this shelf was located at 29.5 cm.
Miniature vapor compression refrigeration systems are gaining increasing relevance in cutting-edge applications such as drone docking station cooling, electric vehicle battery thermal management, portable medical and diagnostic devices, compact beverage dispensers, field-mounted telecom cabinet cooling, as well as the already established fields of electronics and personal cooling. These systems offer a promising pathway to localized and mobile cooling solutions. When coupled with the implementation of alternative low-GWP refrigerants that match or even enhance system performance, the result is a more efficient, environmentally responsible, and potentially sustainable refrigeration technology. Therefore, this study experimentally evaluates the performance of R515B as a low-GWP drop-in replacement for R134a in a miniature vapor compression refrigeration system. Key parameters were analyzed to determine the most suitable operating conditions, resulting in a capillary length of 1.25 m, refrigerant charge of 110 g, compressor speed of 4500 rpm, and high condenser fan speed, under which R515B achieved a COP of 5.16 and a cooling capacity of 252.20 W, representing improvements of 38% and 6.5%, respectively, compared to R134a. These results confirm the viability of R515B as an efficient, environmentally friendly alternative for miniature small-scale vapor compression systems.
14 February 2020 in Journal of Thermal Science and Engineering Applications
A transient study of the cooling process inside a cabinet is presented in this work. Computational fluid dynamics (CFD) is used to obtain the transient temperature of the air inside a small cabinet. Three cooling levels, named Case 1, Case 2, and Case 3, were studied under different lapses of time and operational conditions. The temperature of the evaporator plate and the temperature of the room change with time through the implementation of user-defined functions (UDFs). The buoyancy effects that occur inside the cabinet (natural convection) were modeled using the approximation of all the properties fitted to temperature polynomials (PFTP). The transient temperature of the air inside the cabinet was obtained, until the second ON/OFF stage is reached, for the three cases studied. The prediction of the transient temperature of the air inside the small cabinet was validated with experimental data. The average relative errors of the transient temperatures of the air inside the cabinet were 0.49%, 0.19%, and 0.13% for Case 1, Case 2, and Case 3, respectively. The behavior of the temperature and velocity distributions of the air inside the cabinet for the ON and OFF stages is obtained. Finally, a better range of the temperature for the preservation of food, medicines, and biological matter is obtained with an increase in the thickness of the insulation material. An increment of 14.9% of the removed energy was obtained inside the cabinet with 12 cm of the insulation material, and this increment is related to the case with no insulation material. The results of this work could help in improving the design and performance of the cabinets in further works.