Several techniques for estimating power losses in insulated-gate bipolar transistors (IGBTs), diodes and MOSFETs are known. Most of the approaches in the literature deal with PWM switching technique. In this paper presents a feasible loss model to estimate IGBT losses in a switching operation. The loss model is coupled to RC (Foster) Network using the Thermal Impedance. This paper investigates the power losses in IGBT's and associated Diodes as a function of the circuit and the temperature variation during operation. A full presentation of the electro-thermal model has been developed and simulated.
1 January 2016 in Progress In Electromagnetics Research M
This paper diagnoses the effect of the AC current densities induced by the electromagnetic interferences between high voltage power line and buried power line on the cathodic protection performances of the X70 steel in the simulated soil. First, the induced voltage onto the pipeline was calculated for various power line configurations, separation distances between transmission line and pipeline and parallelism lengths. The induced AC current density was computed function to the induced voltage, soil resistivity, and holiday diameter. Then, the electrochemical characters of the X70 steel, at various AC current densities, are measured using the potentiodynamic method. The electrochemical parameters obtained by the electrochemical tests are used as boundary conditions in the cathodic protection simulation model. The results indicate that, under influence of AC current densities, the X70 steel is more susceptible to corrosion, and the cathodic protection is unable to maintain the protection potential.
1 September 2017 in IET Science, Measurement & Technology
The inductive coupling between high‐voltage power lines (HVPL) and buried pipelines has been an important research subject over the last decades. This coupling may result in alternating current (AC) on pipelines that may pose a serious threat to the pipelines due to corrosive effects and the cathodic protection (CP) performance. A method to investigate the effects of the induced AC density on the corrosion and the CP performances of the X70 steel buried pipeline due to the inductive interference caused by HVPL is proposed in this study. The method is based on the corrosion parameters of the X70 steel pipeline obtained by electrochemical measurements such as Tafel slopes, corrosion current densities, and corrosion potentials. These parameters were used as boundary conditions in the elaborated CP model. The results showed that, firstly, the induced AC density affects the electrochemical characteristic of the X70 steel and accelerates the corrosion of the pipeline. On the other hand, the impressed current cathodic protection is incapable of maintaining the CP potential level. However, some technical solutions were proposed to prevent the pipelines from AC corrosion and maintain the CP potential to an acceptable level.
In this paper, a model based on the finite element analysis has been developed for healthy and eccentric PMSM. The proposed model is analyzed by time stepping Finite element method. The electromagnetic field distribution, air-gap magnetic flux density and the leakage inductances under healthy and eccentric rotor have been calculated. Meanwhile, the MCSA of the healthy and faulty PMSM is inspected under various static eccentricity levels.