Bridge scour is the number one cause of failure in bridges located over waterways. Scour leads to rapid losses in foundation stiffness and can cause sudden collapse. Previous research on bridge health monitoring has used changes in natural frequency to identify damage in bridge beams. The possibility of using a similar approach to identifying scour is investigated in this paper. To assess if this approach is feasible, it is necessary to establish how scour affects the natural frequency of a bridge, and if it is possible to measure changes in frequency using the bridge dynamic response to a passing vehicle. To address these questions, a novel vehicle–bridge–soil interaction (VBSI) model was developed. By carrying out a modal study in this model, it is shown that for a wide range of possible soil states, there is a clear reduction in the natural frequency of the first mode of the bridge with scour. Moreover, it is shown that the response signals on the bridge from vehicular loading are sufficient to...
6 September 2017 in Journal of Civil Structural Health Monitoring
Detecting scour by analysing bridge vibrations is receiving an increasing amount of attention in the literature. Others have considered changes in natural frequency to indicate the presence of scour damage; however, little work has been reported on identifying the location of a scour hole based on vibration measurements. In this paper, a numerical study is carried out using a bespoke vehicle–bridge–soil dynamic interaction model to examine how the first six vibration modes (Eigen frequencies) of a typical integral bridge are affected by scour at different locations. It is found that depending on the location of the scour hole, some modes are much more affected than others in terms of frequency changes. In fact, a clear pattern emerges as to which modes are affected by which scour location. Using this knowledge, the location of a scour hole can potentially be detected on a real bridge. However, recognising that it is not possible to undertake an eigenvalue analysis on an actual bridge, an analysis is performed by collecting acceleration signals from various points on the structure. The bridge is loaded by a realistic vehicle model, incorporating vehicle–bridge interaction effects, which leads to the generation of discrete acceleration signals at various ‘sensor’ locations on the bridge. In this paper, it is found that it is possible to detect the location of a scour hole using a relatively small number of ‘sensors’. However, to achieve this, careful signal processing is necessary and advice on a number of pertinent issues is provided.
3 April 2024 in Journal of Civil Structural Health Monitoring
Numerous studies have investigated the long-term monitoring of natural frequencies, primarily focusing on medium–large highway bridges, using expensive monitoring systems with a large array of sensors. However, this paper addresses the less explored issue of monitoring a footbridge, examining four critical aspects: (i) sensing system, (ii) frequency extraction method, (iii) data modelling techniques, and (iv) damage detection. The paper proposes a low-cost all-in-one sensor/logger unit instead of a conventional sensing system to address the first issue. For the second issue, many studies use natural frequency data extracted from measured acceleration for data modelling, the paper highlights the impact of the input parameters used in the automated frequency extraction process, which affects the number and quality of frequency data points extracted and subsequently influences the data models that can be created. After that, the paper proposes a modified PCA model optimised for computational efficiency, designed explicitly for sparse data from a low-cost monitoring system, and suitable for future on-board computation. It also explores the capabilities and limitations of a data model developed using a limited data set. The paper demonstrates these aspects using data collected from a 108 m cable-stayed footbridge over several months. Finally, the detection of damage is achieved by employing the one-class SVM machine learning technique, which utilises the outcomes obtained from data modelling. In summary, this paper addresses the challenges associated with the long-term monitoring of a footbridge, including selecting a suitable sensing system, automated frequency extraction, data modelling techniques, and damage detection. The proposed solutions offer a cost-effective and efficient approach to monitoring footbridges while considering the challenges of sparse data sets.
Structural Health Monitoring (SHM) is a technique that involves gathering information to ensure that a structure is safe and behaving as expected. Within SHM, vibration-based monitoring is generally seen as one of the more cost-effective types of monitoring. However, vibration-based monitoring has mostly been undertaken on long-span bridges using data collected with a dense network of sensors. Historically, the logistical difficulty of collecting data on short- and medium-span bridges has meant that the usefulness of vibration-based methods on these bridges is largely unknown. Therefore, this study proposes Minimal Information Data-modelling (MID). MID is an approach that utilises low-cost, easily implementable sensors that are potentially feasible for operators to purchase and operate across a network. This approach will be investigated to determine whether MID is a feasible approach for monitoring short- and medium- span bridges. The results from MID were assessed to determine whether they could detect a suitably small shift in frequency, which is indicative of damage. It was determined that the data models could reliably detect frequency shifts as low as 0.01 Hz. This magnitude of frequency shift is similar to the level of frequency shift reported for a range of bridge damage cases found by others and validated with FE models. The accuracy achieved by the data models indicates that MID could potentially be used as a damage detection method. The cost of the equipment used to collect the data was approximately £370, demonstrating that it is feasible to use MID to monitor bridges across an entire network.
15 April 2014 in Structure and Infrastructure Engineering
Previous research on damage detection based on the response of a structure to a moving load has reported decay in accuracy with increasing load speed. Using a 3D vehicle–bridge interaction model, this paper shows that the area under the filtered acceleration response of the bridge increases with increasing damage, even at highway load speeds. Once a datum reading is established, the area under subsequent readings can be monitored and compared with the baseline reading, if an increase is observed it may indicate the presence of damage. The sensitivity of the proposed approach to road roughness and noise is tested in several damage scenarios. The possibility of identifying damage in the bridge by analysing the acceleration response of the vehicle traversing it is also investigated. While vehicle acceleration is shown to be more sensitive to road roughness and noise and therefore less reliable than direct bridge measurements, damage is successfully identified in favourable scenarios.
Various approaches have been proposed for bridge structural health monitoring. One of the earliest approaches proposed was tracking a bridge’s natural frequency over time to look for abnormal shifts in frequency that might indicate a change in stiffness. However, bridge frequencies change naturally as the structure’s temperature changes. Data models can be used to overcome this problem by predicting normal changes to a structure’s natural frequency and comparing it to the historical normal behaviour of the bridge and, therefore, identifying abnormal behaviour. Most of the proposed data modelling work has been from long-span bridges where you generally have large datasets to work with. A more limited body of research has been conducted where there is a sparse amount of data, but even this has only been demonstrated on single bridges. Therefore, the novelty of this work is that it expands on previous work using sparse instrumentation across a network of bridges. The data collected from four in-operation bridges were used to validate data models and test the capabilities of the data models across a range of bridge types/sizes. The MID approach was found to be able to detect an average frequency shift of 0.021 Hz across all of the data models. The significance of this demonstration across different bridge types is the practical utility of these data models to be used across entire bridge networks, enabling accurate and informed decision making in bridge maintenance and management.