Nan Peng

Dr. Nan Peng

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2019 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Rui LiangRui Liang
Rui Liang
Nan PengNan Peng
Nan Peng
LZLutian Zhou
Lutian Zhou
XMXiangzhen Meng
Xiangzhen Meng
Yihua HuYihua Hu
Yihua Hu
Xue XUEXue XUE
Xue XUE
Faults may be generated in power networks as a result of bad weather, human activities or some other factors. The complex structure of power network adds to the difficulty of fault location (FL). This paper presents a novel FL scheme by utilizing the information of the time differences of arrival (TDOAs) of modal traveling waves (MTWs) asynchronously sampled in the network. First, the fault area is determined by searching the minimum TDOA of MTWs. Then, by applying the fictitious fault point method in the fault area, the minimum accumulated difference is used to detect the fault line. Finally, the accurate FL is estimated by solving the objective function of the absolute distance between the FL and multiple FL candidates. Various simulations are carried out in IEEE 30-bus system. The calculation results demonstrate that the method is not affected by fault impedance, inception angle, location and noises to a certain extent.

13 July 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Nan PengNan Peng
Nan Peng
Rui LiangRui Liang
Rui Liang
GWGuanhua Wang
Guanhua Wang
PSPeng Sun
Peng Sun
CCChunyu Chen
Chunyu Chen
THTianyu Hou
Tianyu Hou
The feeders in distribution networks can be generally classified into two types: homogenous and hybrid feeders. Hybrid feeders consist of non-homogeneous line segments. In this paper, a fault location scheme is proposed for distribution grids with both homogenous and hybrid feeders using the edge computing. The standard transient amplitude ratio arrays of the hybrid feeders are first constructed and stored at the edge nodes. Then, an accurate fault location model is trained by the radial basis function neural network and stored in the substation server. To achieve this goal, the transients are first sampled at the measurement nodes and transmitted to the edge nodes nearby. The amplitudes are then extracted to determine the faulty branch. For a hybrid feeder, the actual amplitude ratio array is compared with the standard one to identify the faulty line segment. Finally, the amplitude ratio of the two transient components with different frequencies at one terminal of the faulty section is computed and transmitted to the server. Based on the model of a distribution network built by PSCAD/EMTDC, extensive fault simulations are studied. The results demonstrate the effectiveness of the scheme.

28 July 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
PZPeng Zhang
Peng Zhang
LKLingchang Kong
Lingchang Kong
Rui LiangRui Liang
Rui Liang
BXBingyin Xu
Bingyin Xu
Nan PengNan Peng
Nan Peng
With significant technological advancements in power grids, three-core cables are widely employed for their safety and other benefits. In general, three-core cables in medium-voltage distribution systems are laid underground during operation. As a result, the harsh working environment and complex fault conditions can bring massive challenges to fault location issues. To address the problem, the distinctive cable features are extensively considered in this article, including relatively larger capacitance, cable shield effects, and shield bonding methods. Initially, an equivalent cable model is developed to analyze the relationship between shield-grounding wire currents and the fault point. A single-phase grounding fault location method is then formulated based on the ratio of shield-grounding wire currents at both terminals. In power systems computer aided design/electro magnetic transient in DC system (PSCAD/EMTDC), a range of fault scenarios are simulated to verify the proposed method. In comparison to conventional similar approaches, the proposed method exhibits higher accuracy and robustness to fault resistance and diverse fault conditions. Finally, the effectiveness of the proposed method is validated on a real 10 kV distribution network experimental platform under several fault scenarios.

23 February 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
PZPeng Zhang
Peng Zhang
MJMohan Jin
Mohan Jin
Rui LiangRui Liang
Rui Liang
ZTZehua Tang
Zehua Tang
MHMeng Hou
Meng Hou
JLJuan Li
Juan Li
Faults in underground cables are hard to be detected directly from external features such as sound and light due to the harsh operating environment. Moreover, the rising penetration of distributed generations further complicates the characteristics of cable faults. Facing the challenges, this article first aims to reveal cable fault features via analyzing the generation mechanism of the cable grounding wire current (GWC). The impact of photovoltaic on GWC is then discussed, and the essential differences between faulty and healthy cables are also studied. Finally, considering both the structure of distribution network and an optimal deployment of measurement points, a novel fault cable segment identification method based on the amplitude and polarity of the starting terminal GWC steady-state variation is proposed. Simulations based on a real low-resistance grounded distribution network are performed in diverse fault scenarios and show a near 100% accuracy for all cases. In addition, the proposed method demonstrated a time complexity of O (896), showing a significant reduction in calculation time compared to common methods. These findings suggest that the proposed method is highly reliable and efficient for identifying faulty cable segments in active distribution networks.

24 November 2017 in Energies
Verified
Journal Article
Open access
PDF file
Rui LiangRui Liang
Rui Liang
ZYZhi Yang
Zhi Yang
Nan PengNan Peng
Nan Peng
CLChenglei Liu
Chenglei Liu
FZFiruz Zare
Firuz Zare
This paper proposes a grounding fault location method in transmission lines based on time difference of arrival (TDOA) of ground-mode and aerial-mode traveling waves (TWs). The frequency-dependent characteristics of transmission lines cause different frequencies to have different attenuations and phase lags of different frequency components in traveling waves, which leads to the change of TWs velocities with different propagation distances. Due to these different propagation paths, the wave velocity variations of ground-mode should be considered as a main variable while the velocity of aerial-mode can be seen as a constant factor. A quadratic function that can illustrate the tendency of variation of ground-mode wave velocity is proposed by considering the relation between the wave velocity and fault distance. The least squares method is used to solve the quadratic function of different lines. Combining the quadratic formula and the incident TWs of each mode detected at both terminals of the line, a novel fault location method is proposed. First, according to the maximum and minimum ground-mode velocities, a fault scope can be acquired. Then, more accurate fault scopes and ground-mode velocities can be obtained by iteration computation. Finally, an accurate fault position is acquired when the fault scope is sufficiently small. PSCAD/EMTDC software is used to conduct fault simulations in order to verify the feasibility and accuracy of the method.

26 April 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Nan PengNan Peng
Nan Peng
XLXinyu Liu
Xinyu Liu
Rui LiangRui Liang
Rui Liang
ZTZehua Tang
Zehua Tang
XRXiaofeng Ren
Xiaofeng Ren
GLGuoxin Li
Guoxin Li
Due to the complex structures and fault conditions, accurate fault sensing of the underground distribution cables is a difficult task. The distribution automation system (DAS) and fault indicator system (FIS) are only applicable to the severe faults. In addition, the current DAS and FIS are all based on the centralized data processing system (CDS), increasing the communication pressure and data processing time of the main station. Considering the advantages of edge computing, this paper investigates using the grounding line currents to sense the fault in distribution cable networks. First, an edge computing based fault sensing system (ECS) is designed. The equivalent time-domain distribution cable models considering multi-conductor mutual couplings are then established in both normal and fault cases. The time-domain features of the cable grounding line currents prior to and after the fault are analyzed to create the fault detection criterion. Combining the network topology, locations of the measurement units (MUs), and direction factor of the ground line current, a space matrix based algorithm is created to achieve fault cable section location at edge. Finally, a distribution cable network is created by PSCAD/EMTDC. Various simulations are conducted to validate the effectiveness and robustness of the algorithm.