Yakov Gataulin

Mr. Yakov Gataulin


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Fluid Dynamics
Verified
Journal Article
Open access
PDF file
VMV. M. Molochnikov
V. M. Molochnikov
NDN. S. Dushin
N. S. Dushin
NPN. D. Pashkova
N. D. Pashkova
YGYakov Gataulin
Yakov Gataulin
ESE. M. Smirnov
E. M. Smirnov
AYAndrey Yukhnev
Andrey Yukhnev
The results of experimental studies and numerical simulation of the flow structure in the separation region downstream of an asymmetric narrowing of smooth canal that simulates 70% one-sided stenosis of the artery are presented. The Reynolds number was equal to 1800. The instantaneous flow velocity vector fields were measured using the SIV technique. The numerical solution was obtained by the large eddy simulation (LES) method. Setting the disturbances in numerical simulation close to the experimental conditions made it possible to obtain a satisfactory agreement between the calculated and experimental velocity fields and the components of the Reynolds stress tensor. The data on formation of the local flow turbulence region behind the constriction and subsequent downstream flow relaminarization are obtained. It is shown that a pair of secondary eddies localized within the region of flow separation is formed near the throat of the constriction.

1 December 2015 in St. Petersburg Polytechnical University Journal: Physics and Mathematics
Verified
Journal Article
Open access
YGYakov Gataulin
Yakov Gataulin
DZDmitriy K. Zaitsev
Dmitriy K. Zaitsev
ESEvgueni M. Smirnov
Evgueni M. Smirnov
EFEkaterina A. Fedorova
Ekaterina A. Fedorova
AYAndrey Yukhnev
Andrey Yukhnev
Investigation of weakly swirling flow in a model of a blood vessel with asymmetrical stenosis has been performed using both experimental flow measurement techniques (ultrasound Doppler) and computational fluid dynamics methods. A special attention is paid to getting data for the length of the reverse-flow zone occurring past the stenosis. It has been established that the laminar steady-state flow model is acceptable for numerical analysis of flow past the given-geometry stenosis at Reynolds number values less than 300. At higher values of this parameter, application of the semi-empirical k-ω SST turbulence model is preferable. It has been shown that flow swirl can lead to an increase of the reverse-flow zone

1 November 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
YGYakov Gataulin
Yakov Gataulin
AYA D Yukhnev
A D Yukhnev
SSSergei Smirnov
Sergei Smirnov
DRD A Rosukhovskiy
D A Rosukhovskiy
The paper presents the results of the numerical study of the flow in a symmetric model of the venous valve with different leaflet elasticity. The focus is on the analysis of the velocity field and the stagnant region. The stagnant region behind the valve is of great practical interest for phlebologists in terms of the potential for the formation of blood clots. The constructed simplified model of the venous valve has given a good qualitative agreement with the clinical ultrasound data on the position of the valve leaflet and the stagnant zone behind the valve.

4 March 2024 in Fluids
Verified
Journal Article
Open access
PDF file
AYAndrey Yukhnev
Andrey Yukhnev
LTLudmila Tikhomolova
Ludmila Tikhomolova
YGYakov Gataulin
Yakov Gataulin
AMAlexandra Marinova
Alexandra Marinova
ESEvgueni Smirnov
Evgueni Smirnov
GKGennady Khubulava
Gennady Khubulava
This paper presents the experience of using the V Flow high-frame-rate ultrasound vector imaging method to study the pulsatile velocity fields in the area of the proximal anastomosis for femoral popliteal bypass surgery in vitro and in vivo. A representative (average) anastomosis model and the experimental setup designed for in vitro studies covering forward and reverse flow phases throughout the cycle are described. The results of the measurements are presented for areas with a relatively uniform velocity distribution and for areas with pronounced spatial inhomogeneities due to the jet or recirculating nature of the flow. The results of ultrasonic studies of the velocity field of the three-dimensional pulsatile flow in vitro and in vivo are compared with the data of numerical simulations carried out for the average and personalized models based on the Navier–Stokes equations. Acceptable consistency between the results of experimental and numerical studies is demonstrated.

1 November 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
YGYakov Gataulin
Yakov Gataulin
AYA D Yukhnev
A D Yukhnev
DRD A Rosukhovskiy
D A Rosukhovskiy
In this study, a fully coupled fluid–structure interaction computational model for a pulsatile flow in the venous valve was developed. An arbitrary Lagrangian–Eulerian formulation is used in the coupled model, considering two domains, specifically the blood flow and the valve leaflets. The effect of the gap width between the valve leaflets (venous valve incompetence) on the valve reverse flow (reflux) has been investigated.

1 January 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
AKAnna A. Kotmakova
Anna A. Kotmakova
YGYakov Gataulin
Yakov Gataulin
AYAndrey Yukhnev
Andrey Yukhnev
The present contribution is aimed at numerical and experimental study of inlet swirling flow in a model of the carotid artery. Flow visualization is performed both with the ultrasound color Doppler imaging mode and with CFD data postprocessing of swirling flows in a carotid artery model. Special attention is paid to obtaining data for the secondary motion in the internal carotid artery. Principal errors of the measurement technique developed are estimated using the results of flow calculations.