We report on a new method for the measurement of the level dependence of the AC-DC difference of current shunts. The method is based on the use of a binary inductive current divider. A method to compare two AC shunts at common ground is described. Measurement results on two 1-A AC shunts, which consist of different numbers of resistors, indicate that the level dependence between 0.5 and 1 A is less than 2 ¿A/A with an uncertainty of less than 7 ¿A/A from 1 to 100 kHz.
5 August 2025 in IEEE Transactions on Instrumentation and Measurement
Degradation state assessment and remaining useful life (RUL) prediction are crucial for formulating maintenance strategies under variable operating conditions. Current cross-condition RUL prediction methods primarily depend on extensive labeled source and target domain data for domain alignment. However, in practice, the amount of labeled data is limited, and these data inevitably exhibit low-quality attributes due to anomalies or missing values, leading to an increase in the distributional differences of degraded data under variable working conditions. This situation makes the RUL prediction methods difficult to obtain satisfactory domain alignment and generalization performance. To address this challenge, a new self-supervised dual-path meta alignment network is proposed for RUL prediction under limited data and unknown operating conditions. In the dual-path structure, the model utilizes Bayesian inference to learn degradation features and treat them as hidden variables, thus enhancing the model’s ability to quantify the uncertainty of sharing knowledge across different tasks. Then, the distribution of potential representations of the dual paths is aligned using a domain space alignment technique to improve the feature information for domain adaptation. In addition, the shared knowledge and task-specific information in the dual paths are integrated into a lightweight self-attention network, which allows for exploring long-term dependencies in related tasks and capturing richer domain information. Finally, extensive experiments on engine and bearing degraded data are conducted to verify the superior performance of the proposed model.
For calibration of analyzer of harmonic voltage, current and power under non-sinusoidal condition at fundamental in industrial frequency, a harmonic power standard has been built at NIM, in which non-integer-period sampling is applied. Its setup, algorithm, and whole uncertainty are reported.
27 February 2023 in IEEE Transactions on Instrumentation and Measurement
A system for ac-dc voltage transfer at ultra-low frequencies is established with dual-heater thermal voltage converter (DHTVC) in this paper. The system is based on the premise that the thermoelectric potential of TVC is square related with the input voltages. The output thermoelectric potential is constant when two orthogonal and equal-amplitude sinusoidal signals are input to the DHTVC. How to evaluate and compensate the key parameters that affect the stability of output thermoelectric potential is discussed in detail. In this paper a verification method is also proposed to prove the accuracy of the ac-dc transfer results at low frequencies based on quantum voltage technology. The high-precision digitizer PXI-5922 is introduced as the transfer standard. The ac-dc difference of sampling error is calibrated using ac-dc voltage transfer with DHTVC as the reference standard at low frequencies down to 0.1 Hz. The dc and ultra-low frequency errors are also calibrated by programmable Josephson voltage standard (PJVS). The uncertainties of calibration results from two different methods are evaluated respectively. The calibration results from ac-dc voltage transfer with DHTVC and PJVS show good agreement and inconsistency is less than 5 μV/V at frequency ranges from 10 Hz down to 0.1 Hz.
31 March 2026 in IEEE Transactions on Geoscience and Remote Sensing
Object counting in remote sensing images remains highly challenging due to the dense distribution and high similarity of targets. Existing Transformer-based counting models have achieved remarkable success, but they often suffer from the attention map response convergence issue, where attention maps across different regions become overly similar. To address this limitation, we propose Graph-Modulated Attention and Centrality-Enhanced Network (GACENet), a novel architecture that rethinks attention mechanisms through the lens of graph-structured diversity enhancement. Our framework introduces three groundbreaking components: the Anti-Similarity Attention Graph (ASAG) module, the Centrality-Aware Feature Enhancement (CAFE) mechanism, and a composite loss function. First, the ASAG module dynamically learns a graph that explicitly models semantic dissimilarity between regions, forcing attention heads to focus on complementary features rather than converging to redundant patterns. Second, the CAFE module is designed to mitigate weak responses to key target regions caused by attention homogeneity. It is a topological prior-driven module that identifies and amplifies critical nodes via graph centrality analysis, ensuring robust representation of key targets even under extreme density conditions. Finally, a composite loss function that combines a structural loss and a diversity loss, which encourages response variation across spatial locations. Extensive experiments on multiple remote sensing counting datasets demonstrate that GACENet significantly outperforms other state-of-the-art remote counting methods in terms of MAE and MSE.
This paper presents a method to evaluate smart meter working status by analyzing multi-data of smart meters. It is a multi-source data fusion technique based on D-S evidence theory. In the proposed algorithm, entropy method used to compute the weight of indicators, then we use convex function to assign the probabilities of evidence. Finally, we obtain the evaluation working status by D-S evidence theory. The results of simulation indicate the applicability of the approach in real time scenarios.