Ray G. DeCorby

Prof. Ray G. DeCorby


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MBMohammad Bitarafan
Mohammad Bitarafan
RDRay G. DeCorby
Ray G. DeCorby
For applications in sensing and cavity-based quantum computing and metrology, open-access Fabry-Perot cavities—with an air or vacuum gap between a pair of high reflectance mirrors—offer important advantages compared to other types of microcavities. For example, they are inherently tunable using MEMS-based actuation strategies, and they enable atomic emitters or target analytes to be located at high field regions of the optical mode. Integration of curved-mirror Fabry-Perot cavities on chips containing electronic, optoelectronic, and optomechanical elements is a topic of emerging importance. Micro-fabrication techniques can be used to create mirrors with small radius-of-curvature, which is a prerequisite for cavities to support stable, small-volume modes. We review recent progress towards chip-based implementation of such cavities, and highlight their potential to address applications in sensing and cavity quantum electrodynamics.

2 September 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
RDRay G. DeCorby
Ray G. DeCorby
NPN. Ponnampalam
N. Ponnampalam
EEE. Epp
E. Epp
TAT. Allen
T. Allen
JMJ.N. McMullin
J.N. McMullin
We describe a micro-spectrometer that exploits out-of-plane radiation at mode cutoff in a tapered leaky waveguide clad by omnidirectional Bragg reflectors. The device can be viewed as a side-coupled, tapered Fabry-Perot cavity. An effective-index transfer-matrix model reveals that optimal resolution is dependent on the reduction or mitigation of back-reflection and standing waves leading up to the cutoff point. We address this by insertion of low numerical aperture optics between the taper and the detector, and demonstrate an experimental resolution as small as ~1 nm and operating bandwidth >100 nm in the 1550 nm range, from a tapered waveguide with footprint ~50 μm x 500 μm. The device combines the small size of a Fabry-Perot instrument with the detector array compatibility and fixed optics of a grating-based instrument.

25 August 2022 in Optics Express
Verified
Journal Article
Open access
GHGraham Hornig
Graham Hornig
KSKyle G. Scheuer
Kyle G. Scheuer
EDE. B. Dew
E. B. Dew
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
RDRay G. DeCorby
Ray G. DeCorby
We describe the use of monolithic, buckled-dome cavities as ultrasound sensors. Patterned delamination within a compressively stressed thin film stack produces high-finesse plano-concave optical resonators with sealed and empty cavity regions. The buckled mirror also functions as a flexible membrane, highly responsive to changes in external pressure. Owing to their efficient opto-acousto-mechanical coupling, thermal-displacement-noise limited sensitivity is achieved at low optical interrogation powers and for modest optical (Q ∼ 103) and mechanical (Q ∼ 102) quality factors. We predict and verify broadband (up to ∼ 5 MHz), air-coupled ultrasound detection with noise-equivalent pressure (NEP) as low as ∼ 30-100 µPa/Hz1/2. This corresponds to an ultrasonic force sensitivity ∼ 2 × 10−13 N/Hz1/2 and enables the detection of MHz-range signals propagated over distances as large as ∼ 20 cm in air. In water, thermal-noise-limited sensitivity is demonstrated over a wide frequency range (up to ∼ 30 MHz), with NEP as low as ∼ 100-800 µPa/Hz1/2. These cavities exhibit a nearly omnidirectional response, while being ∼ 3-4 orders of magnitude more sensitive than piezoelectric devices of similar size. Easily realized as large arrays and naturally suited to direct coupling by free-space beams or optical fibers, they offer significant practical advantages over competing optical devices, and thus could be of interest for several emerging applications in medical and industrial ultrasound imaging.

25 May 2015 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
MBM. H. Bitarafan
M. H. Bitarafan
HRH. Ramp
H. Ramp
TAT. W. Allen
T. W. Allen
CPC. Potts
C. Potts
XRX. Rojas
X. Rojas
RDRay G. DeCorby
Ray G. DeCorby
We report on the thermomechanical and thermal tuning properties of curved-mirror Fabry–Perot resonators, fabricated by the guided assembly of circular delamination buckles within a multilayer a-Si/SiO2 stack. Analytical models for temperature dependence, effective spring constants, and mechanical mode frequencies are described and shown to be in good agreement with experimental results. The cavities exhibit mode volumes as small as ∼10λ3, reflectance-limited finesse ∼3×103, and mechanical resonance frequencies in the MHz range. Monolithic cavity arrays of this type might be of interest for applications in sensing, cavity quantum electrodynamics, and optomechanics.

15 November 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
EEE. Epp
E. Epp
NPN. Ponnampalam
N. Ponnampalam
WNW. Newman
W. Newman
BDB. Drobot
B. Drobot
JMJ. N. McMullin
J. N. McMullin
RDRay G. DeCorby
Ray G. DeCorby
We describe integrated air-core waveguides with Bragg reflector claddings, fabricated by controlled delamination and buckling of sputtered Si/SiO2 multilayers. Thin film deposition parameters were tailored to produce a desired amount of compressive stress, and a patterned, embedded fluorocarbon layer was used to define regions of reduced adhesion. Self-assembled air channels formed either spontaneously or upon heating-induced decomposition of the patterned film. Preliminary optical experiments confirmed that light is confined to the air channels by a photonic band-gap guidance mechanism, with loss ~5 dB/cm in the 1550 nm wavelength region. The waveguides employ standard silicon processes and have potential applications in MEMS and lab-on-chip systems.

14 September 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
TAT. W. Allen
T. W. Allen
JSJ. Silverstone
J. Silverstone
NPN. Ponnampalam
N. Ponnampalam
TOT. Olsen
T. Olsen
AMA. Meldrum
A. Meldrum
RDRay G. DeCorby
Ray G. DeCorby
Arrays of half-symmetric Fabry-Perot micro-cavities were fabricated by controlled formation of circular delamination buckles within a-Si/SiO2 multilayers. Cavity height scales approximately linearly with diameter, in reasonable agreement with predictions based on elastic buckling theory. The measured finesse (F > 103) and quality factors (Q > 104 in the 1550 nm range) are close to reflectance limited predictions, indicating that the cavities have low roughness and few defects. Degenerate Hermite-Gaussian and Laguerre-Gaussian modes were observed, suggesting a high degree of cylindrical symmetry. Given their silicon-based fabrication, these cavities hold promise as building blocks for integrated optical sensing systems.