25 August 2022 in Optics Express
We describe the use of monolithic, buckled-dome cavities as ultrasound sensors. Patterned delamination within a compressively stressed thin film stack produces high-finesse plano-concave optical resonators with sealed and empty cavity regions. The buckled mirror also functions as a flexible membrane, highly responsive to changes in external pressure. Owing to their efficient opto-acousto-mechanical coupling, thermal-displacement-noise limited sensitivity is achieved at low optical interrogation powers and for modest optical (Q ∼ 103) and mechanical (Q ∼ 102) quality factors. We predict and verify broadband (up to ∼ 5 MHz), air-coupled ultrasound detection with noise-equivalent pressure (NEP) as low as ∼ 30-100 µPa/Hz1/2. This corresponds to an ultrasonic force sensitivity ∼ 2 × 10−13 N/Hz1/2 and enables the detection of MHz-range signals propagated over distances as large as ∼ 20 cm in air. In water, thermal-noise-limited sensitivity is demonstrated over a wide frequency range (up to ∼ 30 MHz), with NEP as low as ∼ 100-800 µPa/Hz1/2. These cavities exhibit a nearly omnidirectional response, while being ∼ 3-4 orders of magnitude more sensitive than piezoelectric devices of similar size. Easily realized as large arrays and naturally suited to direct coupling by free-space beams or optical fibers, they offer significant practical advantages over competing optical devices, and thus could be of interest for several emerging applications in medical and industrial ultrasound imaging.
2 June 2022 in Microsystems & Nanoengineering
AIAfshin Kashani Ilkhechi
It has long been hypothesized that capacitive micromachined ultrasound transducers (CMUTs) could potentially outperform piezoelectric technologies. However, challenges with dielectric charging, operational hysteresis, and transmit sensitivity have stood as obstacles to these performance outcomes. In this paper, we introduce key architectural features to enable high-reliability CMUTs with enhanced performance. Typically, a CMUT element in an array is designed with an ensemble of smaller membranes oscillating together to transmit or detect ultrasound waves. However, this approach can lead to unreliable behavior and suboptimal transmit performance if these smaller membranes oscillate out of phase or collapse at different voltages. In this work, we designed CMUT array elements composed of a single long rectangular membrane, with the aim of improving the output pressure and electromechanical efficiency. We compare the performance of three different modifications of this architecture: traditional contiguous dielectric, isolated isolation post (IIP), and insulated electrode-post (EP) CMUTs. EPs were designed to improve performance while also imparting robustness to charging and minimization of hysteresis. To fabricate these devices, a wafer-bonding process was developed with near-100% bonding yield. EP CMUT elements achieved electromechanical efficiency values as high as 0.95, higher than values reported with either piezoelectric transducers or previous CMUT architectures. Moreover, all investigated CMUT architectures exhibited transmit efficiency 2–3 times greater than published CMUT or piezoelectric transducer elements in the 1.5–2.0 MHz range. The EP and IIP CMUTs demonstrated considerable charging robustness, demonstrating minimal charging over 500,000 collapse-snap-back actuation cycles while also mitigating hysteresis. Our proposed approach offers significant promise for future ultrasonic applications.
19 March 2021 in Optics Letters
Transparent ultrasound transducers could enable many novel applications involving both ultrasonics and optics. Recently, we reported transparent capacitive micromachined ultrasound transducers (CMUTs) and demonstrated through-illumination photoacoustic imaging. This work presents the feasibility of transparent CMUTs for combined ultrasound imaging and through-array white-light imaging with a miniature camera placed behind the array. Transparent CMUT devices are fabricated with an adhesive wafer bonding technique and provide high transparency up to 90% in visible wavelengths. Fabricated linear arrays have a central operating frequency of 9 MHz with 128 active elements. Realtime plane-wave imaging is performed for ultrasound imaging, and lateral and axial resolutions of, respectively, 234 and 338 µm are achieved. Transparent CMUT has demonstrated a high transmit sensitivity of 1.4 kPa/V per channel with a 100 VDC bias voltage. The signal-to-noise ratio for a beamformed image of wire targets is determined to be 28.4 dB. To the best of our knowledge, this is the first report of combined realtime optical and ultrasonic imaging with transparent arrays. This technology may enable one to visually see what is being scanned and scan what one sees without co-registration errors. Future applications could include multi-modality probes for interventional and surgical procedures.
26 January 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Capacitive micromachined ultrasound transducers (CMUTs) have been investigated for over 25 years due to their promise for mass manufacturing and electronic co-integration. Previously, CMUTs were fabricated with many small membranes comprising a single transducer element. This, however, resulted in sub-optimal electromechanical efficiency and transmit performance, such that resulting devices were not necessarily competitive with piezoelectric transducers. Moreover, many previous CMUT devices were subject to dielectric charging and operational hysteresis that limited long-term reliability. Recently we demonstrated a CMUT architecture using a single long rectangular membrane per transducer element and novel electrode post structures. This architecture not only offers long-term reliability, but also provides performance advantages over previously published CMUT and piezoelectric arrays. The purpose of this paper is to highlight these performance advantages and provide details of the fabrication process, including the best practices to avoid common pitfalls. The objective is to provide sufficient detail to inspire a new generation of microfabricated transducers which could lead to performance gains of future ultrasound systems.
20 May 2025 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
Capacitive micromachined ultrasound transducers (CMUTs) are typically designed with many small membranes per linear array element. However, these membranes can operate out of phase or collapse at different voltages, leading to suboptimal transmit performance and unreliable operation. To avoid these problems, we recently proposed a CMUT architecture with a single large rectangular membrane per element and novel insulated electrode post structures. These single-membrane CMUTs outperformed comparable piezoelectric transducers by almost 3-fold in terms of output pressure and demonstrated electromechanical efficiency values as high as 0.95. In this paper, we present an analytical model which can be used to simulate and optimize single-membrane rectangular CMUTs with or without post structures. Our approach relies on a polynomial deflection model, which was used to derive lumped element model parameters. Using this method, we developed expressions to model both electrostatic and pre-collapse small-signal dynamic CMUT behavior. This modeling framework was incorporated into a MATLAB program. We validated our approach using finite element method (FEM) simulations and experimental results in both air and immersion media. Model predictions for collapse voltage and operating frequency are within 4% of FEM results in both air and immersion. However, the runtime of our MATLAB program was 6 orders of magnitude faster than the corresponding FEM simulations. Compared with experiment, collapse voltage predictions were within 8%, and operating frequency predictions were within 5% in air and 18% in soybean oil. Our results indicate that that rectangular CMUTs may be optimized much further, potentially enabling even greater improvements over piezoelectric transducers.