Yoshiaki Narusue

Dr. Yoshiaki Narusue


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Soft Robotics
Verified
Journal Article
Closed access
CCColm Mc Caffrey
Colm Mc Caffrey
TUTakuya Umedachi
Takuya Umedachi
WJWeiwei Jiang
Weiwei Jiang
TSTakuya Sasatani
Takuya Sasatani
YNYoshiaki Narusue
Yoshiaki Narusue
YKYoshihiro Kawahara
Yoshihiro Kawahara
Wireless power transfer (WPT) has the significant potential for soft-bodied continuum robots to extend the operational time limitlessly and reduce weight. However, rigid power receiver coils, widely used in WPT, hinder the continuum deformation of the robot, and as a result, the function realization using the continuum deformation (e.g., locomotion) is impaired. Therefore, this article introduces that a soft-bodied continuum robot can be designed by using thin film receiver coils and an inductively coupled wireless powering solution without sacrificing the continuum deformation and locomotion ability. A system is described for powering and controlling a soft robotic caterpillar consisting of nothing more than its continuum structure, actuators, and thin/flexible power receiving coils.

19 October 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
BDBojian Du
Bojian Du
YNYoshiaki Narusue
Yoshiaki Narusue
YFYoko Furusawa
Yoko Furusawa
NNNozomu Nishihara
Nozomu Nishihara
KIKentaro Indo
Kentaro Indo
MIMakoto Iida
Makoto Iida
Condition monitoring systems are commonly employed for incipient fault detection of wind turbines (WTs) to reduce downtime and increase availability. Data from supervisory control and data acquisition (SCADA) systems offer a potential monitoring solution. Multi-turbine approaches, which merge variables recorded from different WTs on the same wind farm, have been developed to improve fault detection performance by reducing the influence of variations in environmental conditions. However, in complex terrain, environmental conditions vary among WTs. Moreover, manual control (e.g., maintenance and curtailment) can also raise false alarms in some WTs. Here, the false alarm characteristics of a wind farm in complex terrain are investigated. A clustering-based multi-turbine fault detection approach is proposed, consisting of three steps: WT clustering, single-turbine modeling, and fault indicator calculation. First, k-medoids clustering with dependent multivariate dynamic time warping is applied for WT clustering. Then, an autoregressive neural network is used to construct a single-turbine model. Finally, residuals between median values of the model output of all WTs in the same cluster and the target WT are used to calculate the anomaly level. Evaluation results for real large-scale SCADA data confirm that the proposed approach raises fewer false alarms without degrading detection performance.

6 October 2022 in IEEE Communications Letters
Verified
Journal Article
Closed access
KMKentaro Matsuura
Kentaro Matsuura
KSKoeru Shin
Koeru Shin
DKDaisuke Kobuchi
Daisuke Kobuchi
YNYoshiaki Narusue
Yoshiaki Narusue
HMHiroyuki Morikawa
Hiroyuki Morikawa
This letter analyzes the optimal transmission period to maximize the time-averaged received power using a distributed microwave power transfer (DMPT) system. DMPT requires periodic phase and frequency synchronization. The received power is maximized immediately after synchronization because the received signals from the transmitters are coherent. However, the received power gradually degrades owing to the phase drift caused by the frequency offset of the phase-locked loop (PLL) on the transmitters. Therefore, if the power transmission period is considerably long, the time-averaged received power decreases. To design the synchronization interval, we formulated the expected value of the time-averaged received power. The expected value assists in selecting PLL elements and estimating the received power before hardware implementation of the transmitters, thus enabling the rapid design of DMPT systems.

3 March 2023 in IEEE Access
Verified
Journal Article
Open access
KMKentaro Matsuura
Kentaro Matsuura
DKDaisuke Kobuchi
Daisuke Kobuchi
YNYoshiaki Narusue
Yoshiaki Narusue
HMHiroyuki Morikawa
Hiroyuki Morikawa
Compensating for deviations in the resonant frequency is crucial in magnetic resonance coupling wireless power transfer (WPT) systems. Thus, this study proposes a communication-less receiver-side resonant frequency-tuning scheme that compensates for the reactance in the receiver without communicating with the transmitter. The proposed scheme comprises an inductor-capacitor-capacitor compensation topology at the transmitter and a half-bridge circuit at the receiver, whose operating phase is set to be orthogonal to the receiver current. Resonant frequency tuning can be achieved by adjusting the DC voltage applied to the half-bridge circuit to maximize the power received at the load. The reactance compensation ability of the proposed scheme is analyzed through experiments on a 200 kHz WPT system. When the secondary capacitance deviated from −20% to +20%, the efficiency degradation was maintained within 6.7% with the proposed scheme, whereas the efficiency degraded by up to 33.3% without compensation.

11 December 2020 in IEEE Access
Verified
Journal Article
Open access
TSTakuya Sasatani
Takuya Sasatani
YNYoshiaki Narusue
Yoshiaki Narusue
YKYoshihiro Kawahara
Yoshihiro Kawahara
Deploying 2-D arrays of multiple transmitters is a promising approach for extending wireless power transfer (WPT) to wide surfaces. However, these arrays involve “null zones”, where the transfer efficiency drops significantly. Although this problem can be hypothetically addressed by employing a receiver array and dynamically selecting the appropriate transmitter/receiver pair, designing receiver arrays that achieve high efficiency throughout the surface remains a challenging task. In this study, we propose a genetic algorithm (GA)-based approach to designing receiver arrays free of “null zones”. The main objective is enhancing worst-case scenarios, which in contrast to improving best-case scenarios, reveals significant complexities due to the need for considering numerous possible placements. We overcome this problem by establishing a design flow that leverages the simulated transfer efficiency at numerous positions throughout the surface. Our approach increased the simulated transfer efficiency at the worst position from 3.8% to 42.6%, and we confirmed these results through measurements at the extracted points.

14 February 2022 in IEEE Magnetics Letters
Verified
Journal Article
Closed access
DKDaisuke Kobuchi
Daisuke Kobuchi
KMKentaro Matsuura
Kentaro Matsuura
YNYoshiaki Narusue
Yoshiaki Narusue
HMHiroyuki Morikawa
Hiroyuki Morikawa
This letter presents a method to cancel magnetic field leakage while maintaining high power transfer efficiency (PTE) in multiple-input multiple-output wireless power transfer systems. To achieve low leakage and high PTE, the problem of PTE maximization under the cancellation condition of the magnetic field leakage is solved, which is a maximization problem of affinely constrained Rayleigh quotients. Subsequently, the optimal amplitudes and phases of the input voltages at the transmitter array and the optimal load impedances at the receivers are shown. This method can further reduce the magnetic field leakage by up to 31 dB compared with the PTE maximization method, while having a PTE drop within 5.5%.