Haoran Chen

Haoran Chen

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Wireless Communications and Mobile Computing
Verified
Journal Article
Open access
PDF file
HCHaoran Chen
Haoran Chen
XLXin Lin
Xin Lin
GLGuanhua Li
Guanhua Li
JXJianyuan Xu
Jianyuan Xu
HLHui Li
Hui Li
SWShuai Wang
Shuai Wang
Among the distribution network faults, single‐phase grounding faults have the greatest probability. The faults are often accompanied by arcs in the grounding point soil. This type of fault current has a small amplitude and seldom can obtain field record data. A soil arc grounding fault is tested on a realistic‐distribution‐network‐experimental‐platform (RDNEP), and it is concluded that the soil‐arc‐grounding‐fault (SAGF) has three main characteristics: hysteresis, nonlinearity, and asymmetry. By comparing with the characteristics of common arc models, it is pointed out that common arc models cannot accurately fit the characteristics of SAGF. This paper proposes and establishes a double exponential function arc model. Through the comparison of simulation waveforms with experimental data, it is verified that the numerical simulation method proposed in this paper can simulate the development process of SAGF more accurately. Furthermore, the equivalence of RDNEP is verified on the real distribution network system (RDNS). On this basis, analyzed the arc characteristic changes of different SAGF development cycles. Finally, by studying the applicability of the proposed model in simulating ground faults in grass and gravel roads, it is verified that the model proposed in this paper has a strong generalization capability. The research has laid a theoretical foundation for a detection algorithm that is based on the characteristics of SAGF.

24 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
SLShen Lin
Shen Lin
HCHaoran Chen
Haoran Chen
KXKai Xu
Kai Xu
JXJianyuan Xu
Jianyuan Xu
The fault detection time identified by relying on the over-voltage criterion of zero-sequence voltage often lags behind the actual occurrence time of ground faults, which may cause fault protection methods based on transient quantity principles to miss fault characteristics and lose their protection capability. To accurately estimate the time of occurrence of a single-phase-to-ground fault, this paper proposes a two-step dimensionality reduction algorithm for estimating the time of occurrence of a single-phase-to-ground fault in a distribution network. This algorithm constructs a filter based on Empirical Mode Decomposition (EMD) to establish a high-dimensional feature dataset based on the zero-sequence current of all feeders. After Principal Component Analysis and Hilbert Mapping Algorithm, the high-dimensional data are reduced to two dimensions to construct a two-dimensional feature dataset. The density-based clustering method is used to adaptively divide the data into two categories, fault data and non-fault data, so as to estimate the time of occurrence of the fault. The paper designs 11 sets of experiments including 7 common high-resistance grounding mediums to verify the accuracy of the fault time recognition of this algorithm. The accuracy of this algorithm is within 7.3 ms and it exhibits better detection performance compared to the threshold detection method.