Jianyuan Xu

Jianyuan Xu

Auto-generated profile, based on publicly available information

Jianyuan Xu

School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
CTChi Tian
Chi Tian
JXJianyuan Xu
Jianyuan Xu
SLShen Lin
Shen Lin
GYGaole Yu
Gaole Yu
WCWeidong Chen
Weidong Chen
Grid-forming (GFM) energy storage can be utilized as a backup power source for the power grid to ensure the security of the power grid. GFM energy storage can also enhance the strength of the power grid and improve its stability. However, the GFM energy storage inherits the characteristics of the synchronous generator. Low-frequency oscillations may occur in GFM energy storage, which affect the stable operation of the power system. This paper proposed an additional damping control strategy for GFM energy storage to address the low-frequency oscillation. Firstly, this paper builds the state-space small-signal mathematical model of the GFM energy storage grid-connected system to analyze the participation factors of the low-frequency oscillation mode and clarify the key control parameters affecting the GFM energy storage grid-connected system the low-frequency oscillation. Then, this paper proposed an additional damping control strategy to increase the damping ratio of the low-frequency oscillation mode and improve the stability of the GFM energy storage grid-connected system. Finally, semi-physical experiments verified the effectiveness of the proposed additional damping control strategy.

24 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
SLShen Lin
Shen Lin
HCHaoran Chen
Haoran Chen
KXKai Xu
Kai Xu
JXJianyuan Xu
Jianyuan Xu
The fault detection time identified by relying on the over-voltage criterion of zero-sequence voltage often lags behind the actual occurrence time of ground faults, which may cause fault protection methods based on transient quantity principles to miss fault characteristics and lose their protection capability. To accurately estimate the time of occurrence of a single-phase-to-ground fault, this paper proposes a two-step dimensionality reduction algorithm for estimating the time of occurrence of a single-phase-to-ground fault in a distribution network. This algorithm constructs a filter based on Empirical Mode Decomposition (EMD) to establish a high-dimensional feature dataset based on the zero-sequence current of all feeders. After Principal Component Analysis and Hilbert Mapping Algorithm, the high-dimensional data are reduced to two dimensions to construct a two-dimensional feature dataset. The density-based clustering method is used to adaptively divide the data into two categories, fault data and non-fault data, so as to estimate the time of occurrence of the fault. The paper designs 11 sets of experiments including 7 common high-resistance grounding mediums to verify the accuracy of the fault time recognition of this algorithm. The accuracy of this algorithm is within 7.3 ms and it exhibits better detection performance compared to the threshold detection method.

7 December 2023 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
EBEnming Bai
Enming Bai
JXJianyuan Xu
Jianyuan Xu

4 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
JWJunbo Wang
Junbo Wang
LLLijuan Liao
Lijuan Liao
YXYalong Xia
Yalong Xia
JXJianyuan Xu
Jianyuan Xu
SLShen Lin
Shen Lin
ZGZhenxin Geng
Zhenxin Geng
The SF6/N2 gas mixture is a key eco-friendly alternative to SF6 in power equipment. However, its insulation and decomposition behaviors under realistic conditions of varying pressure and electric field non-uniformity remain insufficiently studied. This study establishes an experimental platform to systematically investigate the power–frequency breakdown and decomposition characteristics of a 3:7 SF6/N2 mixture. Breakdown tests and critical field strength calculations were conducted under different pressures and electric field uniformities, followed by gas composition analysis. Results demonstrate that the proposed critical breakdown field strength method effectively predicts the mixture’s breakdown voltage. Furthermore, a range of decomposition products, including NF3, SOF2, CO2, and C2F6, were identified, whose concentrations generally decreased with rising pressure. These findings provide valuable experimental data and a predictive tool for optimizing the insulation design and condition monitoring of SF6/N2 gas-insulated equipment.

29 September 2026 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
DGDongyu Guo
Dongyu Guo
XLXIAOLONG LI
XIAOLONG LI
JXJianyuan Xu
Jianyuan Xu
ZGZhenxin Geng
Zhenxin Geng
Metallic particles within gas-insulated switchgear (GIS) can distort electric fields, leading to gas discharge. Their adsorption onto insulator surface is particularly hazardous, as it can cause flashover and seriously compromise insulation safety. In this study, a transparent conductive scaled GIS busbar is used combined with an object detection model to investigate the motion and adsorption characteristics of linear metallic particle in dry air. Results show that, compared to SF 6 gas, the metallic particle in dry air exhibits higher velocity and a wider range of movement. However, it shows a lower probability of engaging in firefly motion and adsorbing onto insulator surfaces. Under positive polarity, the primary pattern is reciprocating movement. In contrast, under negative polarity, the particle exhibits prolonged swaying firefly motion on the conductor surface. Furthermore, increasing voltage enhances velocity and reduces the likelihood of firefly motion. Additionally, increasing the particle radius decreases firefly motion probability, whereas increasing length leads to the opposite result. Finally, the lifting position has no significant impact. This study supports suppressing metallic particle contamination and optimizing insulation design in dry air DC-GIS.

3 September 2023 in Electronics
Verified
Journal Article
Open access
PDF file
QZQingsong Zhao
Qingsong Zhao
GMGuixi Miao
Guixi Miao
HDHong Dai
Hong Dai
CJCheng Jing
Cheng Jing
JXJianyuan Xu
Jianyuan Xu
HMHui Ma
Hui Ma
In this paper, based on the pseudo-totem pole (PTP) circuit, a family of five-level PTP dual boost converters (PDBC) is proposed. A dual boost converter has some unique advantages, such as having no risk of bridge arm shoot-through and no problems related to switch body diode reverse recovery; thus, it has a good potential for applications. First, the derivation process, working principle, modulation and strategy of the topology are analyzed. Further, the number of power devices, switch voltages and current stress of the proposed topology is analyzed. Finally, a representative five-level PDBC experimental prototype is designed with AC input 220 V/50 Hz, DC output 400 V/1 kW, and peak efficiency of 98.27%. The experimental results show that the five-level PDBC proposed in this paper has higher efficiency and the correctness of its topology is verified.