Huan LIU

Dr. Huan LIU

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2024 in Building and Environment
Verified
Journal Article
Closed access
LLLumeng Liu
Lumeng Liu
JXJinghui Xin
Jinghui Xin
ZLZhi Liu
Zhi Liu
WZWenmao Zeng
Wenmao Zeng
QLQisheng Li
Qisheng Li
HLHuan LIU
Huan LIU

15 May 2023 in Building and Environment
Verified
Journal Article
Closed access
MLMeng Liu
Meng Liu
BSBingyang Shen
Bingyang Shen
ZGZifeng Gan
Zifeng Gan
JLJingying Liu
Jingying Liu
QLQisheng Li
Qisheng Li
HLHuan LIU
Huan LIU

18 August 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
LLLumeng Liu
Lumeng Liu
NWNing Wan
Ning Wan
WZWenmao Zeng
Wenmao Zeng
JSJiachen Shi
Jiachen Shi
MLMeng Liu
Meng Liu
HLHuan LIU
Huan LIU
Removing indoor CO2 as a pollutant via solid sorbents is a promising solution to maintaining acceptable indoor air quality while minimizing the energy consumption of ventilation. Compared to fixed-bed and fluidized-bed configurations, which require at least two beds to allow for continuous operation, a rotary adsorber is more compact and suitable to be integrated into the ventilation systems of buildings. In the present study, a regenerative rotary adsorber based on temperature swing adsorption was modeled to investigate continuous CO2 capture in an indoor environment. The governing equations of heat and mass transfer processes associated with the capture were established and coded in ANSYS Fluent software. The spatiotemporal variations of CO2 concentration and temperature in gas and solid phases within the rotary adsorber were obtained. The key findings are: (1) adjusting the speed mainly affects circumferential concentration and temperature distribution, but has little impact on axial concentration and temperature; (2) Increasing desorption inlet flow rate has little impact on adsorption outlet concentration, but significantly decreases desorption outlet concentration; (3) Raising desorption inlet temperature can increase both adsorption and desorption outlet average concentrations; (4) Reducing the volume proportion of the desorption sector will slightly increase adsorption outlet concentration and slightly decrease desorption outlet concentration, but barely affects average adsorption and desorption outlet temperatures.

22 June 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
WZWenmao Zeng
Wenmao Zeng
HLHuan LIU
Huan LIU
SHShanshan Hou
Shanshan Hou
XQXiangwei Qiu
Xiangwei Qiu
XCXinchang Chen
Xinchang Chen
LLLumeng Liu
Lumeng Liu
Exposure to natural environments has a range of health benefits, including enhancing psychological restoration and cognitive development. While there are various explanations on the causes for the benefits of the natural exposure, such as less air pollution and noise, more physical activity, stronger social interactions, or even more diverse microbial community, etc., this study has zeroed in on the air quality of the natural environment. In addition to low-level pollution, what makes the natural air superior remains unclear. To this end, we conducted a series of psychological evaluation and cognitive tests on a couple of subjects in a national forest park in southwest China. Based on the results, we built an artificial chamber where selected air parameters can be independently manipulated and carried out similar tests in the chamber. We came to the following conclusion. (1) Exposure to real natural environment demonstrated tangible benefits for cognitive performances and mental states and the benefits can be obtained to some extent in the artificial environment by creating air qualities similar to the air in the natural environment. (2) Scents in natural environments may be one of the key beneficial factors. (3) Adopting proper cognitive test is critical for distinguishing the differences made by the natural exposure. Working memory showed marked responses to the natural exposure.

3 February 2025 in Building and Environment
Verified
Journal Article
Closed access
LLLumeng Liu
Lumeng Liu
DHDi Huang
Di Huang
SWShuwan Wang
Shuwan Wang
QLQisheng Li
Qisheng Li
TFTing Fu
Ting Fu
HLHuan LIU
Huan LIU

21 December 2023 in Indoor and Built Environment
Verified
Journal Article
Closed access
BSBingyang Shen
Bingyang Shen
MLMeng Liu
Meng Liu
LLLumeng Liu
Lumeng Liu
HLHuan LIU
Huan LIU
Bacteria in built environments are profoundly affected by indoor thermal conditions. In China, continuous and intermittent heating modes give rise to distinct thermal environments in winter. However, the quantitative relationships between bacterial concentration and thermal conditions in the context of heating modes remain unclear. To this end, we recorded the temperature and relative humidity (RH) in 15 intermittently and 15 continuously heated residences in 27 cities across China and obtained the bacterial concentrations via the quantitative polymerase chain reaction technology. For the intermittently heated residences whose temperatures were lower than 18°C, the bacterial concentration negatively correlated with RH while the correlation was positive for those with T > 18°C. For the continuously heated residences, a quadratic correlation was found between temperature and the bacterial concentration which was highest at 23°C. For lower bacterial risk, we suggest that (1) RH in the intermittent heating region should be in the range of 40%–60% and (2) temperature in the continuous heating region should not exceed 22°C. The bacteria-adjusted thermal zones for intermittent and continuous heating are 66% and 77% of the original thermal comfort zone, respectively. Our study provides insights into the set-points of indoor thermal environments based on the microbial perspective.