Aleksandra Dragoljub Čairović

Dr. Aleksandra Dragoljub Čairović

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
AGAleksandra Špadijer Gostović
Aleksandra Špadijer Gostović
ARAleksandar Racić
Aleksandar Racić
ATAleksandar Todorović
Aleksandar Todorović
KRKatarina Radović
Katarina Radović
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
IJIvana Vlatković Jakovljević
Ivana Vlatković Jakovljević
The aim of this article was to evaluate properties of new polymer material, based on PEEK, for FPDs in patients with parafunctions. Methods: Prospective clinical study involved patients with diagnosed signs and symptoms of parafunctions, restored with 100 units, PEEK based FPDs, veneered with composite material. During one year observation period the following parameters were evaluated: color changes, periodontal indices, treatment success using FDI criteria, occlusal parameters, patient-reported outcome measures (OHIP-49) and occurrence of complications. Results: Spectrophotometry revealed that 63% of bridges experienced changes for L*, a*, b* color parameters, but it was not clinically significant for patients. Periodontal indices (PI, GI, BOP) revealed statistically significant higher values around restorations. According to FDI criteria, therapy was considered successful and 86.7% of FPDs were acceptable. Computerized occlusal analysis demonstrated no significant difference in the number of occlusal contacts and the intensity of relative forces between restoration and control side. Results of OHIP-49 questionnaire showed improved patient’s quality of life. Complications appeared in a limited number of cases. Conclusion: PEEK based FPDs could be indicated for successful prosthodontic rehabilitation in patients with parafunctional activities, but further material improvements and long-term clinical trials should be conducted to analyze performance of this material in challenging cases, for patients with CMD and in implant therapy.

1 January 2019 in Archives of Biological Sciences
Verified
Journal Article
Open access
PDF file
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
DSDragan M. Stanimirović
Dragan M. Stanimirović
TKTamara Krajnovic
Tamara Krajnovic
BDBiljana Dojcinovic
Biljana Dojcinovic
VMVesna Maksimovic
Vesna Maksimovic
ICIvana Lj. Cvijović-Alagić
Ivana Lj. Cvijović-Alagić
The biological quality and chemical composition of alloys used in dental practice change during heat treatment. Often the residues of the previous cast are not disposed of but are reused and recycled until consumed. Thus, manufactured dental restorations have modified biological quality and chemical composition, and compromised biocompatibility. The aim of this study was to investigate the influence of repeated casting on the cytotoxicity of the silver-palladium (Ag-Pd) alloy. Our results showed that repeated casting of the Ag-Pd dental alloy affected its biocompatibility by promoting toxicity against transformed fibroblasts in a contact-independent manner. A strong decrease in cell proliferation, induction of senescence and massive cell death were observed in cultures exposed only to a medium previously incubated with dental alloy samples. The obtained data indicated that toxicity mediated by the accumulation of the Ag, Pd, Cu and Zn cations released from the Ag-Pd material was enhanced by recasting. The induction of cell senescence and subsequent apoptotic and necrotic death were accompanied by amplified intracellular production of reactive oxygen and nitrogen species, suggesting their involvement in the cell destruction process. Therefore, compromised biocompatibility after recasting with the Ag-Pd alloy can be the cause of serious local cell destruction, as observed in clinical practice.

20 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MPMirjana Perić
Mirjana Perić
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
AGAleksandra Špadijer Gostović
Aleksandra Špadijer Gostović
DSDragan Milorad Stanimirović
Dragan Milorad Stanimirović
MKMarina Kostić
Marina Kostić
VPVladimir Pavlovic
Vladimir Pavlovic
Objective: The purpose of this study was to evaluate the surface texture and biofilm adhesion of veneered or CAD/CAM milled zirconia (partially stabilized with yttrium) after professional oral hygiene procedures. The samples (4 × 4 mm, thickness 2 mm; n = 72) were separated from zirconia blanks (3Y-TZP-LA). One group was veenered with ceramics, and the other group of samples was CAD/CAM milled. Each group had two subgroups: polished and glazed. The samples were subjected to simulated strokes of professional brushing using abrasive paste and ultrasonic scaling. The parameters of surface micromorphology and receptivity to biofilm were calculated before and after simulating the given methods of the professional maintenance of oral hygiene. Scanning electron microscopy (SEM) was used to evaluate zirconia surface properties. Microbial (bacterial/fungal) species (Staphylococcus aureus, Streptococcus sanguinis and Candida albicans) were used and cultured on respective sterilized zirconia surfaces. Colony-forming unit (CFU) counts were used to quantify the amount of biofilm formation on zirconia samples surfaces. Results: The SEM analysis showed the greatest change in surface microtopography after the use of ultrasonic scaling on glazed zirconia samples. Less formation of colonies on the surfaces of CAD/CAM milled zirconia restorations was observed. Conclusion: Routine methods of oral hygiene professional maintenance can damage the surfaces of glazed zirconia restorations.

15 May 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
MPMirjana Perić
Mirjana Perić
NČNevena Čairović
Nevena Čairović
LŽLuka Župac
Luka Župac
VMVesna Maksimovic
Vesna Maksimovic
DSDragan Milorad Stanimirović
Dragan Milorad Stanimirović
Purpose: This study provides a comparative evaluation of surface changes in BioHPP materials under routine professional hygiene procedures, which is recommended by dentists, twice a year. BioHPP is a polyetheretherketone polymer used in prosthetic dentistry as a frame material. The aim was to investigate whether routine dental cleaning procedures such as ultrasonic scaling and brushing affect the surface proprieties of prosthetic BioHPP restorations. This study was conducted to evaluate the surface properties of different restorations based on BioHPP (veneered with composite resin and polished) after brushing and ultrasonic scaling exposure. Materials and Methods: The BioHPP specimens were divided into three groups. The first group (marked BioHPP) served as a baseline reference for assessing the effect of different surface processing approaches, and no further treatment was applied. The specimens in the second group (BioHPP-P) were polished, while the specimens in the third group (BioHPP-C) were veneered with composite resin. Group BioHPP-P and BioHPP-C of samples was divided into three subgroups: 0—no treatment, 1—exposed to tooth brushing, 2—exposed to ultrasonic scaling. Untreated samples (subgroup 0) served as controls for evaluating treatment-related changes within groups 2 and 3. The surface morphology was investigated by atomic force microscopy (AFM). The structure of samples was analyzed using the XRD technique, and the surface wettability was evaluated. Results: The surface roughness of the samples was evaluated via root mean square (RMS) parameter. Baseline BioHPP specimens exhibited higher roughness values compared to the other analyzed groups. The roughness of the non-treated specimens (0) decreased in the line 59.18→28.84→14.51 nm. Treatment of the samples by brushing and ultrasonic scaling was associated with an increase in surface roughness. Variations in water contact angle values were observed. However, no consistent treatment-related trend could be established. Conclusions: Composite veneered BioHPP showed a tendency toward higher surface resistance to brushing and ultrasonic scaling. These findings should be interpreted within the limitations of an in vitro descriptive study.

1 May 2026 in Structural Integrity and Life
Verified
Journal Article
Closed access
LŽLuka Župac
Luka Župac
MTMilan Travica
Milan Travica
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
IDIgor Djordjevic
Igor Djordjevic
MPMirjana Perić
Mirjana Perić
Nenad MitrovicNenad Mitrovic
Nenad Mitrovic
This study aims to investigate biomechanical behaviour of the bond between prefabricated acrylic teeth and heat-polymerised denture base resin under different loading angles, using 2D Digital Image Correlation method (2D DIC), a method that enables real-time, full-field analysis of displacement and deformation field. The experimental setup involves samples loaded at 45° and 90°, representing clinically relevant angulations that simulate forces encountered during mastication. A two-part positioning tool is developed via 3D printing to guarantee uniform samples positioning. Stochastic pattern is applied to each sample to enable 2D DIC method tracking. 2D DIC enables visualisation of displacement and von Mises strain fields, particularly in the critical regions of the tooth-resin interface. The results show differences in force, deformation, and displacement between samples angle loaded both at 90° and 45°. That suggests significant impact of loading angle and contact area between tooth and denture base.

25 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
MPMirjana Perić
Mirjana Perić
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
AGAleksandra Špadijer Gostović
Aleksandra Špadijer Gostović
DSDragan Milorad Stanimirović
Dragan Milorad Stanimirović
MKMarina Kostić
Marina Kostić
VPVladimir Pavlovic
Vladimir Pavlovic
Objective: The purpose of this study was to evaluate the surface texture and biofilm adhesion of veneered or CAD/CAM milled zirconia (partially stabilized with yttrium) after professional oral hygiene procedures. Samples (4x4 mm, thickness 2 mm; n = 72) were separated from zirconia blanks (3Y-TZP-LA). One group was veenired with ceramics and the other group of samples was CAD/CAM milled. Each group had 2 subgroups: polished and glazed. The samples were subjected to simulated strokes of professional brushing using abrasive paste and ultrasonic scaling. Parameters of surface micromorphology and receptivity to biofilm were calculated before and after simulating the given methods of professional maintenance of oral hygiene. The characteristics of zirconia surface were evaluated by scanning electron microscopy (SEM). Microbial bacterial/fungal species (Staphylococcus aureus, Streptococcus sanguinis and Candida albicans) were used and cultured on the respective sterilized zirconia surfaces. The amount of biofilm formation on zirconia surface was quantified by colony forming unit (CFU) counts. Results: SEM analysis showed the greatest change in surface microtopography after the use of ultrasonic scaling, in glazed zirconia samples. Less formation of colonies on the surface CAD/CAM milled zirconia restorations was observed. Conclusion: Routine methods of professional maintenance of oral hygiene can damage the surface of glazed zirconia restorations.