Katarina Radović

Dr. Katarina Radović


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2021 in Acta Odontologica Scandinavica
Verified
Journal Article
Closed access
KRKatarina Radović
Katarina Radović
BBBožidar Brković
Božidar Brković
JRJelena Roganović
Jelena Roganović
JIJugoslav Ilić
Jugoslav Ilić
ALAleksandra Milić Lemić
Aleksandra Milić Lemić
BJBoris Jovanović
Boris Jovanović
Oral wound healing in healthy could be promoted by VEGF in saliva, and immediate denture wearing, but data in type 2 diabetes are lacking. Aims were to investigate the timeline of extraction wound ...

17 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
PMPeter Majeric
Peter Majeric
VLVojkan Lazić
Vojkan Lazić
Jelena MilasinJelena Milasin
Jelena Milasin
Milica Jaksic KarisikMilica Jaksic Karisik
Milica Jaksic Karisik
KRKatarina Radović
Katarina Radović
Nickel–titanium alloys used in dentistry have a variety of mechanical, chemical, and biofunctional properties that are dependent on the manufacturing process. The aim of this study was to compare the mechanical and biofunctional performances of a nickel–titanium alloy produced by the continuous casting method (NiTi-2) with commercial nitinol (NiTi-1) manufactured by the classical process, i.e., from remelting in a vacuum furnace with electro-resistive heating and final casting into ingots. The chemical composition of the tested samples was analyzed using an energy dispersive X-ray analysis (EDX) and X-ray fluorescence (XRF). Electron backscatter diffraction (EBSD) quantitative microstructural analysis was performed to determine phase distribution in the samples. As part of the mechanical properties, the hardness on the surface of samples was measured with the static Vickers method. The release of metal ions (Ni, Ti) in artificial saliva (pH 6.5) and lactic acid (pH 2.3) was measured using a static immersion test. Finally, the resulting corrosion layer was revealed by means of a scanning electron microscope (SEM), which allows the detection and direct measurement of the formatted oxide layer thickness. To assess the biocompatibility of the tested nickel–titanium alloy samples, an MTT test of fibroblast cellular proliferation on direct contact with the samples was performed. The obtained data were analyzed with the IBM SPSS Statistics v22 software. EDX and XRF analyses showed a higher presence of Ni in the NiTi-2 sample. The EBSD analysis detected an additional NiTi2-cubic phase in the NiTi-2 microstructure. Additionally, in the NiTi-2 higher hardness was measured. An immersion test performed in artificial saliva after 7 days did not induce significant ion release in either group of samples (NiTi-1 and NiTi-2). The acidic environment significantly increased the release of toxic ions in both types of samples. However, Ni ion release was two times lower, and Ti ion release was three times lower from NiTi-2 than from NiTi-1. Comparison of the cells’ mitochondrial activity between the NiTi-1 and NiTi-2 groups did not show a statistically significant difference. In conclusion, we obtained an alloy of small diameter with an appropriate microstructure and better response compared to classic NiTi material. Thus, it appears from the present study that the continuous cast technology offers new possibilities for the production of NiTi material for usage in dentistry.

11 January 2024 in Metals
Verified
Journal Article
Open access
PDF file
Minja Miličić LazićMinja Miličić Lazić
Minja Miličić Lazić
DTDijana Mitic (former Trisic)
Dijana Mitic (former Trisic)
KRKatarina Radović
Katarina Radović
IDIgor Djordjevic
Igor Djordjevic
PMPeter Majeric
Peter Majeric
Branimir GrgurBranimir Grgur
Branimir Grgur
Variations in the corrosion behavior of biomedical NiTi alloys in Cl− containing and acidic environments present a problem with their biological implantation. The objective of this research was to evaluate the synergy of the microstructure, the corrosion behavior, and the biocompatibility of novel continuous-cast NiTi alloys and to compare them with commercial NiTi alloys. The two alloys have a practically identical nominal chemical composition, but they differ in production technology. The continuous casting technology involved vacuum induction melting of the basic components and vertical continuous casting, while the commercial NiTi alloy was produced through a process of casting, hot rolling, and forming into square shapes. The microstructure was revealed to determine the surface area and size of grains. The corrosion of a commercial nickel–titanium alloy and one prepared by a novel continuous casting method in acidic and chloride-containing solutions was studied via analytical and electrochemical tests. Localized corrosion characteristics related to oxide properties, when exposed to 9 g L−1 NaCl solution, were examined with focused ion beam analysis and subsequent microchemical analysis of the formed corrosive products. Corrosion potential over time and the oxide film resistance were analyzed using linear polarization measurements. To obtain a preliminary estimate of biocompatibility, human fibroblast cells were used in indirect contact, i.e., alloy conditioning medium. The continuous casting method resulted in a reduction in the average grain size in comparison to the commercial sample and better corrosion stability of the sample in an acidic environment. Also, in a solution of 9 g L−1 NaCl the commercial sample showed high values for the corrosion current density (jcorr = 6 μA cm−2), which indicated low corrosion resistance, while the continuous casting sample possessed much better corrosion stability and lower values for the corrosion current density (jcorr = 0.2 μA cm−2). In line with that, elemental analysis of the corroded surfaces showed higher Cl− ion deposition over the surface layer of the commercial sample, suggesting local oxide breakdown. Moreover, NiTicc reached a value three times higher for polarization resistance (Rp = 270 kΩ cm2) over time in comparison to the commercial sample (Rp~100 kΩ cm2). Biocompatibility evaluation showed that human fibroblast cells exhibited altered metabolic activity. An MTT assay showed that cells’ mitochondrial activity dropped below that of control cells in the presence of both materials’ supernatants.

14 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
AGAleksandra Špadijer Gostović
Aleksandra Špadijer Gostović
ARAleksandar Racić
Aleksandar Racić
ATAleksandar Todorović
Aleksandar Todorović
KRKatarina Radović
Katarina Radović
AČAleksandra Dragoljub Čairović
Aleksandra Dragoljub Čairović
IJIvana Vlatković Jakovljević
Ivana Vlatković Jakovljević
The aim of this article was to evaluate properties of new polymer material, based on PEEK, for FPDs in patients with parafunctions. Methods: Prospective clinical study involved patients with diagnosed signs and symptoms of parafunctions, restored with 100 units, PEEK based FPDs, veneered with composite material. During one year observation period the following parameters were evaluated: color changes, periodontal indices, treatment success using FDI criteria, occlusal parameters, patient-reported outcome measures (OHIP-49) and occurrence of complications. Results: Spectrophotometry revealed that 63% of bridges experienced changes for L*, a*, b* color parameters, but it was not clinically significant for patients. Periodontal indices (PI, GI, BOP) revealed statistically significant higher values around restorations. According to FDI criteria, therapy was considered successful and 86.7% of FPDs were acceptable. Computerized occlusal analysis demonstrated no significant difference in the number of occlusal contacts and the intensity of relative forces between restoration and control side. Results of OHIP-49 questionnaire showed improved patient’s quality of life. Complications appeared in a limited number of cases. Conclusion: PEEK based FPDs could be indicated for successful prosthodontic rehabilitation in patients with parafunctional activities, but further material improvements and long-term clinical trials should be conducted to analyze performance of this material in challenging cases, for patients with CMD and in implant therapy.