Larissa Alves

Dr. Larissa Alves


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
LALarissa Alves
Larissa Alves
LCLisseth Patricia Claudio Contreras
Lisseth Patricia Claudio Contreras
MBMirian Galvão Bueno
Mirian Galvão Bueno
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
EBEduardo Bresciani
Eduardo Bresciani
RMRenata Marques de Melo
Renata Marques de Melo
This study evaluated the influence of zirconia surface finishes on the wear of an enamel analogue. 40 zirconia discs were divided into four groups: control (without finish); glazed; polished; polished and glazed. All samples were subjected to wear against steatite antagonists. The specimens underwent roughness, topographic, scanning electron microscopy (SEM) and wettability analyses. Quantitative wear measurements were performed on both steatites and discs. To measure wear of steatites the weight before and after the test and the diameter after the test were used. Profilometer measurements were performed to determine the wear on discs. Roughness, volumetric wear and mass loss were analyzed using the Kruskal-Wallis and Dunn tests (5%), while contact angle values were analyzed with One-way ANOVA and Tukey tests (5%). The polished group had the lowest roughness means, being statistically different from the other groups (p-value=0.0001). The glazed group presented the lowest steatite volumetric wear (p-value=0.0001), but not statistically different from the polished and glazed group, whereas these groups presented the highest zirconia volumetric wear, with statistically different (p-value=0.0002) compared to the others. SEM showed irregularities on the control groups surface, grooves on the polished group, and a homogeneous surface for the glazed group with a few pores. All groups presented contact angles lower than 90 degrees, characterizing hydrophilic surfaces. It can be concluded that just glazed zirconia caused less wear on the antagonist when compared to no finish and polished zirconia.
1

9 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
Claudinei dos SantosClaudinei dos Santos
Claudinei dos Santos
LALarissa Alves
Larissa Alves
EJErnesto B. B Benalcázar Jalkh
Ernesto B. B Benalcázar Jalkh
HSHenrico Strazzi-Sahyon
Henrico Strazzi-Sahyon
EBEstevam A. Bonfante
Estevam A. Bonfante

1 October 2019 in Brazilian Dental Journal
Verified
Journal Article
Open access
João Paulo Mendes TribstJoão Paulo Mendes Tribst
João Paulo Mendes Tribst
LALarissa Alves
Larissa Alves
Amanda Dal PivaAmanda Dal Piva
Amanda Dal Piva
RMRenata Marques de Melo
Renata Marques de Melo
Alexandre BorgesAlexandre Borges
Alexandre Borges
Marco BottinoMarco Bottino
Marco Bottino
The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.

10 June 2022 in Journal of Dental Research
Verified
Journal Article
Open access
LALarissa Alves
Larissa Alves
CRC.S. Rodrigues
C.S. Rodrigues
SVS. Vardhaman
S. Vardhaman
CSC. Saunders
C. Saunders
JSJ.M. Schneider
J.M. Schneider
YZYu Zhang
Yu Zhang
Two damage regimes—“brittle” and “ductile”—have been identified in the literature on ceramic grinding, machining, grit blasting, and wear. In the brittle regime, the damage mechanism is essentially crack formation, while in the ductile region, it is quasiplasticity. Onset of the brittle mode poses the greater threat to strength, so it becomes important to understand the mechanics of ductile–brittle thresholds in these materials. Controlled microcontact tests with a sharp indenter are employed to establish such thresholds for a suite of contemporary computer-aided design/computer-aided manufacturing dental ceramics. Plots of flexural strength S versus indentation load P show a steep decline beyond the threshold, consistent with well-established contact mechanics relations. Threshold dimensions occur on a scale of order 1 µm and contact load of order 1 N, values pertinent to practical grit finishing protocols. The ductile side of ceramic shaping is accessed by reducing grit sizes, applied loads, and depths of cut below critical levels. It is advocated that critical conditions for ductile shaping may be most readily quantified on analogous S( P) plots, but with appropriate machining variable (grit size, depths of cut, infeed rate) replacing load P. Working in the ductile region offers the promise of compelling time and cost economies in prosthesis fabrication and preparation.

1 July 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
GRG.F. Ramos
G.F. Ramos
NRNathalia Ramos
Nathalia Ramos
LALarissa Alves
Larissa Alves
MKMarina Kaizer
Marina Kaizer
Alexandre BorgesAlexandre Borges
Alexandre Borges
RMR.M. Melo
R.M. Melo

1 January 2020 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
CLCarolina Machado Martinelli Lobo
Carolina Machado Martinelli Lobo
SSSâmia Carolina Mota Cavalcanti Sacorague
Sâmia Carolina Mota Cavalcanti Sacorague
NSNathalia Ramos da Silva
Nathalia Ramos da Silva
ACAnna Karina Figueiredo Costa
Anna Karina Figueiredo Costa
LALarissa Alves
Larissa Alves
RMRenata Marques de Melo
Renata Marques de Melo
Glaze application on monolithic zirconia (Y-TZP) can be a practical approach to improve the mechanical properties of this material. Objective Our study evaluated the effect of glazing side and mechanical cycling on the biaxial flexure strength (BFS) of a Y-TZP. Methodology Eighty sintered Y-TZP discs (Ø:12 mm; thickness: 1.2 mm - ISO 6872) were produced and randomly assigned into eight groups (n=10), according to the factors “glazing side” (control – no glazing; GT – glaze on tensile side; GC – glaze on compression side; GTC – glaze on both sides) and “mechanical aging” (non-aged and aged, A – mechanical cycling: 1.2×106, 84 N, 3 Hz, under water at 37°C). Specimens were subjected to BFS test (1 mm/min; 1,000 Kgf load cell) and fractured surfaces were analyzed by stereomicroscopy and SEM. Hsueh’s rigorous solutions were used to estimate the stress at failure of glazed specimens. Two-way ANOVA, Tukey’s test (5%), and Weibull analysis were performed. Results The “glazing side”, “mechanical aging” and the interaction of the factors were significant (p<0.05). Groups GC (1157.9±146.9 MPa), GT (1156.1±195.3 MPa), GTC (986.0±187.4 MPa) and GTC-A (1131.9±128.9 MPa) presented higher BFS than control groups (Tukey, 5%). Hsueh’s rigorous solutions showed that the maximum tensile stress was presented in the bottom of zirconia layer, at the zirconia/glaze interface. Weibull characteristic strength (σo) of the GC was higher than all groups (p<0.05), except to GT, GTC-A and GTC, which were similar among them. The fractography showed initiation of failures from zirconia the tensile side regardless of the side of glaze application and fatigue. Conclusion Glazing zirconia applied on both tensile and compression sides improves the flexural strength of Y-TZP, regardless the mechanical aging.