Lisseth Patricia Claudio Contreras

Lisseth Patricia Claudio Contreras

Auto-generated profile, based on publicly available information

Lisseth Patricia Claudio Contreras

São Paulo State University (Unesp), Institute of Science and Technology at São José dos Campos, Department of Dental Materials and Prosthodontics, São José dos Campos, SP, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Operative Dentistry
Verified
Journal Article
Closed access
APAmo Dal Piva
Amo Dal Piva
LCLpc Contreras
Lpc Contreras
FRFc Ribeiro
Fc Ribeiro
LALc Anami
Lc Anami
SCSea Camargo
Sea Camargo
Marco BottinoMarco Bottino
Marco Bottino
SUMMARY: Introduction: This study evaluated the morphology, biofilm formation, and viability of human gingival fibroblasts in contact with two monolithic ceramics after two different finishing techniques: polishing or glazing. For this, 92 blocks (4.5 × 4.5 × 1.5 mm) of each ceramic were made using high translucency zirconia partially stabilized by yttrium (YZHT) and lithium silicate reinforced by zirconium (ZLS). Methods and Materials: Blocks were sintered and then divided into glazing (g) or polishing (p) surface finish. Surface roughness (Ra and RSm) was evaluated through a contact rugosimeter and profilometry. Specimens were contaminated for heterotypic biofilm formation with Streptococcus mutans, Streptococcus sanguinis and Candida albicans for 16 hours. Biofilm was quantified by counting the colony forming units (CFU/mL) and analyzed by scanning electron microscopy (SEM). Fibroblast viability was evaluated by MTT assay. Surface free energy (SFE) was also determined. Roughness data were evaluated using nonparametric tests, while SFE, MTT and CFU results were evaluated by analysis of variance and Tukey test, and MTT data were also submitted to t-test (all, α=0.05). Results: Results showed that polished samples presented a lower high profile mean (p<0.001); however, YZHTg presented less space between defects (p=0.0002). SFE showed that YZHT presented higher SFE than ZLS. Profilometry evidenced more homogeneity on polished surfaces. The interaction of finishing technique and microorganisms influenced the CFU (p=0.00). MTT assay demonstrated initial severe cytotoxic behavior for polished surfaces. SEM images showed homogeneous surfaces, except for glazed YZHT. Conclusion: Glazed surfaces have a greater roughness and tend to accumulate more biofilm. Polished surfaces have higher SFE; however, they are temporarily cytotoxic.

1 November 2018 in Operative Dentistry
Verified
Journal Article
Closed access
LCLpc Contreras
Lpc Contreras
APAmo Dal Piva
Amo Dal Piva
FRFc Ribeiro
Fc Ribeiro
LALc Anami
Lc Anami
SCSea Camargo
Sea Camargo
Marco BottinoMarco Bottino
Marco Bottino
SUMMARY: Purpose: Feldspathic ceramic restorations can be obtained by different techniques (stratification or computer-aided design/computer-aided manufacturing [CAD/CAM] blocks) and finishing procedures (polishing or glaze application). This study evaluated the effects of techniques and finishing procedures on surface properties, biofilm formation, and viability of human gingival fibroblasts (FMM-1) in contact with these materials.Methods and Materials: Ceramic specimens were obtained through a stratification technique (Vita VM9) and from CAD/CAM blocks (Vita Blocs Mark II; both Vita Zahnfabrik) and their surfaces were finished by polishing (ceramisté diamond rubbers + polishing paste; “p” subgroups) or glaze spray application + sintering (“g” subgroups). Roughness (Ra and RSm parameters) and surface free energy (SFE) were measured. Early biofilm formation of Streptococcus mutans, Streptococcus sanguinis, and Candida albicans was evaluated by counting colony-forming units (CFU). MTT (3-[4.5-dimethyl-thiazol-2-yl-]-2.5-diphenyl tetrazolium bromide) cytotoxicity test evaluated cellular viability for the growth of FMM-1 after 24 hours and seven days of contact. Scanning electron microscopy (SEM) and three-dimensional optical profilometry were performed to qualitatively analyze the surface. Data were analyzed by analysis of variance, Tukey test, and t-test (all α=0.05).Results: Polished samples presented lower roughness (Ra, p=0.015; RSm, p=0.049) and higher SFE (p=0.00). Streptococci had higher CFU in all groups, but the CFU of C albicans was lower for polished samples. Biofilm formation was influenced by the interaction of all factors (p=0.018), and the materials showed no cytotoxicity to FMM-1 growth.Conclusions: Polishing resulted in the lowest values for surface roughness and higher SFE values. Polished ceramics showed less C albicans adherence while the adherence of Streptococci was greater than C albicans in all conditions.

1 October 2019 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
LALarissa Alves
Larissa Alves
LCLisseth Patricia Claudio Contreras
Lisseth Patricia Claudio Contreras
MBMirian Galvão Bueno
Mirian Galvão Bueno
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
EBEduardo Bresciani
Eduardo Bresciani
RMRenata Marques de Melo
Renata Marques de Melo
This study evaluated the influence of zirconia surface finishes on the wear of an enamel analogue. 40 zirconia discs were divided into four groups: control (without finish); glazed; polished; polished and glazed. All samples were subjected to wear against steatite antagonists. The specimens underwent roughness, topographic, scanning electron microscopy (SEM) and wettability analyses. Quantitative wear measurements were performed on both steatites and discs. To measure wear of steatites the weight before and after the test and the diameter after the test were used. Profilometer measurements were performed to determine the wear on discs. Roughness, volumetric wear and mass loss were analyzed using the Kruskal-Wallis and Dunn tests (5%), while contact angle values were analyzed with One-way ANOVA and Tukey tests (5%). The polished group had the lowest roughness means, being statistically different from the other groups (p-value=0.0001). The glazed group presented the lowest steatite volumetric wear (p-value=0.0001), but not statistically different from the polished and glazed group, whereas these groups presented the highest zirconia volumetric wear, with statistically different (p-value=0.0002) compared to the others. SEM showed irregularities on the control groups surface, grooves on the polished group, and a homogeneous surface for the glazed group with a few pores. All groups presented contact angles lower than 90 degrees, characterizing hydrophilic surfaces. It can be concluded that just glazed zirconia caused less wear on the antagonist when compared to no finish and polished zirconia.
1

1 December 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
LALarissa Alves
Larissa Alves
LCLisseth Patricia Claudio Contreras
Lisseth Patricia Claudio Contreras
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
Marco BottinoMarco Bottino
Marco Bottino
LVLuiz Felipe Valandro
Luiz Felipe Valandro
RMRenata Marques de Melo
Renata Marques de Melo

10 December 2018 in Odontología Sanmarquina
Verified
Journal Article
Open access
PDF file
JMJaiane Bandoli Monteiro
Jaiane Bandoli Monteiro
LCLisseth Patrícia Cláudio Contreras
Lisseth Patrícia Cláudio Contreras
TCThaiana Damasceno Cunha
Thaiana Damasceno Cunha
LLLuís Paulo Vasconcelos de Castro Leite
Luís Paulo Vasconcelos de Castro Leite
JVJalon De Morais Vieira
Jalon De Morais Vieira
ISIvone De Oliveira Salgado
Ivone De Oliveira Salgado
Objetivo: El objetivo de este estudio fue medir el cambio dimensional de una silicona por condensación a través de diferentes instrumentos de medición (calibrador digital, estereomicroscopio y máquina de medición por coordenadas tridimensional) en cuatro diferentes tiempos. Métodos: En el estudio experimental in vitro se realizaron cuatro impresiones con silicona por condensación (Speedex) con un dispositivo específico con cuatro distancias, con un total de 16 mediciones llevadas a cabo con cada instrumento. Los tiempos predeterminados de medición fueron: inmediatamente después de la impresión (T0), después de 30 minutos (T1), 1 h (T2) y 7 días (T3) de la impresión. Las medias y desviaciones estándar de las mediciones se analizaron con prueba de varianza y la prueba de Tukey, con un nivel de significancia de 0,05. Resultados: La media (mm) para las muestras medidas con el calibrador digital (T0= 5,82; T1 y T2= 5,8; T3= 5,78) y la máquina de medición por coordenadas tridimensional (T0= 5,75; T1= 5,78; T2 y T3= 5,77), presentaron diferencia estadísticamente significativa de la dimensión de los valores iniciales para los valores después de 7 días (p = 0,037; p = 0,013, respectivamente), la misma no se dio para el uso del estereomicroscopio (T0, T1 y T3= 5,83; y T2 = 5,81), que presentó similitud estadística en todos los tiempos (p = 0,754). Conclusiones: El método de medición fue el factor relevante que influenció en los resultados de las dimensiones de las impresiones, los cuatro tiempos no fueron relevantes en los cambios dimensionales de la silicona de condensación analizada.