A sensorless control algorithm not only reduces the cost of a permanent magnet synchronous motor (PMSM) system, but also broadens its application scope. Expanding speed threshold and enhancing dynamic performance are crucial aspects. To optimize the adaptability of observers and the immunity of the controller in a full-speed domain, an improved sensorless control scheme for a PMSM based on a hybrid position observer and disturbance compensation is proposed. Firstly, the precise detection of the initial position and the scheme of starting with the load at any position are proposed based on high-frequency rotation injection, magnetic pole direction calibration and square-wave high-frequency injection (HFI). Secondly, a higher-order sliding mode observer (HSMO) is designed to improve high-speed observation performance by introducing an extended electromotive force (EEMF). Correspondingly, a speed controller called PI plus is developed utilizing a reverse control algorithm and the observed disturbance quantity, which further enhances the system’s disturbance rejection capability. Subsequently, a linearly weighted observer switching method and a linear signal withdrawal scheme are proposed to suppress torque and speed oscillations in medium-speed threshold. Furthermore, a normalized linear extended state observer (LESO) is designed to enhance rotor information estimation accuracy and enable the observation of unknown disturbances in full-speed thresholds. Finally, the effectiveness of the proposed sensorless control system is tested through experiments involving variations in speed, load, and parameter. The experimental results indicate that the proposed sensorless strategy is capable of achieving a loaded start. The designed observer switching strategy and the scheme of injection signal withdrawal contribute to a smoother acceleration process. Furthermore, load variation test results at high-speed thresholds demonstrate that the proposed controller can reduce speed drop by 45 rpm compared to a traditional PI. Additionally, the results of parameter variation testing validate the observer’s robustness in the disturbances of within the range of ±0.3 pu.
Currently, reactive power compensation in wind‐photovoltaic (PV) hybrid grid‐connected systems is typically controlled independently by the wind farm and PV station, lacking a coordination mechanism between them. To address this, we propose a reactive power hierarchical control strategy for wind‐PV hybrid systems. Building on an analysis of reactive power source regulation characteristics and reactive power sensitivity, a three‐layer reactive power control structure for wind‐PV hybrid grid‐connected systems is proposed based on the hierarchical control concept. At the system layer, the reactive power compensation requirements for the entire system are determined using the reactive voltage sensitivity of the system collection bus. At the station layer, reactive power allocation tasks for the wind farm and PV station are determined using a hierarchical optimisation control model. At the equipment layer, reactive power allocation tasks for wind turbines, PV inverters, and dynamic reactive power compensation equipment are determined according to the allocation principles governing reactive power sources within the wind farm and PV station. Compared with traditional control strategy, the control strategy in this paper can make full use of the reactive power control capability of the reactive power sources within the system to achieve optimal allocation of the reactive power compensation tasks in the whole system. The average reduction in system network losses reached 8.14%, and the bus voltage at the collection point could be essentially stabilised around 1.0 pu so as to achieve the purpose of improving the stability of the collection bus voltage of the system and point of common coupling (PCC) bus voltage of the station and reducing the system network loss.
11 June 2024 in IET Generation, Transmission & Distribution
Resilience is one of the main features of smart distribution networks, and a microgrid (MG) access to the distribution network provides an effective way to improve resilience. MG and distribution network belong to different interests, so it is necessary that MGs and flexible resources are actively guided through price leverage. In this way, MGs take part in the post‐disaster restoration and enhance its resilience. Firstly, this paper proposes a dynamic restoration electricity price response mechanism after extreme disasters and constructs a power response model for loads and electric vehicles within the MGs. Secondly, the optimal scheduling model of the distribution network with multiple‐microgrids (MMG) is proposed to improve the restoration rate of critical loads (RRCL). Single microgrid achieves the largest microgrid revenue and restoration contribution, and MMG uses the power headroom index to optimize the dynamic restoration electricity price to achieve the smallest power purchase cost of distribution network. Finally, the optimal scheduling method for resilience enhancement of distribution networks with MMG considering dynamic restoration electricity price response mechanism is validated by dual microgrid access to an IEEE 33‐node distribution system. The simulation results show that the proposed optimization method effectively improves the RRCL of distribution network.
With the rapid integration of distributed energy resources, achieving a balance between economic efficiency and environmental sustainability in multi-microgrid (MMG) systems is critical. However, existing studies typically treat microgrid operators as fully compliant entities. They often neglect the “trust-risk” dimension along with potential default behaviors in decentralized markets. This paper proposes a novel co-optimized scheduling model for urban MMG systems, centered on a unified “Social–Economic–Physical” coupling framework. To ensure transaction integrity, a robust reputation evaluation framework is developed using Root Mean Square Error (RMSE), mean absolute error (MAE), plus Dynamic Time Warping (DTW). This framework effectively identifies fraudulent data or contractual breaches. Furthermore, to enhance fairness while promoting decarbonization, the model integrates a dynamic network pricing strategy based on the Shapley value. It works alongside a reputation-weighted reward–penalty step-type carbon trading scheme. The proposed model is formulated as a mixed-integer linear programming (MILP) problem and solved using MATLAB R2025b with CPLEX 12.10. Simulation results demonstrate that the integrated approach significantly optimizes system performance. Total carbon emissions are reduced by 49.6 tons. Meanwhile, revenues for the MMG Alliance, individual microgrids, and shared energy storage operators increase by 4.08% to 33.00%. The proposed framework provides a practical governance solution for Smart City multi-microgrid systems, effectively addressing the “trust-risk” challenge in decentralized urban energy markets. The findings validate that the proposed mechanism effectively fosters a trustworthy trading environment, achieving a “win-win” outcome for economic profitability and urban energy resilience.
To address the issue that transient voltage cannot be stabilized solely by the system's own reactive power regulation capability after faults occur at some weak nodes in high-penetration wind-photovoltaic hybrid grid-connected system, a dynamic reactive power planning method considering transient voltage stability for high-penetration wind-photovoltaic hybrid grid-connected system is proposed. Based on the system's own reactive power regulation capability, this method constructs a reactive power planning benchmark scenario using typical output scenarios of wind power and photovoltaic power, and determines the installation locations and compensation capacities of the dynamic reactive power compensation devices through multiple power flow calculations. Key fault nodes are identified using transient voltage stability recovery index to preliminarily determine the system's weak nodes. On this basis, sensitivity index are used to determine the installation nodes for dynamic reactive power compensation devices. An optimization model for dynamic reactive power planning is established with the objective of improving system transient voltage stability at the lowest investment cost for dynamic reactive power compensation devices. The compensation capacities at reactive power compensation nodes are optimized using a Particle Swarm Optimization algorithm based on Differential Evolution.
Resilience is one of the main features of smart distribution network, and a microgrid access to the distribution network provides an effective way to improve resilience. Microgrid and distribution network belong to different interests, so it is necessary to use price leverage to actively guide microgrids and flexible resources within microgrid to participate in post-disaster restoration of distribution network and enhance the resilience. Firstly, this paper proposes a dynamic restoration electricity price response mechanism for distribution network after extreme disasters and constructs a power response model for loads and electric vehicles within the microgrid. Secondly, the optimal scheduling model of distribution network with multiple-microgrid is proposed to improve the restoration rate of critical loads(RRCL) in the distribution network. Single microgrid achieves the largest microgrid revenue and restoration contribution, and multi-microgrid uses the power headroom index to optimize the dynamic restoration electricity price to achieve the smallest power purchase cost of distribution network. Finally, the optimal scheduling method for resilience enhancement of distribution networks with MMG considering dynamic restoration electricity price response mechanism is validated by dual microgrid access to IEEE 33-node distribution system. The simulation results show that the proposed optimization method effectively improves the RRCL of distribution network.