The electro-osmosis chemical treatment (ECT) is a useful method for improving soil strength. Some laboratory tests on ECT for strengthening high-salinity soft marine soils were investigated using self-designed laboratory facilities in this research. This study focused on improving the mechanical properties by using ECT method and analyzed the effects of using CaCl2solution on soil strength owing to the electrolyte is an important factor for improving the bearing capacity of the high-salinity marine soils. Three groups of tests with different time for consolidation were performed to analyze the effective consolidation time on the ECT. In addition, several practical issues, including the current, voltage, energy consumption and the bearing capacity of the treated soils before and after experiments, were considered in the tests. The laboratory tests results demonstrated that the ECT technique is an effective method for improving the high-salinity marine soft soils. Furthermore, the definition of the effective time for consolidation was proposed for the ECT of high-salinity soft marine soils to improve the feasibility and economical efficiency of the ECT. This study provides some references and suggestions for practical application of the ECT technique for marine soft soils.
In order to compare and analyze the seismic response characteristics of a safety-related nuclear structure on a non-rock site in the condition of raft and pile group foundations under unidirectional and multidirectional seismic motion input, a large-scale shaking table test of the soil-nuclear structure system was carried out in this paper. In the test, the soil was uniform silted clay, and the shear wave velocity was 213 m/s. Considering the similarity of the superstructure natural frenquency, the actual nuclear power structure was simplified to a three-story frame shear wall structure model. The annular laminated shear model box was used to take the boundary effect of soil into consideration; the seismic motions = were input in only one horizontal direction or three directions at the same time for the shaking table test, and the results were analyzed. The results of the test show that the acceleration response of the safety-related nuclear plant is affected by the directions of input seismic motion and the forms of the foundation. When the seismic motion is input simultaneously in three directions, the acceleration responses of the horizontal motion and vertical rocking of the safety-related plant are larger than those of the single-direction input. The acceleration response of the horizontal motion and vertical rocking of the safety-related structure with the pile group foundation is smaller than that with the raft foundation. The values of most frequency bands in the horizontal acceleration Fourier amplitude spectrum at the top of the pile-foundation structure are smaller than that at the top of the raft-foundation structure, while the displacement is basically the same as that of the raft-foundation structure. This is related to the relation between the frequency component of input seismic motion and the natural frequency of the structure system. Therefore, it is more reasonable to use three-dimensional seismic input in the seismic response analysis of nuclear power plants. The seismic performance of nuclear power plants can be enhanced by using pile group foundations.
Coral sand is characterized by unique particle morphology and pore structure, which result in pronounced dilatancy and a high internal friction angle during shear. The dilatancy angle is a critical parameter for finite element analyses of sand foundation bearing capacity; the inappropriate selection of this parameter can lead to significant computational errors. In this research, a series of consolidated drained triaxial tests were conducted on coral sand samples from the South China Sea to investigate the dilatancy behavior and its effect on shear strength parameters. A dilatancy equation for coral sand was proposed, incorporating the dilatancy index, relative density, and mean effective stress. The results indicate the following: (1) Within the confining pressure range of 25–400 kPa, the stress–strain curves exhibit varying degrees of strain softening. When the effective confining pressure reaches 400 kPa, the dilatant behavior is nearly suppressed, resulting in a transition from dilatancy to contraction; (2) The peak internal friction angle decreases significantly with increasing effective confining pressure. However, the sensitivity to confining pressure varies for samples with different relative densities (Dr = 30–90%), with denser samples showing a more rapid reduction in peak friction angle; (3) At a confining pressure of 25 kPa, the maximum dilatancy angle of coral sand samples reaches 44.2°, significantly exceeding the typical range observed in terrestrial quartz sands. This difference may be attributed to the irregular and angular characteristics of the coral sand particles; (4) Based on Bolton’s dilatancy theory, a dilatancy equation applicable to coral sand was developed, demonstrating a strong linear relationship among the dilatancy index (IR), relative density (Dr), and peak mean effective stress (p′f). These findings provide valuable guidance for the selection of strength parameters for engineering applications involving coral sand.
This study investigates the pile foundation of a nuclear power plant situated on medium-soft soil. It employs an improved viscoelastic artificial boundary unit to accurately simulate the boundary conditions of the calculation area. The research utilizes a constitutive model of concrete damage plasticity for the pile foundation and an equivalent linearized model for the soil layer. Through large-scale shaking table experiments and numerical simulations, we explore the internal force distribution within the nuclear power structure’s pile foundation and assess the extent of the damage. The results indicate that damage primarily occurs in the medium-soft ground, concentrating in the upper part of the pile and affecting the entire cross-section. Subsequent numerical analyses were conducted after reinforcing the soil layer around the top of the pile. The findings demonstrate that this reinforcement leads to a more uniform and rational distribution of internal forces along the pile, significantly reducing damage. Notably, there is no severe damage extending across the entire cross-section after reinforcement. This outcome highlights the potential for improving the force distribution in the pile foundations of nuclear power structures through appropriate soil layer reinforcement. The insights gained from this study provide valuable guidance for the seismic design of nuclear power structures.