Lennart Söder

Prof. Lennart Söder


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2024 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Open access
MAManuel Agredano-Torres
Manuel Agredano-Torres
MZMengfan Zhang
Mengfan Zhang
LSLennart Söder
Lennart Söder
Qianwen XuQianwen Xu
Qianwen Xu
Hydrogen electrolyzers are promising tools for frequency regulation of future power systems with high penetration of renewable energies and low inertia. This is due to both the increasing demand for hydrogen and their flexibility as controllable load. The two main electrolyzer technologies are Alkaline Electrolyzers (AELs) and Proton Exchange Membrane Electrolyzers (PEMELs). However, they have trade-offs: dynamic response speed for AELs, and cost for PEMELs. This paper proposes the combination of both technologies into a Hybrid Hydrogen Electrolyzer System (HHES) to obtain a fast response for frequency regulation with reduced costs. A decentralized dynamic power sharing control strategy is proposed where PEMELs respond to the fast component of the frequency deviation, and AELs respond to the slow component, without the requirement of communication. The proposed decentralized approach facilitates a high reliability and scalability of the system, what is essential for expansion of hydrogen production. The effectiveness of the proposed strategy is validated in simulations and experimental results.

3 November 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
ETEgill Tomasson
Egill Tomasson
LSLennart Söder
Lennart Söder
There is growing concern regarding generation adequacy within the power system industry. The ever-increasing injection of intermittent renewable resources makes it harder than before to estimate the reliability of modern power systems using traditional approaches. This paper develops a framework for estimating the reliability of modern power systems which have considerable levels of wind power generation. Monte Carlo simulation is applied using a very efficient importance sampling technique based on the Cross-Entropy method as well as Copula theory. Tailor-made importance sampling functions for conventional generation, load and wind power generation drastically reduce the number of samples required to estimate reliability parameters of interest. The methodology enables simulation of multi-area power systems with considerable amount of correlated wind power generation in each of the different areas. Simulation results confirm the efficiency as well as the accuracy of the proposed method and show that it is orders of magnitude faster than crude Monte Carlo simulation.

4 October 2018 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
PAPoria Astero
Poria Astero
LSLennart Söder
Lennart Söder
Poria AsteroPoria Astero
Poria Astero
High penetrations of renewable energy sources (RES) in distribution grids lead to new challenges in voltage regulation. These challenges are not just limited to the steady-state voltage rise, but they are extended to rapid voltage changes due to wind speed variations and moving clouds, casting shadow on PV panels. According to EN50160 in LV grids, the steady-state voltage should not exceed 1.1 pu (static characteristic), and voltage rapid changes should be kept less than 0.05 pu (dynamic characteristic). These two characteristics may limit the maximum amount of RES that can be installed in LV grids, called respectively the static hosting capacity (SHC) and dynamic hosting capacity (DHC). Although existing research just evaluated SHC in distribution grids, high penetrated RES grids can be faced with such large voltage changes which cause a smaller DHC than the SHC. This paper studies both SHC and DHC in distribution grids and proposes an adaptive controller for STATCOMs to regulate steady-state and dynamic voltage while avoiding unnecessary increase in reactive power. The simulation results in some German distribution grids show considerable effects of the proposed adaptive controller on improving both SHC and DHC.

1 July 2007
Verified
Conference Paper
Closed access
EBElin Brostrom
Elin Brostrom
JAJesper Ahlberg
Jesper Ahlberg
LSLennart Söder
Lennart Söder
In this paper a technique of modelling severe weather for power system reliability calculations is developed. The model is based on geographically moving winds and precipitation and is suitable for transmission network. A scenario represents a weather situation with given parameters. Besides the weather model a stochastic vulnerability model for the components is required for each scenario that connects the risk of failure to the weather situation. In order to mitigate severe consequences of future ice storms in an efficient way it is essential to be able to estimate the consequences based on assumptions of the technical system and the severity of possible storms. It is assumed that the probability of a failure due to a given weather depends on load functions for wind and ice together with the component vulnerability model which is based on the design of the components. The wind load is direct and the ice load is given by a known ice accretion model. Conclusions about the reliability of the studied lines under ice storms are presented as well as a graph of the critical conditions for the studied lines with ice thickness on the x-axis and gust wind on the y-axis. The numerical examples show the impact of different weather situations on a part of the Swedish Transmission network using data both from real weather situations in Sweden and the weather model.

30 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
KNKena Likassa Nefabas
Kena Likassa Nefabas
LSLennart Söder
Lennart Söder
MMMengesha Mamo
Mengesha Mamo
JOJon Olauson
Jon Olauson
Ethiopia has huge wind energy potential. In order to be able to simulate the power system operation, hourly time series of wind power is needed. These can be obtained from ERA5 data but first a realistic model is needed. Therefore, in this paper ERA5 reanalysis data were used to model wind power production at two topographically different and distant regions of Ethiopian wind farms—Adama II and Ashegoda. Wind speed was extracted from the ERA5 nearest grid point, bi-linearly interpolated to farms location and statistically down-scaled to increase its resolution at the site. Finally, the speed is extrapolated to hub-height of turbine and converted to power through farm specific power curve to compare with actual data for validation. The results from the model and historical data of wind farms are compared using performance error metrics like hourly mean absolute error (MAE) and hourly root mean square error (RMSE). When comparing with data from Ethiopian Electric Power (EEP), we found hourly MAE and RMSE of 2.5% and 4.54% for Adama II and 2.32% and 5.29% for Ashegoda wind farms respectively, demonstrating a good correlation between the measured and our simulation model result. Thus, this model can be extended to other parts of the country to forecast future wind power production, as well as to indicate simulation of wind power production potential for planning and policy applications using ERA5 reanalysis data. To the best of our knowledge, such modeling of wind power production using reanalysis data has not yet been tried and no researcher has validated generation output against measurement in the country.

8 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
HNHenrik Nordström
Henrik Nordström
LSLennart Söder
Lennart Söder
DFDamian Flynn
Damian Flynn
JMJulia Matevosyan
Julia Matevosyan
JKJuha Kiviluoma
Juha Kiviluoma
BHBri-Mathias Hodge
Bri-Mathias Hodge
The use of wind power has grown strongly in recent years and is expected to continue to increase in the coming decades. Solar power is also expected to increase significantly. In a power system, a continuous balance is maintained between total production and demand. This balancing is currently mainly managed with conventional power plants, but with larger amounts of wind and solar power, other sources will also be needed. Interesting possibilities include continuous control of wind and solar power, battery storage, electric vehicles, hydrogen production, and other demand resources with flexibility potential. The aim of this article is to describe and compare the different challenges and future possibilities in six systems concerning how to keep a continuous balance in the future with significantly larger amounts of variable renewable power production. A realistic understanding of how these systems plan to handle continuous balancing is central to effectively develop a carbon-dioxide-free electricity system of the future. The systems included in the overview are the Nordic synchronous area, the island of Ireland, the Iberian Peninsula, Texas (ERCOT), the central European system, and Great Britain.