Xiaodong Li

Dr. Xiaodong Li


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
XLXiaodong Li
Xiaodong Li
RWRong-wei Wen
Rong-wei Wen
DDDehao Duanmu
Dehao Duanmu
WHWei Huang
Wei Huang
KWKinto Wan
Kinto Wan
YHYong Hu
Yong Hu
A bionic robotic hand can perform many movements similar to a human hand. However, there is still a significant gap in manipulation between robot and human hands. It is necessary to understand the finger kinematics and motion patterns of human hands to improve the performance of robotic hands. This study aimed to comprehensively investigate normal hand motion patterns by evaluating the kinematics of hand grip and release in healthy individuals. The data corresponding to rapid grip and release were collected from the dominant hands of 22 healthy people by sensory glove. The kinematics of 14 finger joints were analyzed, including the dynamic range of motion (ROM), peak velocity, joint sequence and finger sequence. The results show that the proximal interphalangeal (PIP) joint had a larger dynamic ROM than metacarpophalangeal (MCP) and distal interphalangeal (DIP) joints. Additionally, the PIP joint had the highest peak velocity, both in flexion and extension. For joint sequence, the PIP joint moved prior to the DIP or MCP joints during flexion, while extension started in DIP or MCP joints, followed by the PIP joint. Regarding the finger sequence, the thumb started to move before the four fingers, and stopped moving after the fingers during both grip and release. This study explored the normal motion patterns in hand grip and release, which provided a kinematic reference for the design of robotic hands and thus contributes to its development.

18 April 2024 in Journal of Neurorestoratology
Verified
Journal Article
Open access
XLXiaodong Li
Xiaodong Li
JWJunlin Wang
Junlin Wang
XCXiang Cao
Xiang Cao
YHYong Huang
Yong Huang
WHWei Huang
Wei Huang
SXSheng Quan Xie
Sheng Quan Xie

15 December 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
DDDehao Duanmu
Dehao Duanmu
XLXiaodong Li
Xiaodong Li
WHWei Huang
Wei Huang
YHYong Hu
Yong Hu
The development of soft robotics owes much to the field of biomimetics, where soft actuators predominantly mimic the movement found in nature. In contrast to their rigid counterparts, soft robots offer superior safety and human–machine interaction comfort, particularly in medical applications. However, when it comes to the hand rehabilitation exoskeletons, the soft devices have been limited by size and material constraints, unable to provide sufficient tensile strength for patients with high muscle tension. In this paper, we drew inspiration from the muscle structure found in the tail of dragonflies and designed a novel central tendon-based bellows actuator. The experimental results demonstrated that the central tendon-based bellows actuator significantly outperforms conventional pneumatic bellows actuators in terms of mechanical output. The tensile strength of the central tendon-based bellows actuator exceeded that of pneumatic actuators more than tenfold, while adding only 2 g to the wearable weight. This finding suggests that the central tendon-based bellows actuator is exceptionally well-suited for applications demanding substantial pulling force, such as in the field of exoskeleton robotics. With tensile strength exceeding that of pneumatic bellows actuators, this biomimetic design opens new avenues for safer and more effective human–machine interaction, revolutionizing various sectors from healthcare to industrial automation.

15 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
XLXiaodong Li
Xiaodong Li
SYSHUOHENG YANG
SHUOHENG YANG
NFNingbo Fei
Ningbo Fei
JWJunlin Wang
Junlin Wang
WHWei Huang
Wei Huang
YHYong Hu
Yong Hu
The application of wearable electroencephalogram (EEG) devices is growing in brain–computer interfaces (BCI) owing to their good wearability and portability. Compared with conventional devices, wearable devices typically support fewer EEG channels. Devices with few-channel EEGs have been proven to be available for steady-state visual evoked potential (SSVEP)-based BCI. However, fewer-channel EEGs can cause the BCI performance to decrease. To address this issue, an attention-based complex spectrum–convolutional neural network (atten-CCNN) is proposed in this study, which combines a CNN with a squeeze-and-excitation block and uses the spectrum of the EEG signal as the input. The proposed model was assessed on a wearable 40-class dataset and a public 12-class dataset under subject-independent and subject-dependent conditions. The results show that whether using a three-channel EEG or single-channel EEG for SSVEP identification, atten-CCNN outperformed the baseline models, indicating that the new model can effectively enhance the performance of SSVEP-BCI with few-channel EEGs. Therefore, this SSVEP identification algorithm based on a few-channel EEG is particularly suitable for use with wearable EEG devices.

23 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
XLXiaodong Li
Xiaodong Li
RWRong-wei Wen
Rong-wei Wen
DDDehao Duanmu
Dehao Duanmu
KWKinto Wan
Kinto Wan
WHWei Huang
Wei Huang
YHYong Hu
Yong Hu
Bionic robotic hand can perform many movements similar to human hand. But there is still a significant gap in manipulation between robot and human hand. It is necessary to understand the finger kinematics and motion patterns of human hand to improve the performance of robotic hand. This study aimed to comprehensively investigate normal hand motion patterns by evaluating the kinematics of hand grip and release in healthy individuals. The data corresponding to rapid grip and release were collected from the dominant hand of 22 healthy people by sensory glove. The kinematics of 14 finger joints were analyzed, including the dynamic range of motion (ROM), peak velocity, joint sequence and finger sequence. The results show that the proximal interphalangeal (PIP) joint had a largest dynamic ROM than metacarpophalangeal (MCP) and distal interphalangeal (DIP) joints. Besides, the PIP joint had the highest peak velocity, both in flexion and extension. For joint sequence, the PIP joint moved prior to the DIP or MCP joints during flexion, while extension started in DIP or MCP joints, followed by PIP joint. Regarding the finger sequence, the thumb started to move before four fingers, and stopped moving after the fingers during both grip and release. This study explored the normal motion patterns in hand grip and release, which provided kinematic reference for the design of robotic hand and thus contribute to its development.

29 August 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XLXiaodong Li
Xiaodong Li
XWXin Wang
Xin Wang
SCShihao Chen
Shihao Chen
WZWenxuan Zhu
Wenxuan Zhu
RJRichu Jin
Richu Jin
WPWeiwei Peng
Weiwei Peng
While established neuromodulation techniques like transcranial magnetic stimulation and transcranial direct current stimulation have shown potential for enhancing brain-computer interface (BCI) performance, their clinical adoption faces challenges including high implementation costs, technical complexity, and safety concerns. This study investigated binaural beats (BB), a non-invasive auditory neuromodulation method characterized by operational simplicity and minimal adverse effects, as a practical alternative for optimizing auditory P300-BCI. Employing a crossover experimental design, thirty healthy participants underwent gamma-band (40 Hz) and alpha-band (10 Hz) BB stimulation in separate sessions. Auditory oddball paradigm experiments were conducted before and after each BB intervention. Electroencephalogram (EEG) data were decoded using both a machine learning classifier and a deep learning model for P300 classification. Additionally, irregular-resampling auto-spectral analysis (IRASA) was applied to extract aperiodic components from EEG during BB stimulation to evaluate changes in brain state. The results demonstrated frequency-dependent modulation effects: gamma-BB significantly improved P300 classification accuracy while alpha-BB impaired performance. Neurophysiological analysis revealed that gamma-BB decreased the aperiodic exponent, indicating enhanced brain arousal level, whereas alpha-BB produced the opposite pattern. Importantly, the aperiodic parameter change showed a significant association with BCI performance improvement. These findings established gamma-BB as an effective, low-cost neuromodulation strategy for augmenting auditory P300-BCI through brain state modulation.