Soft robotic glove with brain computer interfaces (BCI) control has been used for post-stroke hand function rehabilitation. Motor imagery (MI) based BCI with robotic aided devices has been demonstrated as an effective neural rehabilitation tool to improve post-stroke hand function. It is necessary for a user of MI-BCI to receive a long time training, while the user usually suffers unsuccessful and unsatisfying results in the beginning. To propose another non-invasive BCI paradigm rather than MI-BCI, steady-state visually evoked potentials (SSVEP) based BCI was proposed as user intension detection to trigger the soft robotic glove for post-stroke hand function rehabilitation. Thirty post-stroke patients with impaired hand function were randomly and equally divided into three groups to receive conventional, robotic, and BCI-robotic therapy in this randomized control trial (RCT). Clinical assessment of Fugl-Meyer Motor Assessment of Upper Limb (FMA-UL), Wolf Motor Function Test (WMFT) and Modified Ashworth Scale (MAS) were performed at pre-training, post-training and three months follow-up. In comparing to other groups, The BCI-robotic group showed significant improvement after training in FMA full score (10.05 ± 8.03, p = 0.001), FMA shoulder/elbow (6.2 ± 5.94, p = 0.0004) and FMA wrist/hand (4.3 ± 2.83, p = 0.007), and WMFT (5.1 ± 5.53, p = 0.037). The improvement of FMA was significantly correlated with BCI accuracy (r = 0.714, p = 0.032). Recovery of hand function after rehabilitation of SSVEP-BCI controlled soft robotic glove showed better result than solely robotic glove rehabilitation, equivalent efficacy as results from previous reported MI-BCI robotic hand rehabilitation. It proved the feasibility of SSVEP-BCI controlled soft robotic glove in post-stroke hand function rehabilitation.
22 July 2019 in IEEE Robotics and Automation Letters
Soft robotic arms are receiving more and more attention for their intrinsic safety and natural compliance. Instead of traditional serialized rotary joints, soft robotic arms often have complex joints with coupled degrees of freedom like bending, rotation, and elongation, enabling them with more freedoms in achieving sophisticated movements. However, currently soft robotic arms are mostly focusing on bending and rotation, whereas elongation is either unavailable due to the inextensible backbone or only has a small range because of the limited contraction ratio of actuators. Furthermore, the coupling of actuators and complex structure makes the modeling and control hard. In this letter, we introduced an extensible soft robotic arm with a large elongation ratio of 400%, and give a novel modeling method from a new perspective of the force balance of the arm. The models were experimentally tested both in loaded and unloaded situations, showing the effectiveness of predicting the bending, rotation, and elongation of the arm.
A bionic robotic hand can perform many movements similar to a human hand. However, there is still a significant gap in manipulation between robot and human hands. It is necessary to understand the finger kinematics and motion patterns of human hands to improve the performance of robotic hands. This study aimed to comprehensively investigate normal hand motion patterns by evaluating the kinematics of hand grip and release in healthy individuals. The data corresponding to rapid grip and release were collected from the dominant hands of 22 healthy people by sensory glove. The kinematics of 14 finger joints were analyzed, including the dynamic range of motion (ROM), peak velocity, joint sequence and finger sequence. The results show that the proximal interphalangeal (PIP) joint had a larger dynamic ROM than metacarpophalangeal (MCP) and distal interphalangeal (DIP) joints. Additionally, the PIP joint had the highest peak velocity, both in flexion and extension. For joint sequence, the PIP joint moved prior to the DIP or MCP joints during flexion, while extension started in DIP or MCP joints, followed by the PIP joint. Regarding the finger sequence, the thumb started to move before the four fingers, and stopped moving after the fingers during both grip and release. This study explored the normal motion patterns in hand grip and release, which provided a kinematic reference for the design of robotic hands and thus contributes to its development.
The development of soft robotics owes much to the field of biomimetics, where soft actuators predominantly mimic the movement found in nature. In contrast to their rigid counterparts, soft robots offer superior safety and human–machine interaction comfort, particularly in medical applications. However, when it comes to the hand rehabilitation exoskeletons, the soft devices have been limited by size and material constraints, unable to provide sufficient tensile strength for patients with high muscle tension. In this paper, we drew inspiration from the muscle structure found in the tail of dragonflies and designed a novel central tendon-based bellows actuator. The experimental results demonstrated that the central tendon-based bellows actuator significantly outperforms conventional pneumatic bellows actuators in terms of mechanical output. The tensile strength of the central tendon-based bellows actuator exceeded that of pneumatic actuators more than tenfold, while adding only 2 g to the wearable weight. This finding suggests that the central tendon-based bellows actuator is exceptionally well-suited for applications demanding substantial pulling force, such as in the field of exoskeleton robotics. With tensile strength exceeding that of pneumatic bellows actuators, this biomimetic design opens new avenues for safer and more effective human–machine interaction, revolutionizing various sectors from healthcare to industrial automation.
Bionic robotic hand can perform many movements similar to human hand. But there is still a significant gap in manipulation between robot and human hand. It is necessary to understand the finger kinematics and motion patterns of human hand to improve the performance of robotic hand. This study aimed to comprehensively investigate normal hand motion patterns by evaluating the kinematics of hand grip and release in healthy individuals. The data corresponding to rapid grip and release were collected from the dominant hand of 22 healthy people by sensory glove. The kinematics of 14 finger joints were analyzed, including the dynamic range of motion (ROM), peak velocity, joint sequence and finger sequence. The results show that the proximal interphalangeal (PIP) joint had a largest dynamic ROM than metacarpophalangeal (MCP) and distal interphalangeal (DIP) joints. Besides, the PIP joint had the highest peak velocity, both in flexion and extension. For joint sequence, the PIP joint moved prior to the DIP or MCP joints during flexion, while extension started in DIP or MCP joints, followed by PIP joint. Regarding the finger sequence, the thumb started to move before four fingers, and stopped moving after the fingers during both grip and release. This study explored the normal motion patterns in hand grip and release, which provided kinematic reference for the design of robotic hand and thus contribute to its development.