A sensitive material consisting of silver/silver oxide decorated WO3 was successfully grown in two steps via aerosol-assisted chemical vapour deposition (AACVD). Morphological, structural, and composition analysis revealed our method is effective for growing WO3 nanoneedles decorated with silver/silver oxide nanoparticles at relatively low temperature (≤375°C) onto sensor arrays printed on alumina substrate. The sensors were tested for oxygen under humid environment (relative humidity ~85%) with the concentration ranging between 0% and 20%. Gas sensing results showed good response to oxygen with optimum temperature was observed at 400°C for undecorated WO3 and at 350°C for silver/silver oxide decorated WO3. The addition of silver/silver oxide was found to improve the sensor response by almost 300%, making the sensor a potential alternative to replace existing Pb-based oxygen sensor.
Platinum and palladium doped indium oxide sensors have been successfully fabricated by a screen printing method and tested as oxygen sensors at low temperature (150–400 °C) in a humid environment (~80–85% RH). The sensors, complying with a power law relationship, showed good differentiation at lower temperatures with highest response observed at 200 °C. Platinum had sensitivity of 2.2% per %O2 and power law exponent α = 0.72 vs. 0.3% per %O2 for palladium with power law exponent α = 0.51. Overall, the response of platinum doped indium oxide was higher than the palladium doped version.
In this paper we report on the development tungsten oxide based chemiresistive sensors for the monitoring of oxygen at low temperatures (T ≤ 400 °C) in dry and humid air. The sensors were deposited onto alumina substrate by a combination of spin coating and a photolithographic process to define the sensing area. Our results show that the sensors comply with a linear relationship over a 0 to 20% concentration range, with a high response towards oxygen. The highest response was observed at 350 °C (ΔR/Ra = 7.8) in humid and in dry air (ΔR/Ra = 18). This result is a significant improvement over our previous experiments and we believe to take the concept of a metal-oxide based oxygen sensor a step closer.
30 August 2023 in Journal of Educational Science and Technology (EST)
A flipped classroom is a pedagogical approach that reverses the traditional model of learning where students are provided with materials prior to class. Whereas reflective practice is an approach that encourages students to analyze their learning experiences and evaluate their progress in understanding course materials. The COVID-19 pandemic has challenged the traditional model of classroom instruction, leading to a shift in teaching and learning activities toward virtual/remote delivery methods. This study evaluates the flipped classroom approach and reflective practices in Engineering Drawing module. The participants consisted of first year engineering students (n=76). The result fo the study shows positive outcomes from using flipped learning and reflective practice. Students felt that the module provided them with an engaging and challenging learning experience, enhancing not only their technical skills but also their overall learning capabilities
Thick film indium oxide chemiresistive sensors decorated with PdO and PtO2 particles were investigated for oxygen detection under humid conditions (tested ranging from 20%–80% RH) across a temperature range of 50 °C to 400 °C. The PtO2-decorated In2O3 sensors demonstrated a significantly higher response to oxygen, showing a 500% increase at 200 °C compared to the PdO-decorated sensors (response values of 41 and 8, respectively). Tests in dry air were conducted to assess the effect of humidity on sensor performance, revealing a maximum response of 74 for PtO2-In2O3 at 400 °C, more than three times higher than the response of 22 for PdO-In2O3. Selectivity tests confirmed that the sensors responded more strongly to oxygen than to interfering gases. The integration of an active carbon cloth (ACC) filter effectively reduced interferences from isobutylene and ethylene, enhancing sensor’s selectivity. A comparison of both sensors demonstrated that PtO2-decorated In2O3 has greater potential as an alternative to existing Pb-based electrochemical oxygen sensors, particularly in humid environments.