Michel Gerboles

Dr. Michel Gerboles

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in Atmosphere
Verified
Journal Article
Open access
PDF file
FKFederico Karagulian
Federico Karagulian
MBMaurizio Barbiere
Maurizio Barbiere
Alexander KotsevAlexander Kotsev
Alexander Kotsev
LSLaurent Spinelle
Laurent Spinelle
MGMichel Gerboles
Michel Gerboles
ABAnnette Borowiak
Annette Borowiak
A growing number of companies have started commercializing low-cost sensors (LCS) that are said to be able to monitor air pollution in outdoor air. The benefit of the use of LCS is the increased spatial coverage when monitoring air quality in cities and remote locations. Today, there are hundreds of LCS commercially available on the market with costs ranging from several hundred to several thousand euro. At the same time, the scientific literature currently reports independent evaluation of the performance of LCS against reference measurements for about 110 LCS. These studies report that LCS are unstable and often affected by atmospheric conditions—cross-sensitivities from interfering compounds that may change LCS performance depending on site location. In this work, quantitative data regarding the performance of LCS against reference measurement are presented. This information was gathered from published reports and relevant testing laboratories. Other information was drawn from peer-reviewed journals that tested different types of LCS in research studies. Relevant metrics about the comparison of LCS systems against reference systems highlighted the most cost-effective LCS that could be used to monitor air quality pollutants with a good level of agreement represented by a coefficient of determination R2 > 0.75 and slope close to 1.0. This review highlights the possibility to have versatile LCS able to operate with multiple pollutants and preferably with transparent LCS data treatment.

1 August 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
LSLaurent Spinelle
Laurent Spinelle
MGMichel Gerboles
Michel Gerboles
MVMaria Gabriella Villani
Maria Gabriella Villani
Manuel AleixandreManuel Aleixandre
Manuel Aleixandre
FBFausto Bonavitacola
Fausto Bonavitacola
The performances of several field calibration methods for low-cost sensors, including linear/multi linear regression and supervised learning techniques are compared. A cluster of ozone, nitrogen dioxide, nitrogen monoxide, carbon monoxide and carbon dioxide sensors was operated. The sensors were either of metal oxide or electrochemical type or base on miniaturized infra-red cell. For each method, a two-week calibration was carried out at a semi-rural site against reference measurements. Subsequently, the accuracy of predicted values was evaluated for about three months using a few indicators and techniques: orthogonal regression, target diagram, measurement uncertainty and drifts over time of sensor predictions. The study assessed if the sensors can reach the Data Quality Objective (DQOs) of the European Air Quality Directive for indicative methods (between 25 and 30 % of uncertainty for O3 and NO2). In this study it appears that O3 may be calibrated using simple regression techniques while for NO2 better agreement between sensors and reference measurements was reached using supervised learning techniques. The hourly O3 DQO was met while it is unlikely that NO2 hourly one can be met. This was likely caused by the low NO2 levels correlated with high O3 levels that are typical of semi-rural site as where the measurements of this study took place.JRC.H.2-Air and Climat

28 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
LSLaurent Spinelle
Laurent Spinelle
MGMichel Gerboles
Michel Gerboles
GKGertjan Kok
Gertjan Kok
SPStefan Persijn
Stefan Persijn
Tilman SauerwaldTilman Sauerwald
Tilman Sauerwald
This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions.

18 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Alexander KotsevAlexander Kotsev
Alexander Kotsev
SSSven Schade
Sven Schade
MCMax Craglia
Max Craglia
MGMichel Gerboles
Michel Gerboles
LSLaurent Spinelle
Laurent Spinelle
MSMarco Signorini
Marco Signorini
The widespread diffusion of sensors, mobile devices, social media and open data are reconfiguring the way data underpinning policy and science are being produced and consumed. This in turn is creating both opportunities and challenges for policy-making and science. There can be major benefits from the deployment of the IoT in smart cities and environmental monitoring, but to realize such benefits, and reduce potential risks, there is an urgent need to address current limitations, including the interoperability of sensors, data quality, security of access and new methods for spatio-temporal analysis. Within this context, the manuscript provides an overview of the AirSensEUR project, which establishes an affordable open software/hardware multi-sensor platform, which is nonetheless able to monitor air pollution at low concentration levels. AirSensEUR is described from the perspective of interoperable data management with emphasis on possible use case scenarios, where reliable and timely air quality data would be essential.

26 May 2023 in Scientific Data
Verified
Journal Article
Open access
PDF file
MPMartine Van Poppel
Martine Van Poppel
PSPhilipp Schneider
Philipp Schneider
JPJan Peters
Jan Peters
SYSinan Yatkin
Sinan Yatkin
MGMichel Gerboles
Michel Gerboles
RHRolf Haugen
Rolf Haugen
Low-cost air quality sensor systems can be deployed at high density, making them a significant candidate of complementary tools for improved air quality assessment. However, they still suffer from poor or unknown data quality. In this paper, we report on a unique dataset including the raw sensor data of quality-controlled sensor networks along with co-located reference data sets. Sensor data are collected using the AirSensEUR sensor system, including sensors to monitor NO, NO2, O3, CO, PM2.5, PM10, PM1, CO2 and meteorological parameters. In total, 85 sensor systems were deployed throughout a year in three European cities (Antwerp, Oslo and Zagreb), resulting in a dataset comprising different meteorological and ambient conditions. The main data collection included two co-location campaigns in different seasons at an Air Quality Monitoring Station (AQMS) in each city and a deployment at various locations in each city (also including locations at other AQMSs). The dataset consists of data files with sensor and reference data, and metadata files with description of locations, deployment dates and description of sensors and reference instruments.

30 June 2011 in Atmospheric Environment
Verified
Journal Article
Closed access
MGMichel Gerboles
Michel Gerboles
DBD. Buzica
D. Buzica
Richard J C BrownRichard J C Brown
Richard J C Brown
RYR.E. Yardley
R.E. Yardley
AHA. Hanus-Illnar
A. Hanus-Illnar
JTJ. Turšič
J. Turšič