Sharmistha Bhadra

Dr. Sharmistha Bhadra

Integrated Circuits and Systems Group, Department of Electrical and Computer Engineering, McGill University, Montreal, QC, H3A 0E9, Canada

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
KSKiran kumar Sappati
Kiran kumar Sappati
Sharmistha BhadraSharmistha Bhadra
Sharmistha Bhadra
Polymers and papers, which exhibit piezoelectricity, find a wide range of applications in the industry. Ever since the discovery of PVDF, piezo polymers and papers have been widely used for sensor and actuator design. The direct piezoelectric effect has been used for sensor design, whereas the inverse piezoelectric effect has been applied for actuator design. Piezo polymers and papers have the advantages of mechanical flexibility, lower fabrication cost and faster processing over commonly used piezoelectric materials, such as PZT, BaTiO3. In addition, many polymer and paper materials are considered biocompatible and can be used in bio applications. In the last 20 years, heterostructural materials, such as polymer composites and hybrid paper, have received a lot of attention since they combine the flexibility of polymer or paper, and excellent pyroelectric and piezoelectric properties of ceramics. This paper gives an overview of piezoelectric polymers and papers based on their operating principle. Main categories of piezoelectric polymers and papers are discussed with a focus on their materials and fabrication techniques. Applications of piezoelectric polymers and papers in different areas are also presented.

31 July 2020 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
RRRobin Raju
Robin Raju
Greg E. BridgesGreg E. Bridges
Greg E. Bridges
Sharmistha BhadraSharmistha Bhadra
Sharmistha Bhadra

26 October 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
HAHossein Anabestani
Hossein Anabestani
SNSeyed Nabavi
Seyed Nabavi
Sharmistha BhadraSharmistha Bhadra
Sharmistha Bhadra
Future electronics will need to be mechanically flexible and stretchable in order to enable the development of lightweight and conformal applications. In contrast, photodetectors, an integral component of electronic devices, remain rigid, which prevents their integration into everyday life applications. In recent years, significant efforts have been made to overcome the limitations of conventional rigid photodetectors, particularly their low mechanical deformability. One of the most promising routes toward facilitating the fabrication of flexible photodetectors is to replace conventional optoelectronic materials with nanomaterials or organic materials that are intrinsically flexible. Compared with other functional materials, organic polymers and molecules have attracted more attention for photodetection applications due to their excellent photodetection performance, cost-effective solution-fabrication capability, flexible design, and adaptable manufacturing processes. This article comprehensively discusses recent advances in flexible organic photodetectors in terms of optoelectronic, mechanical properties, and hybridization with other material classes. Furthermore, flexible organic photodetector applications in health-monitoring sensors, X-ray detection, and imager devices have been surveyed.

8 January 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KSKiran kumar Sappati
Kiran kumar Sappati
Sharmistha BhadraSharmistha Bhadra
Sharmistha Bhadra
In this paper, Lead Zirconate-Titanate (PZT)/Polydimethylsiloxane (PDMS) based composite is fabricated and characterized for its potential application as a flexible piezoelectric material. Thin films of the composite are prepared by dispersing different volume percentage of PZT particles in cross-linked PDMS matrix. Corona poling of the films is performed to increase the piezoelectric charge constant. X-ray diffraction results indicate that poling aligns the randomly oriented ferroelectric domains in the PZT particles along the poling axis. Piezoelectric voltage response and piezoelectric charge constant values before and after the poling show the improvement in piezoelectricity due to poling. The piezoelectric charge constant, d33 and magnitude of relative permittivity of the films increase and flexibility of the films decrease with the increase of PZT particle volume percentage in the composite. Results show that for 28 v% PZT composite poled film a d33 of 78.33 pC/N was achieved with a Youngs modulus of around 10 MPa and magnitude of relative permittivity of 10. The film demonstrates effectiveness for tactile sensing by generating charges across the film proportional to the finger pressure applied on them. The easy fabrication process makes the composite a promising candidate to build flexible low cost tactile sensing devices.

2 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SNSeyedfakhreddin Nabavi
Seyedfakhreddin Nabavi
Sharmistha BhadraSharmistha Bhadra
Sharmistha Bhadra
Robustness of estimating cardiorespiratory parameters from photoplethysmography (PPG) signal is highly dependent on the quality of the signal, which heavily affected by motion artifacts. To increase the estimation accuracy of cardiorespiratory parameters, the present work describes a novel fusion method to efficiently and effectively reduce the motion artifacts from the acquired PPG signal. The proposed fusion technique requires simultaneously acquiring data from a PPG sensor and accelerometer. To filter out the frequencies associated with motion, the method uses stopband filters with a central rejection frequency and bandwidth determined by the output signal of the accelerometer. Under such, the proposed method to remove the motion artifacts does not depend on the quality of the reference signal and has almost no impact on the nature of PPG signals (i.e., amplitude, baseline, and periodicity). The effectiveness of the proposed method in the suppression of in-band and out-of-band frequencies of motion is numerically and experimentally evaluated. It is shown that the filtered PPG signal has sufficient information to estimate different cardiac parameters such as heart-rate (HR), respiration rate (RR) and blood oxygen saturation (SpO2). The motion artifacts free PPG signal obtained using our proposed method can estimate HR, RR, and SpO2 with an accuracy of above 95%. This level of accuracy confirms the usefulness of the proposed fusion method for accuracy improvement of cardiorespiratory parameters monitoring by the filtered PPG signal.

13 August 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
MNMehdi Nosrati
Mehdi Nosrati
ZAZahra Abbasi
Zahra Abbasi
MBMasoud Baghelani
Masoud Baghelani
Sharmistha BhadraSharmistha Bhadra
Sharmistha Bhadra
MDMojgan Daneshmand
Mojgan Daneshmand
This research study reports on a new coupling structure to demonstrate a constant coupling strength for longer distances in planar microwave sensors. It is shown that there is a positive correlation between the gap size in a pair of gap-coupled transmission lines (GCTLs) and the effective distance of reader and sensing resonators in a planar microwave sensor. On the other hand, the coupling strength in a pair of GCTLs is negatively correlated to the gap size between the two lines, where the larger gap sizes result in weaker coupling strength or vice versa. A technique is introduced to make the coupling strength partially independent of the gap size in GCTLs. The technique enables a sensor designer to increase the gap size, and subsequently, the distance between the reader and sensing resonators of a sensor. Strong electromagnetic coupling is locally demonstrated between a pair of GCTLs using a new artificial perfect electromagnetic conductor (PEMC) boundary, which does not allow electromagnetic power reflect toward the source over larger gap sizes in GCTLs. The concept is experimentally verified with a gap size up to 10 mm between GCTLs with a constantly measured insertion loss of 0.9 dB. Moreover, the structure is employed to design distant microwave resonator for humidity sensing applications. The design has demonstrated the ability of sensing, while the sensing resonator is placed at 35-mm distance from the readout circuitry. The structure is reported to increase the sensing distance with a ratio of about 12 (36:3) compared to the conventional microwave sensors.