Efficient and scalable production of two-dimensional (2D) materials is required to overcome technological hurdles towards the creation of a 2D-material-based industry. Here, we present a novel approach developed for the exfoliation of layered crystals, i.e., graphite, hexagonal-boron nitride and transition metal dichalcogenides. The process is based on high-pressure wet-jet-milling (WJM), resulting in a 2 L h−1 production of 10 g L−1 of single- and few-layer 2D crystal flakes in dispersion making the scaling-up more affordable. The WJM process enables the production of defect-free and high quality 2D-crystal dispersions on a large scale, opening the way for their full exploitation in different commercial applications, e.g., as anode active material in lithium ion batteries, as reinforcement in polymer–graphene composites, and as conductive inks, as we demonstrate in this report.
The crystal structure of graphene flakes is expected to significantly affect their sensing properties. Here we report an experimental investigation on the crystalline structure of graphene aimed at exploring the effects on the gas sensing properties. The morphology of graphene, prepared via Chemical Vapor Deposition (CVD), Liquid Phase Exfoliation (LPE) and Mechanical Exfoliation (ME), is inspected through Raman spectroscopy, Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM). CVD and LPE-graphene structures are found to be more defective with respect to ME-graphene. The defects are due to the jagged morphology of the films rather than originating from intrinsic disorder. The flatness of ME-graphene flakes, instead, explains the absence of defects. Chemiresistors based on the three different graphene preparation methods are subsequently exposed to NO2 in the concentration range 0.1–1.5 ppm (parts per million). The device performance is demonstrated to be strongly and unambiguously affected by the material structure: the less defective the material is, the higher the response rate is. In terms of signal variation, at 1.5 ppm, for instance, ME-graphene shows the highest value (5%) among the three materials. This study, comparing simultaneously graphene and sensors prepared via different routes, provides the first experimental evidence of the role played by the graphene level of defectiveness in the interaction with analytes. Moreover, these findings can pave the path for tailoring the sensor behavior as a function of graphene morphology.
Here, we present a room temperature operating chemi-sensor based on a graphene film that shows sensitivity to NO2 up to a 50 parts-per-billion (ppb) with extremely limited interference from relative humidity and can be also calibrated in a sub-parts-per-million (ppm) range with a response and recovery time of few seconds. The device has been fabricated using as active material, a solution of graphene nanosheets suspended in N-methyl-pyrrolidone drop casted on an alumina substrate with gold interdigitated electrodes. The derivative of the device response is found to be univocally correlated to NO2 concentrations from 100 ppb up to 1000 ppb and the sensor can therefore be calibrated in this same range.
1 February 2017 in Sensors and Actuators B: Chemical